1 / 45

Calcium Imaging and Voltage-sensitive dyes

Calcium Imaging and Voltage-sensitive dyes. Membrane Biophysics 10/26/2007. - Joseph M. Breza -. Outline. 1) Backgroud Calcium-sensitive dyes, Calcium imaging.

pepper
Download Presentation

Calcium Imaging and Voltage-sensitive dyes

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Calcium Imaging and Voltage-sensitive dyes Membrane Biophysics 10/26/2007 - Joseph M. Breza -

  2. Outline 1) Backgroud Calcium-sensitive dyes, Calcium imaging 2) Riera CE, Vogel H, Simon SA, le Coutre J. Artificial sweeteners and salts producing a metallic taste sensation activate TRPV1 receptors, Am J Physiol Regulatory Integrative Comp Physiol 293:626-634, 2007. 3) Background Voltage-sensitive dyes, imaging

  3. Calcium The ion of the nervous system Neurotransmitter release into synapse via vesicle release proteins Signaling cascades Cell division Blood clotting Fertilization Amount of Calcium needed for effect is relatively small

  4. Fluorescence: Is the phenomenon in which the molecular absorption of a photon triggers the emission of another photon with a longer wavelength. (named after calcium fluoride “Fluorite”) * Stimulate in the ultraviolet range, and the emitted light is in the visible range.*

  5. Agar Plate of Fluorescent Bacteria Colonies QUIN 2 was a member of the first generation of Ca2+ chelators introduced by Tsien in 1980

  6. Calcium Imaging Fluorescence detection system 1) Fluorophore- fluorescent molecule (photo bleaching) 2) Wavelength filters 3) Excitation source (light source UV) 4) Detector Fluorescence instruments 1) Spectrofluorometer – analyzes fluorescence (before – after) 2) Flow cytometer- analyzes, sorts, counts microscopic particles in stream of fluid-doesn’t produce and image of the cell 3) Fluorescence microscope - filters weak fluorescent light from other lights

  7. Calcium sensitive dyes are Chelators Many different types of calcium fluorescent dyes Type used depends on the cell type - experience Research goal (salt/lipophilic forms, low/intermediate/high affinity, fast calcium spikes, fluorescence, method of delivery, etc) Low-affinity calcium indicators Fura-FF BTC Fura-2 Fura-5, Indo-1) Excited by UV light Intermediate-affinity calcium Fura-4F Fura-5F Fura-6F Excited by UV light Excited by visible light under scanning laser confocal microscopy High-affinity and selectivity (BAPTA) Calcium Green, Calcium Orange – Tomchik et al 2007

  8. Fluorescent microscope Protects eyes from UV light

  9. Figure 2 PLCβ2 negative G-proteins CaGD- Calcium Fluorescence

  10. Figure 4 PLCβ2-GFP Mouse (Receptor cell) GAD-GFP Mouse (Presynaptic cell)

  11. Artificial sweeteners and salts producing a metallic taste sensation activate TRPV1 receptors Am J Physiol Regulatory Integrative Comp Physiol 293:626-634, 2007. Authors: Riera CE, Vogel H, Simon SA, le Coutre J.

  12. Figure 1.

  13. Figure 2.

  14. Figure 3.

  15. Figure 4

  16. Figure 5

  17. Figure 6

  18. Voltage sensitive dyes

  19. Voltage-sensitive dyes A plethora of them to choose from…depends on tissue (experience) Vary considerably in active duration, loading, etc. “Sticks” to the plasma membrane Changes in membrane potential are recorded with a photo diode (464 pixels 1010 photons per frame) ~1nA photocurrent and dye sensitivity of ~1%/100mV Can calculate membrane potential within 3 mV Change in Fluorescence can be between ~1-21% / 100mV change (RH421).

  20. Measure Active Conductances – Voltage gated Na, K, Ca2+ Channels What’s the advantage?

  21. Photodiode

  22. Optical recording of synaptic release Digital Camera Pseudocolor output of camera Transgenic olfactory bulb

  23. The pH-sensitive protein: synaptopHluorin Mutagenized Green Fluorescence Protein Neuron. 2005 Dec 22;48(6):1039-53. can accept a proton to change fluorescence fused to VAMP2 expressed in mice targets to synaptic vessicles in vivo When synaptic vessicle fuses with membrane pH increase almost instantly fluorescence increases almost instantly

  24. pH of: vesicle extracellular Gero Miesenböck, Dino A. De Angelis and James E. Rothman Nature 394, 192-195(9 July 1998)

  25. Odorant Representations Are Modulated by Intra- but Not Interglomerular Presynaptic Inhibition of Olfactory Sensory Neurons McGann JP, Pírez N, Gainey MA, Muratore C, Elias AS, Wachowiak M. Question: How does presynaptic inhibition really work in the olfactory bulb glomerulus?

  26. Single glomerulus: 2 bundles of OSNs Single bundle are cumulative Paired-pulse results in depression Depression alleviated by: GLU blockers GABA blockers

  27. Optical recording of voltage changes in vivo photodiode array Pseudocolor output of the array turtle http://www.redshirtimaging.com

  28. Voltage-sensitive dyes A plethora of them to choose from…depends on tissue (experience) Vary considerably in active duration, loading, etc. “Sticks” to the plasma membrane Changes in membrane potential are recorded with a photo diode (464 pixels 1010 photons per frame) ~1nA photocurrent and dye sensitivity of ~1%/100mV can calculate membrane Potential within 3 mV Change in Fluorescence can be between ~1-21% / 100mV change (RH421).

  29. Binaral interaction and centrifugal input enhances spatial contrast in olfactory bulb activation. Singer, Benjamin H., Kim, Soyoun & Zochowski, Michal European Journal of Neuroscience 25 (2), 576-586. Question: What role do centrifugal inputs play in OB activation?

  30. Schematic of olfactory bulb neurotransmitters and cellular connections Note: All of these different neurotransmitters are coming from BOTH sides of brain Doty RL (1995), Handbook of Olfaction and Gustation, Marcel Dekker.

  31. Experimental design and controls Replicates with one odorant

  32. Paired-pulse with different odorants results in increased inhibition This would have been difficult to see with standard electrophysiology or behavior

  33. Caged- Compoundsor the light shall set you free

  34. Flash-activation of compounds won the 1967 prize in Noble Prize in Chemistry Light-induced isomerization acetylcholine agonists by Wasserman and Erlanger 1971 only trans isomer biologically active (Bis-Q) Many kinds today used on: Ca++ cNMP glutamate GABA peptides

  35. Photolysis of Caged Glutamate UV photon Caging compound Glutamate Requirements of caging compounds/ systems: Masks the biomolecule completely Releases the biomolecule completely No deleterious by-products No biomolecule breakdown http://flavor.monell.org/%7Eloweg/Techniques.htm

  36. Photolysis and Recording Set-up Beam can be moved in X-Y plane and in Z-plane for discrete anatomical placement Or discrete channels can be placed with the compound http://flavor.monell.org/%7Eloweg/Techniques.htm

  37. Discrete Release of Caged Compound Lowe, G. J Neurophysiol 88: 64-85 2002

  38. Flash photolysis reveals a diversity of ionotropic glutamate receptors on the mitral cell somatodendritic membrane. Lowe G. J Neurophysiol. 2003 90(3):1737-46. Question: Are glutamate rececptors located on the mitral cell soma/ proximal dendrites?

  39. Glutamate elicts fast and slow currents Photolysis at arrow on soma/ proximal dendrite NBQX= AMPA antagonist APV= NMDA antagonist (comp) dCK= NMDA glycine site antagonist (comp) Mg++ -free bath Lowe, G. J Neurophysiol 90: 1737-1746 2003; doi:10.1152/jn.00180.2003

  40. Competitive inhibition of NMDA current Lowe, G. J Neurophysiol 90: 1737-1746 2003; doi:10.1152/jn.00180.2003

  41. Fast Glutamate Current = AMPA? All slow glutamate currents blocked Fast current remains CTZ= AMPA postitve allosteric modulator Lowe, G. J Neurophysiol 90: 1737-1746 2003; doi:10.1152/jn.00180.2003

  42. Fast Glutamate Current = a little Kainate? All slow glutamate currents blocked Fast current remains SYM2206= Kainate blocker

More Related