1 / 17

Semester 4 – Chapter 6 - Frame Relay

Semester 4 – Chapter 6 - Frame Relay. Frame Relay - Industry-standard, switched data-link layer protocol that handles multiple virtual circuits using HDLC encapsulation between connected devices.

quilla
Download Presentation

Semester 4 – Chapter 6 - Frame Relay

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Semester 4 – Chapter 6 - Frame Relay • Frame Relay - Industry-standard, switched data-link layer protocol that handles multiplevirtual circuits using HDLC encapsulation between connected devices. • Frame Relay is more efficient than X.25, the protocol for which it is generally considered a replacement. • By using a simplified framing with no error correction mechanisms over high-quality digital facilities, Frame Relay can transmit data very rapidly, compared to other WAN protocols. • Frame Relay uses Layer 2 identifiers (DLCIs) and Permanent Virtual Circuits (PVCs).

  2. Frame-Relay Technologies Frame Relay WAN technology provides a flexible method of connecting LANs over Frame Relay WAN links: • A ITU-T (CCITT) & American National Standards Institute (ANSI) standard • Defines the process for sending data over a Public Data Network (PDN) • Uses Virtual Circuits (VCs) to establish connections across the WAN • A connection-oriented service - the complete path to the destination is established prior to the sending of the first frame

  3. Technologies Continued • DLCIs are used to identifyVirtualCircuits • Provides a means for multiplexing many logical data conversations (referred to as virtual circuits) by assigning each pair of DTEs connectionidentifiers • Can divide a single Physical WAN Interface into multipleSubinterfaces • Operates at the Physical and DataLink Layers of the OSI model but it relies on upper-layerprotocols such as TCP for errorcorrection • A data-link technology that is streamlined (littleerrorchecking) to provide high performance and efficiency • Defines the interconnection process between the Customer Premises Equipment (CPE) (also known as data terminal equipment - DTE), such as a router, and the service provider's local access switching equipment (known as data communications equipment - DCE)

  4. Packet/Cell Switched Connections Frame Relay (key points): • Simpler and faster than X.25 • PVC (Permanent Virtual Circuit) only, SVC (Switched Virtual Circuit) has been specified • Access is at 56 kbps, 64 kbps, or 1.544 Mbps • Typically operates up to T1 • Very streamlined (littleerrorchecking) • Has none of the reliability features/complexity of X.25 • Uses: • LAN-to-LAN connectivity • Remote access • Logical DTE (router) to logical DCE (Frame Relay switch) • Virtual Circuits (VC) are end-to-end

  5. VC(Virtual circuit) Logical circuit created to ensure reliable communication between two network devices. A virtual circuit is defined by a VPI/VCI (Virtual Path Identifier/Virtual Channel Identifier) pair Can be either permanent (a PVC) or switched (an SVC). Virtual circuits are used in Frame Relay and X.25.

  6. PVC (Permanent Virtual Circuit) Virtual circuit that is permanentlyestablished. PVCs save bandwidth associated with circuit establishment and tear down in situations where certain virtual circuits must exist all the time.

  7. SVC (Switched Virtual Circuit) Virtual circuit that is: • dynamically established on demand • torndown when transmission is complete. SVCs are used in situations where data transmission is sporadic. It is not used in Frame Relay, but it has been specified.

  8. FRAD (Frame Relay Access Device) Any network device that provides a connection between a LAN and a Frame Relay WAN. Frame Relay Service and Circuits: • Data-Link Connection Identifier (DLCI) • Committed information rate (CIR) • Access rate is 56 kbps, 64 kbps, or 1.544 Mbps • One physical access interface • One logical hop to any point • Implemented mostly as a carrier-providedservice • Can also be used for privatenetworks

  9. DLCI(Data-link Connection Identifier) A 'localidentifier' between the DTE and the DCE, it identifies the logical connection that is multiplexed into the physical channel. Value that specifies a PVC in a Frame Relay network. In the basic Frame Relay specification, DLCIs are 'locally significant'. In the LMI extended specification, DLCIs are 'globally significant' (DLCIs specify individual end devices). The FR Switchmaps the DLCIs between each pair of routers to create a PVC. DLCI values are typically assignedby the Frame Relay serviceprovider

  10. LMI(Local Management Interface) A signallingstandard between the CPE device and the FR Switch that is responsible for managing the connection and maintaining"status" between the devices. Set of enhancements to the basic Frame Relay specification. LMI includes support for: • 'keepalive mechanism', which verifies that data is flowing; • 'multicast mechanism', which provides the network server with its local DLCI and the multicast DLCI; • ‘globaladdressing', which gives DLCIs global rather than local significance in Frame Relay networks; • 'status mechanism', which provides an on-going status report on the DLCIs known to the FR Switch.

  11. LMI The main purpose for the LMI process is: (management of the connection) • PVC status - What is the operational status of the various PVCs that the router knows about? • Transmission of 'keepalive' packets - Insure that the PVC stays up and does not shut down due to inactivity. Three types of LMIs are supported: • cisco - LMI type defined jointly by Cisco, StrataCom, Northern Telecom, and DEC (frame relay forum) • ansi - Annex D defined by ANSI standard T1.617 • q933a - ITU-T Q.933 Annex A LMI encapsulation types: • IETF Encapsulation Type • Cisco Encapsulation Type

  12. Glossary CIR (Committed Information Rate - The rate at which a Frame Relay network agrees to transfer information under normal conditions, averaged over a minimum increment of time. CIR, measured in bits per second, is one of the key negotiated tariff metrics. Local access rate - The clock speed (port speed) of the connection (local loop) to the Frame Relay cloud. It is the rate at which data travels into or out of the network. Committed Burst (Bc) - The maximum number of bits that the switch agrees to transfer during any Committed Rate Measurement Interval (Tc). Excess Burst - The maximum number of uncommitted bits that the Frame Relay switch will attempt to transfer beyond the CIR. Excess Burst is dependent on the service offerings available by your vendor, but is typically limited to the port speed of the local access loop.

  13. More Terms ECN (Forward explicit congestion notification) - When a Frame Relay switch recognizes congestion in the network, it sends an FECN packet to the destination device indicating that congestion has occurred. BECN (Backward explicit congestion notification) - When a Frame Relay switch recognizes congestion in the network, it sends a BECN packet to the source router instructing the router to reduce the rate at which it is sending packets. DE (Discard Eligibility indicator) - When the router detects network congestion, the FR switch will drop packets with the DE bit set first. The DE bit is set on the oversubscribed traffic; that is, the traffic that was received after the CIR was met.

  14. Connection-Oriented Services (Three Phases) • ConnectionEstablishment • a single path between source and destination devices is determined • resources reserved to ensure a consistent rate of service • DataTransfer • data transmitted sequentially over the established path • packets arrive at the destination in the order sent • ConnectionTermination • terminate the connection between source and destination

  15. Subinterfaces Frame Relay 'without' SubInterfaces: • Early implementation of Frame Relay Technology required that a router (DTE device) must have a WAN serial interface for every (PVC) permanent virtual circuit. Frame Relay SubInterfaces: • Subinterfaces are required to configure multipleDLCIs on a singlerouterinterface. • This involves logically dividing a single physical WAN serial interfaceintomultiple virtual subinterfaces • A single router interface can now service many remote locations through individual unique suberinterfaces • Each subinterface is considered a uniquenetwork and a uniqueDLCI number

  16. Routing Updates Reachability Issues with Routing Updates Reducing routing loops by: • SplitHorizon - Routing updates received at central router cannot be advertised out the same physical interface to other routers. • Not a problem if there is only a single PVC on a physical interface, because this would be more of a point-to-point connection type. • When running multiple PVCs over a single physical interface, this can be a big issue. • A singlephysical interface can be split into multiplelogical interfaces (Subinterfaces). • Subinterfaces can resolvesplithorizon issues. • Routingupdates can be sent out subinterfaces as if they were separate physical interfaces.

  17. Good luck on the test !!!

More Related