1 / 43

Scoreboarding & Tomasulo’s Approach

Scoreboarding & Tomasulo’s Approach. Bazat pe slide-urile lui Vincent H. Berk. Scoreboarding.     . Integer unit. FP add. FP divide. FP mult. FP mult. Scoreboard. Figure A.51 The basic structure of a DLX processor with a scoreboard. Scoreboard. Registers.

pello
Download Presentation

Scoreboarding & Tomasulo’s Approach

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Scoreboarding & Tomasulo’s Approach Bazat pe slide-urile lui Vincent H. Berk

  2. Scoreboarding

  3.     Integer unit FP add FP divide FP mult FP mult Scoreboard Figure A.51 The basic structure of a DLX processor with a scoreboard Scoreboard Registers Data buses Control/status Control/status

  4. 1. Issue: decode instructions & check for structural hazards (ID1) If a functional unit for the instruction is free and no other active instruction has the same destination register (WAW), the scoreboard issues the instruction to the functional unit and updates its internal data structure. If a structural or WAW hazard exists, then the instruction issue stalls, and no further instructions will issue until these hazards are cleared. Algorithm: Assure In-Order issue Multiple issues per cycle are allowed Check if Destination Register is already reserved for writing (WAW) Check if Read-Operand stage of Functional Unit is free (Structural) Four Stages of Scoreboard Control: ISSUE

  5. Four Stages of Scoreboard Control:READ-OPERANDS • Read operands: wait until no data hazards, then read operands (ID2) – First Functional Pipeline Stage A source operand is available if no earlier issued active instruction is going to write it, or if the register containing the operand is being written by a currently active functional unit. When the source operands are available, the scoreboard tells the functional unit to proceed to read the operands from the registers and begin execution. The scoreboard resolves RAW hazards dynamically in this step, and instructions may be sent into execution out of order. Algorithm: • Wait for operands to become available, Register Result Status (RAW) • Operand Caching is allowed • Forwarding from another WB stage is allowed

  6. Four Stages of Scoreboard Control – ex + write 3. Execution: operate on operands (EX) • The functional unit begins execution upon receiving operands. When the result is ready, it notifies the scoreboard that it has completed execution. This stage can be (sub-)pipelined. 4. Write result: finish execution (WB) • Once the scoreboard is aware that the functional unit has completed execution, the scoreboard checks for WAR hazards. If none, it writes results. If WAR, it stalls the instruction. Algorithm: • Delay write until all Rj and Rk fields for this register are marked as either cached or read. • If caching of operands is done: forward answer right away. • If not, wait until all operands are read before writing. • Forward answers to units waiting for this write for their operand.

  7. Three Parts of the Scoreboard 1. Instruction status • Indicates which of 4 steps the instruction is in. 2. Functional unit status • Indicates the state of the functional unit (FU). 9 fields for each functional unit • Busy – Indicates whether the unit is busy or not • Op – Operation to perform in the unit (e.g., + or -) • Fi – Destination register • Fj, Fk – Source-register numbers • Qj, Qk – Functional units producing source registers Fj, Fk • Rj, Rk – Flags indicating when Fj, Fk are available and not yet read.(Alternatively: read and cached) • Register result status: • Indicates which functional unit will write each register, if one exists. Blank when no pending instructions will write that register.

  8. Scoreboard Example Cycle 1 R2 has not been read/cached until cycle 2!!!

  9. Scoreboard Example Cycle 2 Issue 2nd LD or MULT?

  10. Scoreboard Example Cycle 4 Yes

  11. Scoreboard Example Cycle 5 SUPERSCALAR: Issue MULTD?

  12. Scoreboard Example Cycle 6

  13. Scoreboard Example Cycle 7 Read multiply operands? DIVD could have been issued on this cycle.

  14. Scoreboard Example Cycle 8a

  15. Scoreboard Example Cycle 8b

  16. Scoreboard Example Cycle 9 Issue ADDD?

  17. Scoreboard Example Cycle 11

  18. Scoreboard Example Cycle 12

  19. Scoreboard Example Cycle 13

  20. Scoreboarding Summary • Limitations of CDC 6600 scoreboard • No forwarding hardware • Limited to instructions in basic block (small window) • Small number of functional units (structural hazards), especially integer/load/store units • Do not issue if structural or WAW hazards • Wait for WAR hazards • Imprecise exceptions • Key idea: Allow instructions behind stall to proceed • Decode  issue instructions and read operands • Enables out-of-order execution  out-of-order completion

  21. Scoreboarding Summary • Modern Day Improvements: • All operands are cached as soon as available • Forwarding • Pipelining Functional Units • Microcoding, eg. IA32 (widens execution window) • More precise exceptions • In order retirement • Works best with tons of actual registers • Tomasulo approach: • Reservation stations vs. Forwarding and Caching • Temporary Registers work as many virtual registers

  22. Tomasulo’s Approach

  23. Hardware Schemes for ILP Key idea: Allow instructions behind stall to proceed Decode => issue instructions and read operands Enables out-of-order execution => out-of-order completion Why in hardware at run time? Works when dependence is not known at run time Simplifies compiler Allows code for one machine to run well on another Out-of-order execution divides ID stage: Issue — decode instructions, check for structural hazards Read operands — wait until no data hazards, then read operands

  24. Tomasulo’s Algorithm For IBM 360/91 about 3 years after CDC 6600 Goal: High performance without special compilers Differences between IBM 360 & CDC 6600 ISA IBM has only 2 register specifiers/instruction vs. 3 in CDC 6600 IBM has 4 FP registers vs. 8 in CDC 6600 Differences between Tomasulo’s Algorithm & Scoreboard Control & buffers (called “reservation stations”) distributed with functional units vs. centralized in scoreboard Registers in instructions replaced by pointers to reservation station buffer HW renaming of registers to avoid WAR, WAW hazards Common data bus (CDB) broadcasts results to functional units Load and stores treated as functional units as well Alpha 21264, HP 8000, MIPS 10000, Pentium III, PowerPC 604, ...

  25. Three Stages of Tomasulo Algorithm 1. Issue: Get instruction from FP operation queue If reservation station free, issues instruction & sends operands (renames registers). 2. Execution: Operate on operands (EX) When operands ready then execute; if not ready, watch common data bus for result. 3. Write result: Finish execution (WB) Write on common data bus to all awaiting units; mark reservation station available. Common data bus: data + source (“come from” bus)

  26. Tomasulo Organization From Instruction Unit FP Registers From Memory Load Buffers FP Op Queue Store Buffers Operand Bus To Memory Operation Bus FP Add Res. Station FP Mul Res. Station Reservation Stations FP Adders FP Multipliers Common data bus (CDB)

  27. Reservation Station Components Op – Operation to perform in the unit (e.g., + or – ) Qj, Qk – Reservation stations producing source registers Vj, Vk – Value of source operands Rj, Rk – Flags indicating when Vj, Vk are ready Busy – Indicates reservation station and FU is busy Register result status Indicates which functional unit will write each register, if one exists. Blank when no pending instructions will write that register.

  28. Tomasulo Example Cycle 1

  29. Tomasulo Example Cycle 2 ENGS 116 Lecture 8 29

  30. Tomasulo Example Cycle 3 Register names are renamed in reservation stations Load1 completing — who is waiting for Load1?

  31. Tomasulo Example Cycle 4 Load2 completing — who is waiting for it?

  32. Tomasulo Example Cycle 5

  33. Tomasulo Example Cycle 6

  34. Tomasulo Summary Reservation stations: renaming to larger set of registers + buffering source operands Prevents registers as bottleneck Avoids WAR, WAW hazards of scoreboard Allows loop unrolling in HW Not limited to basic blocks (integer units get ahead, beyond branches) Lasting Contributions Dynamic scheduling Register renaming Load/store disambiguation 360/91 descendants are Pentium III; PowerPC 604; MIPS R10000; HP-PA 8000; Alpha 21264

  35. Tomasulo with Speculation • Issue – Empty reservation station and an empty ROB slot. Send operands to reservation station from register file or from ROB. This stage is often referred to as: dispatch • Execute – Monitor CDB for operands, check RAW hazards. When both operands are available, then execute. • Write Result – When available, write result to CDB through to ROB and any waiting reservation stations. Stores write to value field in ROB. • Commit – Three cases: • Normal Commit: write registers, in order commit • Store: update memory • Incorrect branch: flush ROB, reservation stations and restart execution at correct PC

  36. Now, for the grand finale Let’s compare!!!

  37.     Integer unit FP add FP divide FP mult FP mult Scoreboard Figure A.51 The basic structure of a DLX processor with a scoreboard Scoreboard Registers Data buses Control/status Control/status

  38. Tomasulo Organization From Instruction Unit FP Registers From Memory Load Buffers FP Op Queue Store Buffers Operand Bus To Memory Operation Bus FP Add Res. Station FP Mul Res. Station Reservation Stations FP Adders FP Multipliers Common data bus (CDB)

  39. Scoreboard Example Cycle 6

  40. Tomasulo Example – cycle 6

  41. Control & buffers (“reservation stations”) distributed with functional units Registers in instructions replaced by pointers to reservation station buffer HW renaming of registers to avoid WAR, WAW hazards Common data bus (CDB) broadcasts results to functional units Load and stores treated as functional units as well Stages: Issue, Execution, Write result Control & buffers centralized Use actual registers Do not issue if structural or WAW hazards Wait for WAR hazards Forwarding? Stages: Issue, Read operands, Execution, Write result Differences between Tomasulo’s Algorithm & Scoreboard

More Related