1 / 7

n-EDM Collaboration Meeting: Precision Magnetometry Alex Sushkov and Dima Budker Berkeley

n-EDM Collaboration Meeting: Precision Magnetometry Alex Sushkov and Dima Budker Berkeley. UIUC, December 2-3, 2004. Linear Polarization. Medium. . Circular Components. Magnetic Field. The Concept. Commercial dense flint glasses: V~3  10 -5 rad/G/cm

portia
Download Presentation

n-EDM Collaboration Meeting: Precision Magnetometry Alex Sushkov and Dima Budker Berkeley

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. n-EDM Collaboration Meeting:Precision MagnetometryAlex Sushkov and Dima Budker Berkeley UIUC, December 2-3, 2004

  2. Linear Polarization Medium  Circular Components Magnetic Field The Concept • Commercial dense flint glasses: V~310-5 rad/G/cm • Atomic vapor (very-high vacuum): V~104 rad/G/cm • ~1020 greater rotation "per atom"

  3. Cold Atomic Magnetometer • Expected B-field from 3He spins: B ~ 2×1012 • 10-20/2000 • 2.1 • 8 ~ 2×10-10 G • State-of-the-art SQUIDs ~ 3×10-11 G/Hz1/2at 4 K • Demonstrated warm atomic magnetometers ~ 10-11 G/Hz1/2 • The goal for the cold Ag magnetometer: B-field sensitivity ~ 10-12 G/Hz1/2 or better and operation around 4 K • This corresponds to spin-relaxation time of ~ 30 seconds • Spin-relaxation times around 60 seconds have been indirectly observed [Yabuzaki]

  4. Cold Atomic Magnetometer

  5. Cold Atomic Magnetometer

  6. Cold Atomic Magnetometer

  7. Quantum Non-Demolition and Spin-Squeezing • How do the noise properties of an atomic magnetometer or an EDM experiment scale with the number N of the species under study? • 1/√N? • Fundamental noise sources for an atomic magnetometer: • quantum projection noise • photon shot-noise • For short measurement times (τ « τrel/√N), the optimal sensitivity scales as N-3/4 • But at longer measurement times (τ ~ τrel) the optimal sensitivity scales as 1/√N, as for a usual shot-noise limited system • If strongly squeezed probe light is used, the Heisenberg limit may, in principle, be reached for very short measurement times, but once again the 1/√N scaling is restored for τ ~ τrelM. Auzinsh, D. Budker D. F. Kimball, S. M. Rochester, J. E. Stalnaker, A. O. Sushkov, and V. V. Yashchuk, Phys. Rev. Lett.93(17), 173002 (2004); physics/0403097 .

More Related