1 / 41

Advantys ETB Ethernet IP67 I/O

Advantys ETB Ethernet IP67 I/O. Advantys ETB. Introducing Schneider Electric’s new family of IP67 rated I/O modules that connect to Ethernet. Advantys ETB Ethernet IP67 I/O modules. Direct connection to the Ethernet network with models that support: Ethernet Modbus TCP/IP Protocol

penda
Download Presentation

Advantys ETB Ethernet IP67 I/O

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Advantys ETB Ethernet IP67 I/O

  2. Advantys ETB Introducing Schneider Electric’s new family of IP67 rated I/O modules that connect to Ethernet.

  3. Advantys ETBEthernet IP67 I/O modules • Direct connection to the Ethernet network with models that support: • Ethernet Modbus TCP/IP Protocol • EtherNet/IP Protocol • Direct mounting on equipment, eliminates need for enclosures • IP67 rated modules suited for harsh environments • Complete product offer with a full set of power, sensor, and Ethernet cables and accessories

  4. Product overviewProduct features & specificationsSystem viewCompetitive positionCost comparisonsCustomer values

  5. Product overview • 16 Point Digital Modules: available types • 16 digital Inputs • 12 Inputs/ 4 Outputs @ 2 Amps • 8 Inputs / 8 Outputs @ 2 Amps • 16 digital Inputs/Outputs configurable • Ethernet Protocols supported • EtherNet/IP • Modbus TCP/IP • Protection Level, IP67 Watertight • Extended Operating Temp. - 25°C to + 70°C • Built-in 2 port switch for Daisy Chain Connection • Integrated Web Server • Scrolling LED Display

  6. Product overview Modbus TCP/IP ETB 1EM 16C POO 16 point module, configurable as inputs or outputs ETB 1EM 16E PPO 16 point input module ETB 1EM 12E 04S PPO 12 point input / 4 point output module ETB 1EM 08E 08S PPO 8 point input / 8 point output module EtherNet/IP ETB 1EI 16C POO 16 point module, configurable as inputs or outputs ETB 1EI 16E PPO 16 point input module ETB 1EI 12E 04S PPO 12 point input / 4 point output module ETB 1EI 08E 08S PPO 8 point input / 8 point output module

  7. Product overview 2- Power connections, type 7/8 threaded connectors • Product Features 8 – Input/ Output point ports, 2 I/O points per connector, for M12 threaded and Ultra-Lock connectors Scrolling 4 digit LED Display 2 – Switched Ethernet communication ports, for M12 threaded and Ultra-Lock connectors

  8. Product overview Power Cables Available in versions with connector at each end or with single connector at one end for connection to Power Supply. 4 Pin connector versions for EtherNet/IP 5 Pin connector versions for Modbus TCP • Complete Product Offer – Cables and Accessories Sensor Cables Available in versions with M12 threaded connectors or with quick release Ultra- Lock connectors. Also available are splitter cables to connect 2 sensors to a single I/O port. Ethernet Communication Cables Available in versions with an RJ 45 connector at one end and an M12 connector at other end, or versions with 2- M12 connectors. (Note: The cable jacket material is approved for both the European and North American markets)

  9. Product overview Power Supply Cables to additional modules • Module with cables and accessories Power Tee Processor Splitter Cable to sensors Power Supply Ethernet Cable Adapter Ethernet Cable to connect next module Power Receptacle Enclosure

  10. Target markets for IP67 I/O • Installed Base Customers - Automotive • Machining • Component Assembly • Body Assembly • Food and Beverage • Bottling • Packaging • Material Handling • Other • Mining, Minerals, & Metal – Material Handling • Printing • Pulp & Paper – Pulping Paper Machine Wet End

  11. Target markets for IP67 I/O • Where to use Ethernet IP67 rated I/O Modules • Harsh Environments that include: • Oil and/or water spray • Extended operating temperature -25 to + 70°C • High vibration and shock • I/O Modules must or can be mounted directly on equipment • Field devices are located near I/O Modules, no long wire runs • There is no space available for I/O cabinets at location • Need to reduce the cost and time to install the I/O modules • Field devices selected are available with M12 connectors • Customers are using Ethernet as their industrial communication network

  12. Product overviewProduct features & specificationsSystem viewCompetitive positionCost comparisonsCustomer values

  13. Product features • Built for operation in harsh environments • IP67 Rated Module Package, Connectors, and Cables • Extended Operating Temperature Range -25°C to + 70°C • Flexible Mounting System • Benefit • Watertight, can be used in locations with oil and water spray • Used on plant floor or outdoors • Mounts directly on equipment – no need for enclosure

  14. Product features • Reduced installed cost – Ethernet Switch • Built-in 2 Port Unmanaged Ethernet Switch with cross-over capability - allows daisy chain connections for Ethernet with no need for external switches • Daisy-chain connection for Power Supply Power Supply Daisy Chain connection – Up to 10 Modules Processor Ethernet

  15. Product features • Reduced Installed Cost - M12- Ultra-Lock quick release Connector • Faster and easier to connect then standard threaded M12 • Easy to connect – even when difficult to access • Snap on for IP67 sealing of connections • Standard M12-connectors can also be used on modules

  16. Product features • Reduced Installed Cost – Built-in Display with Control Buttons • 4-Character LED Display allows diagnosis without additional tools • Shows Current IP Address • Displays IP Address Configuration Mode • Control Buttons for Setting IP Address in Static Mode • Displays Errors • Network functions are displayed (e.g. ping)

  17. Product features • Reduced Installed and Operating Cost – Integrated Web Server provides the following capabilities • Password Protection for Security • Module Configuration - IP Address, Module Parameters, and WDT Error behavior • Module Status Information • Remote Access and Diagnosis via Web – Interface • No additional software tool needed for configuration and diagnosis

  18. Output Power Power present Power not connected Module & Input Power Power present Power not connected Input / Output Input / Output on Input / Output failed Input / Output off Displaywith information about Ethernet address, IO & watchdog status Product featuresModule diagnosis Ethernet Port 100MBit Communication 10MBit Communication

  19. Module specifications • Common specifications for all modules Number of I/O Points16 Digital Points per Module I/O Configurations16 Inputs 12 Inputs / 4 Outputs 8 Inputs / 8 Outputs 16 I/O Points, User configurable I/O Points per Connectors 2 Points Power Requirements 24 VDC – Module and Input Power 13 to 28 VDC, 8 amp max. Outputs Input Type Compatible with Contact and 3 wire devices Input Delay 2.5 ms default, user configurable Output Current 2 amps per Output, 8 amps per Module Output Protection Electronic Short Circuit Protection Max. Switching Frequency 200 Hz Short Circuit Current 6.5 Amps (typical)

  20. Module specifications • Common specifications for all modules(continued) Operating Temperature -25°C to + 70°C ( -4° to + 158°F) Storage Temperature -40°C to + 85°C ( -40° to + 185°F) Protection IP67 according to IEC 60529 Vibration IEC 60068-2-8 Mechanical Shock 10G, 11 ms, 3 axis MTBF 100,000 Hours Power Connectors 7/8 Connectors, 5 pin for Modbus TCP/IP 4 pin for EtherNet/IP Ethernet Connections M12 and Ultra-Lock Connectors, 4 pin I/O Connectors M12 and Ultra-Lock Connectors, 5 pin

  21. Product overviewProduct features & specificationsSystem viewCompetitive positionCost comparisonsCustomer values

  22. Typical system configuration • Ethernet (Modbus TCP/IP) based control system using a combination of IP67 and IP20 I/O PC/ Supervisory System Ethernet Switch/ M1 Processor Advantys ETB IP67 I/O mounted on equipment Advantys STB IP20 I/O mounted in cabinets

  23. Typical system configuration • Control system topology for EtherNet/IP network PLC or IPC EtherNet/IP Switch Advantys ETB IP67 I/O mounted on equipment

  24. Typical system configuration • Ethernet (Modbus TCP/IP) modules can be used with the following Schneider control systems: • Quantum system with NOE Ethernet interface • Premium system with ETY Ethernet interface • M340 system with NOE Ethernet interface • Momentum system using M1E Ethernet processors

  25. Typical system configuration • EtherNet/IP modules can be used with the following Schneider control systems along with other control systems: • Quantum system with NOC Ethernet interface • Premium system with ETC Ethernet interface • Rockwell ControlLogix and CompactLogix systems = opportunity at competitive accounts

  26. Typical I/O configuration • Advantys ETB I/O has the flexibility to be installed in the following configurations: • Daisy Chain • Star • Combination

  27. Typical I/O configuration • Daisy Chain I/O configuration • Where to use Systems with I/O count under 160 I/O points Installations where I/O blocks are within 5 meters of the next block Applications where installed cost is an issue • Advantages Lower installed cost Eliminates external switch Easy to expand system Simplified troubleshooting and maintenance • Limitations Up to 10 modules per Daisy Chain Disconnecting 1 module will shut down the following modules in the daisy chain

  28. Typical I/O configuration • Star configuration • Where to use Systems with large number of I/O points Installations where the I/O is not concentrated in one area Applications where system will be changing, with modules added, disconnected and reconnected to the network • Advantages Large number of modules per system (limitation is number of switches) Flexible module location • Disadvantages Higher installed cost, switches Longer cable runs, adds complexity Maintenance requires additional effort

  29. Typical I/O configuration • Combination of Star and Daisy Chain configuration • Where to use Large systems with multiple machine or work areas • Advantages Segments modules into groups for each area Simplifies installation and troubleshooting Has lower installed cost than Star only network • Disadvantages Most effective for larger systems

  30. Typical field devices • Advantys ETB I/O can connect directly to sensors and field devices that are available with M12 connectors and are IP67 rated. • Schneider Electric Sensors include: -Osiprox XS6 and XS8 Inductive Sensors -Osiris XUB Photoelectric Sensors -PhotoVirtu XUN Teachable Sensors -VM1 Ultra Sonic Sensors For the full range of Schneider Electric sensors, please visit our web site: http://www.sensors.com/

  31. Product overviewProduct features & specificationsSystem viewCompetitive positionCost comparisonsCustomer values

  32. Competitive advantages • Built-in Ethernet SwitchSave time and money by eliminating the need for external switches to connect modules • Integrated Web ServerSimplifies Module Configuration & Diagnostics No Additional Software Required • 4 Character DisplayReal Time Ethernet and Diagnostic Information • Quick Release ConnectorsFast connection to communications, and field devices

  33. Competition

  34. Product overviewProduct features & specificationsSystem viewCompetitive positionCost comparisonsCustomer values

  35. IP67 I/O cost advantages • Lower installed cost • No need for cabinet or enclosure • Plug-in cables for Power, I/O, and Ethernet Communications • Simplified configuration via Web Pages or HMI Display Total Installed Cost€825.70 €655.00 Traditional I/O System Advantys ETB I/O I/O Modules Terminal Blocks Wiring Duct Field Sensors and Actuators

  36. Installed cost comparison16 I/O points • Traditional I/O system (IP20) includes the following; • NEMA 4 metal enclosure 16”x12”x8” • 2 wires per device • Wiring from I/O module to Terminal blocks • Wiring from Terminal blocks to Field Devices • Power Wiring coming from outside 24 VDC Power Supply • Mounting I/O Module and Terminal Blocks • Labels for all wires • Advantys ETB IP67 Rated I/O modules includes the following • Power, Sensor, and Ethernet Cables • Labor to install 10 threaded type connectors into module • Not included in the installed cost comparison • I/O Modules, power supply, sensors or actuators • Labor to mount I/O module or enclosure on machine

  37. 26% lower installed cost for Advantys ETB I/O Installed cost comparisonAdvantys ETB IP67 vs IP20 • Summary of installed cost for 16 I/O points on Ethernet: Advantys ETB IP20 I/O Module cost (net)……..€216.00 €204.00 Installation cost……….€439.00€671.70 Total cost €655.00 €809.70 = €170.70 less

  38. Installed cost comparison16 I/O points

  39. Product overviewProduct features & specificationsSystem viewCompetitive positionCost comparisonsCustomer values

  40. Customer values • Simple Installation • I/O mounted directly on equipment eliminates the need for enclosures • Quick Release Connectors allow fast connection to power, communications, and field devices • Direct Connection to Ethernet Network without the need for external switches • Easy to Configure • Built-in Ethernet Switch for Network connections • Web Pages and Display simplifies integration and commissioning • Solution Approach • Can be combined with Schneider PLC’s, sensors, actuators, drives, and IP20 I/O for a total control system package • Complete solution with cables and accessories

More Related