1 / 28

Home

Home. EMC/EMI and RF Instrumentation. EMC Compliance systems. and. EMC Pre-Compliance systems. and. RF monitors and meters. Emissions. Immunity. Harmonics & Flicker. Safety at work. EN series Def Stan FCC As/Nz. IEC61000-3-2 IEC61000-3-3. ICNIRP. IEC61000-4-series.

pello
Download Presentation

Home

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Home EMC/EMI and RF Instrumentation EMC Compliance systems and EMC Pre-Compliance systems and RF monitors and meters Emissions Immunity Harmonics & Flicker Safety at work EN series Def Stan FCC As/Nz IEC61000-3-2 IEC61000-3-3 ICNIRP IEC61000-4-series All from the Experts at Laplace Instruments Ltd

  2. Selector So what do you require? Make emissions measurements to check emission compliance? Test for susceptibility/immunity? Or both? Test for Harmonics & Flicker compliance? Looking for ancillaries such as reference sources, antennas, LISNs etc…..? See the overview and selector chart

  3. Routemap EMC Compliance Testing – the essential guide Emissions Susceptibility (immunity) Harmonics & Flicker RFG- core system SA1000 (1GHz) or SA3000 (3GHz) analyser IEC61000-4-3 IEC61000-4-2,4,5,11 IEC61000-4-6 Radiated RF LF effects Conducted RF RF100 probes SA1020 pre-amp IEC61000-3-2 IEC61000-3-3 RF1000 (1GHz) or RF2000 (2GHz) or RF3000 (3GHz) Synthesiser Conducted Radiated RFIC-46 All EMC emission standards Appliance? EN55014 RF Absorbing clamp AC2000 analyser CDNs RF11xx, RF12xx or RF13xx Power Amplifiers LISN or PLIP Luminaire? EN55015 RF300 large Loop antenna AC1000 clean Power source If emissions Broadband? All other EMC standards ECOMPACT4 Integrated test system Key LETIS RF800 or RF910 or RF915 Pre-selector Information RF200 RF230 antenna EUT size……… Large and small or Small? CDNs Laplace product ESD Test cell Lc300/2 or Lc600 30MHz – 3GHz Incl PC software RF200, RF230 or CTS011 miniature antenna Clamps Incl. in CLIENTS Filtered feeds Camera & lighting Loops RF600 and RF700 Ambient filters Anechoic chamber LETIS OATS Anechoic chamber RFP-04CE Field probe +fibre link option ERS Emissions Reference Sources

  4. H & F HARMONICS & FLICKER Compliant with: IEC61000-3-2 IEC61000-3-3 Now updated to the latest versions of the standards, including IEC61000-4-7 and IEC61000-4-15 AC2000A Harmonic & Flicker analyser. Features: Automatic testing Automatic calculation of ‘variable’ limits Self contained instrument PC interface included AC1000A Clean power source. Provides up to 1kW (4A) of pure sine mains power. Output harmonic content: <0.1% THD

  5. Emission selector Emissions………… Emissions analyser ? Radiated – test cell or Conducted Radiated – Antenna Radiated – Large Loop Antenna Radiated – Reference sources Radiated – Pre-amplifier Radiated – Near field probes

  6. Conducted selector Conducted emissions Analyser and software LISNs Voltage probes

  7. SA1000-a EMC analysers and software High performance EMC analysers……. SA1002…………9KHz – 1GHz SA3000…………9KHz – 3GHz Compliant detectors (Pk, QP and Average) Pre-loaded limits in software. All results in Windows environment. Easy to use…. USB interface to any PC Input connects to any Laplace antenna or transducer. See also the RF910 and RF915 pre-selectors. Conducted Radiated Pre-selector Antennas LISNs Test Cell Voltage probes Reference sources

  8. Cells Test cells It does not get any easier than this……….. * Quick * Compact * Convenient Radiated Emissions to 3GHz Radiated Immunity to 3GHz Two sizes:……. Lc300/2: up to 30cm cube EUT, benchtop model Lc600: up to 60cm cube EUT, floor standing Both provide IEC61000-4-3 testing to over 10V/m Emissions Select or Immunity More details……

  9. Lc300/2-outer Access door open to EUT area Lc300/2 • System configured with: • SA1000 emissions analyser • RF2000 synthesiser • RF1100 power amplifier • LETIS • RF1200 power amplifier More details……

  10. Lc300/2-filter Lc300/2 Filter connection plate to External services Access door open to internal filter connections. Aperture (hidden) provides access to EUT volume More details……

  11. Cellnotes • Advantages of test cells • Eliminate ambient • Known calibration • Compact size • Ease of use • Located in your own lab. • Convenience • Not dependant on the weather! • Advantages specific to LaplaCell • Smallest size • Better field uniformity GTEM field - poor uniformity LaplaCell field - far better uniformity • Impedance matched for better results • Free space impedance is 377ohm (Ideal) • GTEM cells are 50ohm systems • Laplacell features impedance conversion to 200ohm • Much closer to ideal • Complies with IEC61000-4-20 • Latest standard for the calibration of cells • Built-in field sensor • Save cost and complexity Test chamber option

  12. Test chamber Integrated system for immunity testing to IEC61000-4-3 in test chamber RF200 and RF230 antennas Field sensor (RFP-04CE) With RS232 fibre optic interface (PCLK) Chamber Optional EUT monitoring Fibre optic cable (FOLK) EUT Antenna Synthesiser/ signal genny System controller Power amplifier Switch Unit System software RF11xx RF12xx or RF1300 LETIS RF1000, RF2000 or RF3000 with –RH option (External sensor)

  13. RF910 Pre-selector units RF910 and RF915 As specified by CISPR16 and recommended for conducted emission measurements if the EUT produces broadband noise. These pre-selectors effectively pre-filter the incoming signal such that the analyser input is not overloaded by broadband energy. Not required if EUT produces narrowband noise. RF910 covers band B (150KHz – 30MHz) RF915 covers bands A and B (9KHz – 30MHz) RF1000 or RF2000 Photo shows RF910 below SA1000 and PC

  14. ERS Emissions Reference Sources These sources can be used to simply check an established site prior to measurements, or To calibrate an unknown site. Note that the dominant source of measurement uncertainty for radiated emissions is the test site! ERS 1GHz reference source Fully traceable to NPL 2MHz spacing Provides auto site calibration when used with SA1002 or SA3000 EMC3.5 3.5GHz reference source. Extremely compact Only 12 x 7 x 14cm 10 or 50MHz spacing Remote control option

  15. Antennas ARA Active receive antenna Compact, but same sensitivity as larger antenna A range of antennas to cover most requirements. Antennas RF300 Large loop antenna (Van Leen Loop) To CISPR15 CTS011 RF200 Broadband antenna 30MHz – 1GHz Standard EMC antenna For use on OATS or in test chambers Very small! About the size of your hand. For use in confined spaces

  16. Trifield RF meters and detectors TDM-200 RF power density meter. Internal antenna Ideal for RF signal strength field surveys. 0.5MHz to 3GHz TBM-100 Broadband meter An Electric field meter, Gaussmeter and RF field strength meter all in one small unit. Monitor and measure the field from AC power lines, video displays, ovens, LANs and mobile phones Gaussmeter: 40Hz –500Hz Electric field meter: 40Hz – 100KHz RF field meter: 100KHz – 2.5GHz T-MA-P Personal RF hazard warning detector Provides an audible warning if the RF field is close to the ICNIRP recommended limits Essential for all who work close to RF transmittersand cell base stations

  17. LISN LISNs and Voltage Probes LISN - Line Impedance Stabilisation Network Commercial range complies with CISPR16 Def Stan, Mil Spec and CISPR25 versions also available Up to 4 lines Up to 100A/phase Commercial range includes transient limiters PLIP Voltage probe As specified by CISPR16 For use when LISN is not appropriate. Includes opto-isolation and high voltage, fused connecting clips

  18. Immunity selector Immunity testing RFIC systems ECOMPACT4 Standard system LaplaCell systems

  19. RFI test-a RF Immunity test IEC61000-4-3 requires EUT to be immersed in strong modulated RF fields over the range 80MHz – 1GHz, or higher! The specified techniques are fully incorporated into The Laplace test system comprising a LaplaCell, system controller and power amplifier. SeeCLIENTS for total automated solutions. Note that these systems work equally well with test chambers (FAC or SAC or stirred mode). USB Any standard PC RF1000, RF2000 or RF3000 RF1100 and/or RF1200 or RF1300 EUT Feedback RF Power RF level feedback

  20. RF100 & SA1020 Pre-amp & near field probes RF100 near field probe set Essential tool for the location of emission sources and identification of emission frequencies. SA1020 Pre-amplifier 20dB gain, flat characteristic from 9KHz to over 1GHz. Internal PP3 battery provides 30 hour run time.

  21. CIT-10 Compact Immunity Test System Model RFIC46 Includes: Function generator Signal Generator RF Millivoltmeter RF power amplifier EUT monitoring Feedback monitoring IEC61000-4-6 Wide range of optional ‘Versatile’ and ‘Enhanced’ CDNs available • PC Controlled via USB • Windows software included • 100KHz – 300MHz (Exceeds requirements of the standard • 25W power amplifier… more than enough for most applications • Totally integrated system… very quick and easy to use.

  22. CLIENTS CLIENTS Combined Low costImmunity and EmissioNs Test Systems. System shown will provide automated measurements of emissions and RFI testing up to 2GHz. The LETIS (Laplace EMC Test Integration System) provides all necessary interconnections and switching under software control. Any standard PC SA1002orSA3000 Emissions analyser Immunity controller RF2000 30-1000MHz P.A. RF1100 System integrator LETIS 0.8-2GHz P.A. RF1200

  23. Power amps RF Power Amplifiers A range of RF power amplifers for use with test cells RF1100 25W 30MHz to 1GHz RF1170 70W 30MHz to 1GHz RF1200 12W, 0.8GHz to 2GHz RF1240 40W, 0.8GHz to 2GHz RF1300 10W, 0.8GHz to 3GHz These amplifiers will provide well in excess of the required fields for IEC61000-4-3 industrial standards inside the LaplaCells

  24. Synthesiser Immunity test controllers RF1000, 30MHz – 1GHz RF2000, 30MHz – 2.2GHz RF3000, 30MHz – 3GHz • Functions: • Signal generation and control • Field strength level control • EUT monitoring • Windows interface via USB • Flexible test setup • Full recording and display of results • Serial interface for remote sensor These controllers will provide all control and interface requirements for sophisticated immunity testing to IEC61000-4-3.

  25. Letis Power Laplace Instruments Ltd EMISSIONS IMMUNITY 1 2 RF1200 connections RF1100 connections RF connection to cell To emissions analyser To RF2000 Range 2 Manual Range select Range 1 Auto Made in UK LETIS - Laplace EMC Test Integration System LETIS Laplace EMC Test Integration System. RS232 LETIS acts as a PC controlled switching unit to automatically route the signals between the cell, the power amplifiers and the system controller. Avoids mistakes, saves time and allows long term unattended operation. Control USB To PC To Cell USB RF

  26. SA1000-b EMC analysers and software High performance EMC analysers……. SA1002…………9KHz – 1GHz SA3000…………9KHz – 3GHz Compliant detectors (Pk, QP and Average) Pre-loaded limits in software. All results in Windows environment. Easy to use…. Serial interface to any PC. Input connects to any Laplace antenna or transducer. See also the RF910 and RF915 pre-selectors. Conducted Radiated Pre-selector Antennas LISNs Test cell Voltage probes Reference sources

  27. RFI test-b RF Immunity test IEC61000-4-3 requires EUT to be immersed in strong modulated RF fields over the range 80MHz – 1GHz. The specified techniques are fully incorporated into The Laplace test system comprising a LaplaCell, system controller and power amplifier. SeeCLIENTS for total automated solutions. Note that these systems work equally well with test chambers (FAC or SAC or stirred mode). USB Any standard PC RF1000 or RF2000 or RF3000 RF1100 and/or RF1200 or RF1300 EUT Feedback RF Power RF level feedback

  28. Laplace About Laplace…. • Founded in 1988 • Specialises in EMC test equipment • NOT linked to any other company • Customer base worldwide • Global distributor network • Over 2000 EMC test systems in operation • Over 50 LaplaCell systems sold. • All main products and software developed in-house • We ALWAYS support all our customers direct… regardless of age of system (and all free of charge!) • Continuous development program… new hardware and software to match developments in standards Join the experts!

More Related