1 / 33

PETE 411 Well Drilling

PETE 411 Well Drilling. Lesson 25 Well Control, cont’d. Well Control, cont’d. Shut-in Procedures after Taking a Kick Kick Occurs While Drilling Kick Occurs While Tripping Casing Pressures During Well Control Operations Kick on Bottom Kick at surface

pilar
Download Presentation

PETE 411 Well Drilling

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PETE 411Well Drilling Lesson 25Well Control, cont’d

  2. Well Control, cont’d Shut-in Procedures after Taking a Kick Kick Occurs While Drilling Kick Occurs While Tripping Casing Pressures During Well Control Operations Kick on Bottom Kick at surface Kick Migration During Shut-in Conditions Kicks on Trips/ Wellbore Fillup

  3. Read:Applied Drilling Engineering, Ch.4 HW #14Well Control – Driller’sdue November 11, 2002

  4. Controlling A Kick when On Bottom Procedure: 1. Raise the kelly to clear the tool joint above the rotary 2. Shut down the pump 3. Check for well flow

  5. Controlling A Kick when On Bottom 4. If well is flowing, immediately close the blowout preventer and shut in the well completely, (except on shallow gas kicks). 5. Notify supervisory personnel. 6. Read and record the stabilized shut-in drill-pipe pressure. (SIDPP)

  6. Controlling A Kick When On Bottom 7. Read and record the stabilized shut-in casing pressure (SICP) 8. Read and record the pit gain (pit-level increase = kick size) 9. Record the time 10. Record depth 11. Record mud weight

  7. Controlling A Well Kick While Making A Trip 1. Stop trip operations. Set slipswith tool joint at rotary. 2. Install inside blowout preventer and release valve stem or close the valve if drill-stem valve is employed.

  8. Controlling A Well Kick While Making A Trip 3. Immediately close the blowout preventer and shut in the well completely (except on shallow gas kicks). 4. Install kelly, open drill-pipe valve, or pump through back-pressure valve.

  9. Controlling a Well Kick While Making A Trip 5. Notify supervisory personnel 6. Read and record the stabilized shut-in drill- pipe pressure or equivalent (SIDPP) 7. Read and record the stabilized shut-in casing pressure(SICP)

  10. Controlling A Well Kick While Making A Trip 8. Read and record the pit gain (Kick Size) 9. Record the time 10. Record the current welldepth 11. Record the current mud weight

  11. 200 psi 400 psi Variable Geometry Kick On Bottom - Well Shut In 4,000’ 9,500’ 10,000’ hB = 445’ PB = 5,700 psi

  12. Variable Geometry 1. Calculate new BHP: 2. Calculate height of kick (check geometry). 3. Calculate density of kill mud:

  13. Variable Geometry 4. Calculate the density of kick fluid: How would you derive this equation?

  14. ho Engineer’s Method - Gas Kick at surface D* Gas Bubble 10.0 lb/gal 10.38 lb/gal PB = const = 0.052 * r kill * depth

  15. 1. Calculate expansion of gas bubble 2. BHP = Press at top of kick + DP HYD,Annulus 3. Solve the resulting quadratic equation to get the pressure

  16. BHP = PTOP + S (gi * hi ) gi = 0.052 * ri )

  17. Well is Shut In Gas Bubble Will Rise ! Bubble Rise Velocity ?

  18. 1,998 psi 50 bbl kick 1,266 psi CASING PRESSURE, psi 20 bbl kick 989 psi 10 bbl kick BARRELS OF KILL MUD PUMPED

  19. Well Control Avoid kicks if possible Catch them early if they do occur Know how to control kicks if they do occur

  20. Avoiding Kicks While Tripping: Keep the hole full. Avoid excessive surge pressures. Avoid excessive swab pressures

  21. Tripping Out of Hole A good drilling engineer will always stay on the rig floor during the first 20 stands of a trip. 1. Make sure pipe is not pulled too fast. 2. Make sure annulus is kept full. e.g. fill every 5 stands, and measure volume required to fill hole.

  22. Tripping Out Of Hole If well is not taking enough fluid to replace volume of steel pulled from hole, fluid may have been swabbed into well. Measurefluid volume to fill hole: 1. By counting pump strokes, or 2. By direct measurement from trip tank. Note: The second method is best.

  23. Annular Fill-Up On Trips Example 1 How much fill-up is required after pulling 5 stands of 5” OD, 19.5 #/ft drillpipe with extrahole tool joints? [ Each stand is 93 ft long ].

  24. Annular Fill-Up On Trips (i) Mud drains out through nozzles ………bbls (steel only) (ii) Nozzles are plugged ……… bbls (steel + mud)

  25. Example (i)Vol. of steel only: (nozzles not plugged) From Table 1.6, actual weight in air is 20.60 lb/ft.

  26. Example

  27. Example Check: From Table 1.6,

  28. Example (ii) Nozzles are plugged: From Halliburton book, internal capacity of 19.50 #/ft, 5” O.D. drillpipe is 0.01776 bbl/ft.

  29. Example Volume of fill-up req’d = 3.48 + 8.26 = 11.74 bbls How much did the fluid level drop? How much did the BHP drop?

  30. Recommendations Fill hole after each 5 stands of drill pipe when coming out of hole. Fill hole after each stand of drill collars when coming out of hole. When GIH after an extended period of time, break circulation gradually, at several different depths...

  31. Recommendations Do not break circulation with bit and BHA just above the casing seat. When breaking circulation, Start the pumps slowly, Rotate the drill string, Pick up on the drillstring at the same time This will reduce the initial pressure required to get the mud moving