1 / 6

Anaesthesia-System-MD-ANS-1002

Medical Deals Anaesthesia System features a 10.4" colour TFT LCD, adjustable ventilation rates, and alarms for AC power failure and low voltage. Powered by Ou2082, Nu2082O, and AIR with a flowmeter range of 0.1u201310 L/min, it ensures reliability with an internal battery backup.

peters385
Download Presentation

Anaesthesia-System-MD-ANS-1002

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Anaesthesia System MD-ANS-1002

  2. Anaesthesia System MD-ANS-1002 Anesthesia system MD-ANS-1002 offers an Inspiratory to Expiratory Ratio Configurable from 2:1 to 1:6. It provides the ability to fine-tune the breathing cycle. It also provides precise gas flow control for O2, N2O, and AIR, ranging from 0.1 to 10 L/min each. The system is designed for ease of operation with intuitive controls and a digital display. That provides real-time monitoring and alarm notifications. Our Anesthesia system is ideal for modern operating rooms, offering advanced control, flexibility, and safety features that cater to the diverse needs of patients. Features: 10.4"Colorful TFT LCD Adjustable ventilation rates Rapid Oxygen Supply SIGH: prevent atelectasis Oscillogram Display AC Power Failure Alarm Internal Battery Backup Low Voltage Alarm Vaporizer Safety Suffocation Warning Power Failure or No Connection Alert Standard accessories: Anesthetic breathing system × 1 Power cord 4m × 1 Fuse × 2

  3. Fuse × 1 O2 cell × 1 Breathing tube × 2 Breathing tube × 1 Breathing tube × 2 Y connector Adult × 1 Y connector Child × 1 L connector × 2 Straight connector (?22 to ?22) × 1 Reservoir bag 1L × 1 Reservoir bag 3L × 1 Anesthetic mask adult × 1 Anesthetic mask infant × 1 Anesthesia Vaporizer × 1 High pressure O2 hose × 1 High-pressure AIR hose × 1 High pressure N2O hose × 1 Optional accessories: CO2 sensor × 1 Transfer and receiving system of exhaust gas × 1 Patient monitor × 1

  4. Applications: Anesthesia System MD-ANS-1002 offers high performance in ICUs, operating rooms, and anesthesiology ensuring maximum patient safety and ease of use across adult, child, and infant anesthesia and respiratory care.

  5. Specifications : Ventilation Modes IPPV, A/C, SIMV, SIGH, MANUAL Gas Source O2, N2O, AIR O2: 0.1 to 10 L/min; N2O: 0.1 to 10 L/min AIR: 0.1 to 10 L/min Flowmeter range Rapid Oxygen Supply Range 25 L/min to 75 L/min Oxygen Concentration 15 % to 100 % Tidal Volume (Vt) range 0, 20 mL to 1500 mL Minute Volume (MV) 0 L/min to 100 L/min Maximum Minute Volume ?18 L/min Frequency range 1 /min to 100 /min Inspiratory Ratio (I) 2:1 - 1:6 Positive End-Expiratory Pressure (PEEP) 0 cmH2O to 30 cmH2O Pressure Triggering Sensitivity (PTr) -20 cmH2O to 20 cmH2O Flow Trigger Sensitivity (FTr) 0.5 L/min to 30 L/min SIGH 0 (off) 1/100 to 5/100 Apnea Ventilation OFF, 5 s to 60 s Gas Pressure Range 280 kPa to 600 kPa Pressure Limit 20 cmH2O to 100 cmH2O Bellow 1.5L P-T (Pressure-Time), F-T (Flow-Time), P-V loop (Pressure-Volume Loop) Oscillogram Types AC Power Failure Alarm Yes Battery Backup Low Voltage Alarm Yes; threshold 11.3 ± 0.3 V Tidal Volume Alarm Triggered if no tidal volume is detected 19 % to 100 % (High); 18 % to 99 % (Low) High/Low Oxygen Concentration Alarm High: 20 cmH2O to 100 cmH2O; Low: 0 cmH2O to 20 cmH2O Airway Pressure Alarms Adult: 5 L/min to 20 L/min; Pediatric: 1 L/min to 15 L/min Minute Volume Alarms Continuous Pressure Alarm Over (PEEP + 1.5 kPa) for 16 s

  6. Suffocation Warning 5 s to 60 s with no spontaneous ventilation Maximum Limited Pressure ?12.5 kPa Fan Error, Oxygen Deficit, Power Failure Displayed on screen Display 10.4"Colorful TFT LCD Power Consumption 80VA Voltage: 100 to 240 V Power Frequency: 50/60 Hz Power Supply Packing Dimension 920 × 970 × 1390 mm Net Weight 87.5 kg Gross Weight 155 kg 22 Bull Street, Savannah, GA 31401, USA Email: info@medicaldeals.com | Website: Medical Deals Ltd. | Phone: +1 506 699 0674