460 likes | 769 Views
Advantys ETB Ethernet IP67 I/O. Advantys ETB. Introducing Schneider Electric’s new family of IP67 rated I/O modules that connect to Ethernet. Advantys ETB Ethernet IP67 I/O modules. Direct connection to the Ethernet network with models that support: Ethernet Modbus TCP/IP Protocol
E N D
Advantys ETB Introducing Schneider Electric’s new family of IP67 rated I/O modules that connect to Ethernet.
Advantys ETBEthernet IP67 I/O modules • Direct connection to the Ethernet network with models that support: • Ethernet Modbus TCP/IP Protocol • EtherNet/IP Protocol • Direct mounting on equipment, eliminates need for enclosures • IP67 rated modules suited for harsh environments • Complete product offer with a full set of power, sensor, and Ethernet cables and accessories
Product overviewProduct features & specificationsSystem viewCompetitive positionCost comparisonsCustomer values
Product overview • 16 Point Digital Modules: available types • 16 digital Inputs • 12 Inputs/ 4 Outputs @ 2 Amps • 8 Inputs / 8 Outputs @ 2 Amps • 16 digital Inputs/Outputs configurable • Ethernet Protocols supported • EtherNet/IP • Modbus TCP/IP • Protection Level, IP67 Watertight • Extended Operating Temp. - 25°C to + 70°C • Built-in 2 port switch for Daisy Chain Connection • Integrated Web Server • Scrolling LED Display
Product overview Modbus TCP/IP ETB 1EM 16C POO 16 point module, configurable as inputs or outputs ETB 1EM 16E PPO 16 point input module ETB 1EM 12E 04S PPO 12 point input / 4 point output module ETB 1EM 08E 08S PPO 8 point input / 8 point output module EtherNet/IP ETB 1EI 16C POO 16 point module, configurable as inputs or outputs ETB 1EI 16E PPO 16 point input module ETB 1EI 12E 04S PPO 12 point input / 4 point output module ETB 1EI 08E 08S PPO 8 point input / 8 point output module
Product overview 2- Power connections, type 7/8 threaded connectors • Product Features 8 – Input/ Output point ports, 2 I/O points per connector, for M12 threaded and Ultra-Lock connectors Scrolling 4 digit LED Display 2 – Switched Ethernet communication ports, for M12 threaded and Ultra-Lock connectors
Product overview Power Cables Available in versions with connector at each end or with single connector at one end for connection to Power Supply. 4 Pin connector versions for EtherNet/IP 5 Pin connector versions for Modbus TCP • Complete Product Offer – Cables and Accessories Sensor Cables Available in versions with M12 threaded connectors or with quick release Ultra- Lock connectors. Also available are splitter cables to connect 2 sensors to a single I/O port. Ethernet Communication Cables Available in versions with an RJ 45 connector at one end and an M12 connector at other end, or versions with 2- M12 connectors. (Note: The cable jacket material is approved for both the European and North American markets)
Product overview Power Supply Cables to additional modules • Module with cables and accessories Power Tee Processor Splitter Cable to sensors Power Supply Ethernet Cable Adapter Ethernet Cable to connect next module Power Receptacle Enclosure
Target markets for IP67 I/O • Installed Base Customers - Automotive • Machining • Component Assembly • Body Assembly • Food and Beverage • Bottling • Packaging • Material Handling • Other • Mining, Minerals, & Metal – Material Handling • Printing • Pulp & Paper – Pulping Paper Machine Wet End
Target markets for IP67 I/O • Where to use Ethernet IP67 rated I/O Modules • Harsh Environments that include: • Oil and/or water spray • Extended operating temperature -25 to + 70°C • High vibration and shock • I/O Modules must or can be mounted directly on equipment • Field devices are located near I/O Modules, no long wire runs • There is no space available for I/O cabinets at location • Need to reduce the cost and time to install the I/O modules • Field devices selected are available with M12 connectors • Customers are using Ethernet as their industrial communication network
Product overviewProduct features & specificationsSystem viewCompetitive positionCost comparisonsCustomer values
Product features • Built for operation in harsh environments • IP67 Rated Module Package, Connectors, and Cables • Extended Operating Temperature Range -25°C to + 70°C • Flexible Mounting System • Benefit • Watertight, can be used in locations with oil and water spray • Used on plant floor or outdoors • Mounts directly on equipment – no need for enclosure
Product features • Reduced installed cost – Ethernet Switch • Built-in 2 Port Unmanaged Ethernet Switch with cross-over capability - allows daisy chain connections for Ethernet with no need for external switches • Daisy-chain connection for Power Supply Power Supply Daisy Chain connection – Up to 10 Modules Processor Ethernet
Product features • Reduced Installed Cost - M12- Ultra-Lock quick release Connector • Faster and easier to connect then standard threaded M12 • Easy to connect – even when difficult to access • Snap on for IP67 sealing of connections • Standard M12-connectors can also be used on modules
Product features • Reduced Installed Cost – Built-in Display with Control Buttons • 4-Character LED Display allows diagnosis without additional tools • Shows Current IP Address • Displays IP Address Configuration Mode • Control Buttons for Setting IP Address in Static Mode • Displays Errors • Network functions are displayed (e.g. ping)
Product features • Reduced Installed and Operating Cost – Integrated Web Server provides the following capabilities • Password Protection for Security • Module Configuration - IP Address, Module Parameters, and WDT Error behavior • Module Status Information • Remote Access and Diagnosis via Web – Interface • No additional software tool needed for configuration and diagnosis
Output Power Power present Power not connected Module & Input Power Power present Power not connected Input / Output Input / Output on Input / Output failed Input / Output off Displaywith information about Ethernet address, IO & watchdog status Product featuresModule diagnosis Ethernet Port 100MBit Communication 10MBit Communication
Module specifications • Common specifications for all modules Number of I/O Points16 Digital Points per Module I/O Configurations16 Inputs 12 Inputs / 4 Outputs 8 Inputs / 8 Outputs 16 I/O Points, User configurable I/O Points per Connectors 2 Points Power Requirements 24 VDC – Module and Input Power 13 to 28 VDC, 8 amp max. Outputs Input Type Compatible with Contact and 3 wire devices Input Delay 2.5 ms default, user configurable Output Current 2 amps per Output, 8 amps per Module Output Protection Electronic Short Circuit Protection Max. Switching Frequency 200 Hz Short Circuit Current 6.5 Amps (typical)
Module specifications • Common specifications for all modules(continued) Operating Temperature -25°C to + 70°C ( -4° to + 158°F) Storage Temperature -40°C to + 85°C ( -40° to + 185°F) Protection IP67 according to IEC 60529 Vibration IEC 60068-2-8 Mechanical Shock 10G, 11 ms, 3 axis MTBF 100,000 Hours Power Connectors 7/8 Connectors, 5 pin for Modbus TCP/IP 4 pin for EtherNet/IP Ethernet Connections M12 and Ultra-Lock Connectors, 4 pin I/O Connectors M12 and Ultra-Lock Connectors, 5 pin
Product overviewProduct features & specificationsSystem viewCompetitive positionCost comparisonsCustomer values
Typical system configuration • Ethernet (Modbus TCP/IP) based control system using a combination of IP67 and IP20 I/O PC/ Supervisory System Ethernet Switch/ M1 Processor Advantys ETB IP67 I/O mounted on equipment Advantys STB IP20 I/O mounted in cabinets
Typical system configuration • Control system topology for EtherNet/IP network PLC or IPC EtherNet/IP Switch Advantys ETB IP67 I/O mounted on equipment
Typical system configuration • Ethernet (Modbus TCP/IP) modules can be used with the following Schneider control systems: • Quantum system with NOE Ethernet interface • Premium system with ETY Ethernet interface • M340 system with NOE Ethernet interface • Momentum system using M1E Ethernet processors
Typical system configuration • EtherNet/IP modules can be used with the following Schneider control systems along with other control systems: • Quantum system with NOC Ethernet interface • Premium system with ETC Ethernet interface • Rockwell ControlLogix and CompactLogix systems = opportunity at competitive accounts
Typical I/O configuration • Advantys ETB I/O has the flexibility to be installed in the following configurations: • Daisy Chain • Star • Combination
Typical I/O configuration • Daisy Chain I/O configuration • Where to use Systems with I/O count under 160 I/O points Installations where I/O blocks are within 5 meters of the next block Applications where installed cost is an issue • Advantages Lower installed cost Eliminates external switch Easy to expand system Simplified troubleshooting and maintenance • Limitations Up to 10 modules per Daisy Chain Disconnecting 1 module will shut down the following modules in the daisy chain
Typical I/O configuration • Star configuration • Where to use Systems with large number of I/O points Installations where the I/O is not concentrated in one area Applications where system will be changing, with modules added, disconnected and reconnected to the network • Advantages Large number of modules per system (limitation is number of switches) Flexible module location • Disadvantages Higher installed cost, switches Longer cable runs, adds complexity Maintenance requires additional effort
Typical I/O configuration • Combination of Star and Daisy Chain configuration • Where to use Large systems with multiple machine or work areas • Advantages Segments modules into groups for each area Simplifies installation and troubleshooting Has lower installed cost than Star only network • Disadvantages Most effective for larger systems
Typical field devices • Advantys ETB I/O can connect directly to sensors and field devices that are available with M12 connectors and are IP67 rated. • Schneider Electric Sensors include: -Osiprox XS6 and XS8 Inductive Sensors -Osiris XUB Photoelectric Sensors -PhotoVirtu XUN Teachable Sensors -VM1 Ultra Sonic Sensors For the full range of Schneider Electric sensors, please visit our web site: http://www.sensors.com/
Product overviewProduct features & specificationsSystem viewCompetitive positionCost comparisonsCustomer values
Competitive advantages • Built-in Ethernet SwitchSave time and money by eliminating the need for external switches to connect modules • Integrated Web ServerSimplifies Module Configuration & Diagnostics No Additional Software Required • 4 Character DisplayReal Time Ethernet and Diagnostic Information • Quick Release ConnectorsFast connection to communications, and field devices
Product overviewProduct features & specificationsSystem viewCompetitive positionCost comparisonsCustomer values
IP67 I/O cost advantages • Lower installed cost • No need for cabinet or enclosure • Plug-in cables for Power, I/O, and Ethernet Communications • Simplified configuration via Web Pages or HMI Display Total Installed Cost€825.70 €655.00 Traditional I/O System Advantys ETB I/O I/O Modules Terminal Blocks Wiring Duct Field Sensors and Actuators
Installed cost comparison16 I/O points • Traditional I/O system (IP20) includes the following; • NEMA 4 metal enclosure 16”x12”x8” • 2 wires per device • Wiring from I/O module to Terminal blocks • Wiring from Terminal blocks to Field Devices • Power Wiring coming from outside 24 VDC Power Supply • Mounting I/O Module and Terminal Blocks • Labels for all wires • Advantys ETB IP67 Rated I/O modules includes the following • Power, Sensor, and Ethernet Cables • Labor to install 10 threaded type connectors into module • Not included in the installed cost comparison • I/O Modules, power supply, sensors or actuators • Labor to mount I/O module or enclosure on machine
26% lower installed cost for Advantys ETB I/O Installed cost comparisonAdvantys ETB IP67 vs IP20 • Summary of installed cost for 16 I/O points on Ethernet: Advantys ETB IP20 I/O Module cost (net)……..€216.00 €204.00 Installation cost……….€439.00€671.70 Total cost €655.00 €809.70 = €170.70 less
Product overviewProduct features & specificationsSystem viewCompetitive positionCost comparisonsCustomer values
Customer values • Simple Installation • I/O mounted directly on equipment eliminates the need for enclosures • Quick Release Connectors allow fast connection to power, communications, and field devices • Direct Connection to Ethernet Network without the need for external switches • Easy to Configure • Built-in Ethernet Switch for Network connections • Web Pages and Display simplifies integration and commissioning • Solution Approach • Can be combined with Schneider PLC’s, sensors, actuators, drives, and IP20 I/O for a total control system package • Complete solution with cables and accessories