290 likes | 402 Views
Freelance 2000. ABB Automation. ABB-1408 Page 1. Digi Vis. DigiTool. Ethernet. Process station. SYSTEM ARCHITECTURE OF STANDALONE AC800F SYSTEM. AI 801. AI 801. AI 801. AI 801. AI 801. AI 801. AI 801. AI 801. AI 801. AI 801. AI 801. AI 801. AI 801. AI 801. AI 801. AI 801.
E N D
Freelance 2000 ABB Automation ABB-1408 Page 1
Digi Vis DigiTool Ethernet Process station SYSTEM ARCHITECTURE OF STANDALONE AC800F SYSTEM
AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 ENGG /OPERATOR STATION OPERATOR STATION HUB 01 HUB 02 SA801F EI801F EI801F FI830F SPARE SPARE SPARE SA801F EI801F EI801F FI830F SPARE SPARE SPARE C I 8 3 0 C I 8 3 0 EXAMPLE OF A SIMPLE SYSTEM
AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 SPARE Small System 100..250 I/O ENGG /OPERATOR STATION PM 802F SA801F EI801F FI830F SPARE SPARE SPARE C I 8 3 0 C I 8 3 0
Small System with modbus interface AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 AI 801 SPARE ENGG /OPERATOR STATION PM 802F FI820F SA801F EI801F FI830F SPARE SPARE C I 8 3 0 PROFIBUS Modbus C I 8 3 0
ControlIT AC 800F: Hardware • AC 800F • Modular and flexible concept, DIN-rail mounted • Hot swap of Fieldbus module • Fieldbus I/O options • CAN • Profibus • FF • Modbus (Master & Slave) • Industry quality hardware with Redundancy
Modules are Hot Swappable • Moving the cover of the upper screw will signal the planned removal to the CPU. • CPU will shut down the bus gracefully and switch off the power for the module • Module may then be removed
Power Supply Module (SD 802F /SA 801F) Available types: • 115/220V AC (SA 801F) • 24V DC with redundant input (SD 802F) (range 18...36 V DC) Serial Interface for CPU- Diagnostics
Ethernet Module (EI 80xF) Physical layer selectable by Module. Available Types: • 10Base2 (EI 801F) • AUI (EI 802F) • 10 BaseTX (EI 803F) • 10/100 Base TX (in prep.) Status LED for Ethernet Diagnostics (correct termination, ...) Battery provides Confi-Backup in case of Power outage Selector Switchfor IP-Address setting
Profibus Module (FI 830F) • Profibus DP V1 • up to 12 Mbps • Master ‘Class 1 & 2’ • ‘Single Master Mode’ext. Master Class 2 allowed • Line Redundancy by external Hardware Box RLM01 • Profibus PA by DP/PA-Converter • Hot swappable
Serial Interface Module (FI 820F) • 2 Ports • RS485/422/232C • Modbus Protocol (Master & Slave)
AC 800F Process I/O • I/O • DIN rail mounting • Flexible field termination • Automatic slot addressing • Outputs go to a predetermined value in the event of a malfunction • Hot swap of modules and power supply • Modern and rugged design
HOW FREELANCE IS EASY FOR USE Powerful 32-bit digital and analog processing Fully redundant A single, system wide (global) database A single tool for configuring automation and operator interfaces Graphic configuration development using (function block diagram, ladder logic diagram, instruction list and sequential flow chart)
HOW FREELANCE IS EASY FOR USE Windows NT interface Best system diagnostics . On-line or Off-line configuration . System-wide logic & graphical documentation
Operation and Observation with DigiVis • What’s DigiVis? • Benefits of predefined graphics • Reliable Operation ABB Automation Inc. F2K_V51news_e. ppt Page 9
What is DigiVis? • DigiVis is your Window to the Process: • Easy Operation & Diagnostics of the entire system • Easy to configure: 3D Libraries available • Easy Access: Quickselect Window & shortcuts • Configuration & Commissioning through DigiTool • Using Standard PC ABB Automation Inc. F2K_V51news_e. ppt Page 9
DigiVis Overview • Reliable Operation • Standard and free graphic displays with Bitmap • Clearly structured hierarchies for quick selection of tags • Context sensitive menus • A consistent message concept 8 priorities and 15 plant areas • Access control with 16 user profiles & 1,000 users • Browsing online as well as on historical trends and logs • Windows NT 4.0 based ABB Automation Inc. F2K_V51news_e. ppt Page 9
Predefined Displays Alarm line System Display Overview Display (Module Diagnostics) (Table of Contents) Group Display Faceplate(Access on Tags) Time scheduler- Trend Display Display (Data Historian) SFC Display Criteria window(SFC-Step completed?) Event list List of hints(Help, What shall I do?) ABB Automation Inc. F2K_V51news_e. ppt Page 9
Overview Display • Alarm line can never be covered, always on the top area of the screen • Operator panel always on the bottom of screen • Windows Menu bar • Direct access to all important displays • Animated ABB Automation Inc. F2K_V51news_e. ppt Page 9
OPERATOR STATION DIGIVIS OPERATOR CONFIGURABLE QUICK SELECTION KEY
Alarm Management • Consistent message strategy for all operator consoles: • Message/Alarm Line • Message List • Operator Hints • 8 Priority Levels- Colors- Acknowledgement • 15 Plant Areas • Direct Access to tags • Faceplate Call-up and Operation • individual Sound files for Alarms ABB Automation Inc. F2K_V51news_e. ppt Page 9
Graphic Display Select Buttons ABB Automation Inc. F2K_V51news_e. ppt Page 9
Graphic Displays Dynamic Objects • Bargraph/ Fill area • Trend window • Alphanumeric Display • Button (Switch, Display Selection) • Graphic symbol • Self animated Objects ABB Automation Inc. F2K_V51news_e. ppt Page 9
System Display • Inbuild System diagnostics • Different colors for system states(Module Type, Status, Temperature, Forced Channels) • Additional Diagnostic level for technicians (Runtime, CPU-Load, ...) ABB Automation Inc. F2K_V51news_e. ppt Page 9
Logging • Signal Sequence Log • Events and Process Changes • Operator Interventions • Hints • System • Plant / Operation Log • Manually or Event Driven • Record Specific Values • Disturbance Course Log • Record of Measured Variables Before and After Defined Event ABB Automation Inc. F2K_V51news_e. ppt Page 9
Trend of Variables • Unlimited amount of Trends per DigiVis Operator Station • Without Trend Acquisition Blocks ABB Automation Inc. F2K_V51news_e. ppt Page 1