1 / 13

WinIso 2D

WinIso 2D The software solution calculates heat flows in any two -dimensional cross sections . These are the basics to determine the heating demands and loss and the prevention of moisture in building components and its surface. WinIso 2D the programm calculates :

polly
Download Presentation

WinIso 2D

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. WinIso 2D • The softwaresolutioncalculatesheatflows in anytwo-dimensional crosssections. • These arethebasicstodeterminetheheatingdemandsandlossandthepreventionofmoisture in buildingcomponentsanditssurface.

  2. WinIso 2D • theprogrammcalculates: • temperature, isothermallines, heatflows • heattransfercoefficientofsinglecomponentsandofthe hole buildingcomponent • surfacetemperature • thermal bridgesvalueΨ • condensatewater in thebuildingcomponents • temperaturfactorfRsi

  3. CAD - Import • youcanimport CAD-drawingswiththe DXF-Converter • oryoucandrawcrosssections in theprogram

  4. material • theprojectisdefinedbyfillingthecellswithproject material • material with thermal and hygrothermal characteristicsaresaved in the material database • youcanaddorchangematerials

  5. illustration • youcandefineoracceptclimateconditions • showsthetemperaturedistribution • showstheheatflows

  6. illustration • isothermallinessimplifytheinterpretation

  7. fRsiandsurfacetemperature • youcangetthesufacetemperature • andthefRsibyone • click

  8. condensatewater • to check thecondensatewater in thebuildingcomponentsor on thesurface press

  9. U - value • itispossibletoshow u-valueandtemperaturedistributionateverypointofthecrosssection

  10. Uf- und Ψ - value • Uf-valueandPsi-valuearecalculatedaccordingto EN10077

  11. Uw - value • theUw-valuecanbecalculatedwithUg, Uf, ΨandthemeasurementsoftheWindow

  12. printout • crosssection in anyillustration • completedocumentationof all values, materials, temperaturesand U-values • personal title block canbeinserted

  13. forfurtherinformation • www.winiso2d.de • Sommer Informatik GmbH • Sepp-Heindl-Str. 5 • D-83026 Rosenheim • Tel.: +49 (0)8031 2488-1 • Fax: +49 (0)8031 2488-2

More Related