1 / 53

MBI Phase Shifters

MBI Phase Shifters. Or A Tale of Two Weeks. Amanda Gault April 12, 2005. Outline. Why do we need phase shifters? How does it work? What tests do we do? What preparation for tests? What results? What we still need to know?. What is a Phase Shift?. Why.

pegeen
Download Presentation

MBI Phase Shifters

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MBI Phase Shifters Or A Tale of Two Weeks Amanda Gault April 12, 2005

  2. Outline • Why do we need phase shifters? • How does it work? • What tests do we do? • What preparation for tests? • What results? • What we still need to know?

  3. What is a Phase Shift?

  4. Why • To pick individual baselines out of the combined signal • To isolate the sky signal from noise

  5. Faraday Rotators • Utilize a superconducting solenoid and ferrite to rotate the plane of polarization of the incoming signal • Rotation depends on current through device

  6. input Rotate -90 output input Rotate +90 output Waveguide orientations

  7. Assembly

  8. Testing • Want to determine: • Maximum current • Reflection and transmission coefficients • Maximum Rotation

  9. Testing: Maximum Current • Tests at San Diego show phase varying nearly linearly with current • Reach a max rotation angle of ~75 degrees • We need a 90 degree rotatiokn • If we can get a higher max current, we can increase the rotation

  10. Testing: Coefficients • Utilizing the Vector Network Analyzer in Engineering, we can measure the amount of signal which is transmitted and reflected through our system • Reflection measurements are S11 and S22 • Transmission measurements are S12 and S21 • Ideally want all of the signal transmitted

  11. Testing • Since the Faraday Modulator relies on superconductivity, it must be cold (<9K) to operate • Had to fit it into a test dewar

  12. Waveguide Plumbing

  13. A very tight fit

  14. Applying lots of pressure

  15. Sealed leak with apiezo

  16. Resistance through phase shifter Keeping track of time, pressure, resistance, and temperature Thermometer readout

  17. First Test • Leak • sealed with goop • Would phase shifter would not go below 11K • Difficulty filling liquid Helium • Unable to test at VNA since temperature did not get down far enough • Needed better heat-sinking

  18. Prep for Second Test • Improved Heat-sinking • Added more short, thick pieces of copper connecting from the cold plate closer to the phase shifter • Rewired so that the brass wires connect to copper post on cold plate before connecting to the phase shifter • Damaged Thermometer

  19. Tightening down the new pieces of copper

  20. Original heat sinking Thermometer Post with wires New wires to adapt from brass to those on the phase shifter New heat sinking pieces

  21. Same room temperature resistance before and after rewiring

  22. Second cool down Towel Leaking funnel

  23. Filling liquid Helium

  24. Since Thermometer was damaged, relied on the changing resistance of the Faraday Modulator to estimate temperature • Cooled far enough for it to become superconducting • Carefully set it up at Engineering

  25. Aligning the ports of the VNA

  26. Highly accurate leveling system

  27. Instruction on how to properly connect and tighten to the VNA ports

  28. Complete set-up VNA display Ammeter and voltmeter VNA ports Power supply

  29. Results • S12 and S21 measurements not identical • Probably at least partially due to slight twisting to fit set up into dewar • Assuming a cos2(θ) angular dependence, the Faraday Modulator gave a maximum rotation of about 25°.

  30. Conclusion • Still not sure if the Faraday Modulator will perform as we need it to • Even better heat sinking needed • Will be testing another phase shifter designed by an engineering student here • The gold dewar is the Precious