Diagnosing cardiac disease states using a minimal cardiovascular model Christina Starfinger Wednesday, 21 March 2007 HRSC Scientific Meeting. Current Clinical Process. Measure limited clinical data
E N D
Diagnosing cardiac disease states using a minimal cardiovascular model Christina Starfinger Wednesday, 21 March 2007 HRSC Scientific Meeting
Current Clinical Process • Measurelimited clinical data • Diagnosebased on data trends observed and approximate mental models of physiological function and pathology – typically based on an “average patient” • Treatby selecting a therapy based on standard protocols or methods for diagnosed disease state Problems: • No means of aggregating often conflicting data into a clear picture • Many disease states show very similar measurements clinically confusing the diagnostic picture • Reflex actions can mask disease states until they are acute • Limited measurements are typically used (“task overload”)
Model-Based Solution • Identifypatient specific parameters from measured clinical data to create patient specific CVS model • Diagnosedisease state from patient-specific parameter values • Treatusing patient-specific model to predict results of different therapeutic strategies/interventions (Therapy Decision Support) Outcomes: • Real-time, patient specific CVS model • Assistance in diagnoses and therapy selection • Uses data and catheters typically found in the ICU
Model Left ventricle (LV) Right ventricle (RV) Vena Cava, Aorta, Pulmonary artery/vein Pulmonary circulation Systemic circulation
Model Right ventricle Left ventricle Pulmonary Artery Vena Cava Pulmonary Vein Aorta Smith, BW, Chase, JG, Shaw, GM and Nokes, RI (2006). “Simulating Transient Ventricular Interaction Using a Minimal Cardiovascular System Model,” Physiological Measurement, IOP, Vol 27, pp. 165-179
Identification Problem Measurements Required: • Max/Min Pressure in aorta (SAP, DAP) • Max/Min Pressure in pulmonary artery (SPAP, DPAP) • Max/Min Volume in left ventricle (LVEDV,LVESV) • Max/Min Volume in right ventricle (RVEDV,RVESV) • Heart Rate Model Parameters Identified:Integral-based methods Lav,Lmt,Ltc,Lpv,Eeslvf,Eesrvf,Polvf,Porvf,Rav,Rmt,Rtc,Rpv, Eao,Epa,Evc,Epu,Rsys, Rpul Measurements required are a minimal set compared to the total number of parameters identified in the model Given or estimated Find Hann, CE, Chase, JG and Shaw, GM (2006). “Integral-based Identification of Patient Specific Parameters for a Minimal Cardiac Model,” Computer Methods and Programs in Biomedicine, Vol 81(2), pp. 181-192
Diagnosis from ID Contractilities, increased during increased sympathetic activity (HR ↑) Parameters: Lav,Lmt,Ltc,Lpv,Eeslvf,Eesrvf,Polvf,Porvf,Rav,Rmt,Rtc,Rpv, Eao,Epa,Evc,Epu,Rsys, Rpul Resistances for 4 heart valves, increased for stenosis Pulmonary vascular resistance and systemic vascular resistance, increased for example in PE, and PHT
Pulmonary Embolism Experiment: • 6 pigs, 32.75kg ± 1.83kg • pulmonary embolization induced with autologous blood clots • clots were injected every two hours with decreasing concentrations Measurements: • aortic pressure (Pao) and pulmonary artery pressure (Ppa) are measured using micromanometer-tipped catheters (Sentron pressure-measuring catheter;Cordis, Miami, FL) • right and left ventricle pressures and volumes (Vlv,Vrv,Plv,Prv) are measured using 7F, 12 electrodes (8-mm interelectrode distance) conductance micromanometer tipped catheters (CD Leycom, Zoetermeer, The Netherlands) Goal: • Accurate identification at all stages of induced embolism with no false parameter value changes Data from Ghuysen et al, Hemodynamics Laboratory, Univ of Liege
Results for PE (ID) - 1 Left ventricle (30 mins) Right ventricle (30 mins) Errors ~5% and all peak and stroke values captured
Results for PE (ID) - 2 Pulmonary resistance (Pig 2) Rpul – All pigs Right ventricle expansion index (RVEDV/LVEDV, Pig 2) Reflex actions (Pig 2)
PEEP Titrations Experiment: • 6 pigs (2 used so far for analysis: 21kg) • 5 PEEP titrations at different blood volumes: • Baseline • Removal of blood (Hypovolemia) • Reinfusion of blood • Infusion of saline • Infusion of more saline • Each PEEP titration included PEEP levels of 0,10 and 20 cmH20 Measurements: • Measurements recorded using PiCCO, Servo-i, Vigilance and SC9000 monitors • Vlv, Vrv were estimated based on TBV and GEDV Goal: • Predict the effect of PEEP therapy on SV (etc) in presence of different blood volumes Data from Smith et al MMDS, Aalborg University
Results for PEEP-Prediction • Goals: • Match peak pressures • Match stroke volumes • Volumes close • Pressures accurate
Results for PEEP-Prediction Errors ~10% + Trends Captured!
Conclusions • Model-based Identification, Diagnosis and Therapy Decision Support methods presented • Validated on two clinical data sets using porcine animal models • Pulmonary embolism • PEEP intervention at different blood volumes • Results show good accuracy (<10% error) for critical parameters • No false parameter value changes in identification implies a model of the proper level of complexity for these disease states • Future Work = Septic Shock (April 2007) and further disease states
Acknowledgement • Questions ? ? ? Engineers and Docs Dr Chris Hann Dr Geoff Chase Dr Geoff Shaw Denmark (PEEP Data) Belgium (PE Data) Dr Bram Smith Prof Steen Andreassen Dr Thomas Desaive Dr Bram Smith