1 / 22

Cingular Radio Parameters Consistency Check (C 3 ) Tool

Cingular Radio Parameters Consistency Check (C 3 ) Tool. Cingular Consistency Check (C 3 ) Tool - Overview.

ranae
Download Presentation

Cingular Radio Parameters Consistency Check (C 3 ) Tool

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Cingular Radio Parameters Consistency Check (C3) Tool

  2. Cingular Consistency Check (C3) Tool - Overview • The tool runs a parameter consistency check on the RNC configuration against the RND CIQ (radio configuration data) and a parameter list (National Parameter Baseline which contains Ericsson recommended and Cingular required parameter settings) • The tool is also capable to perform SC planning analysis, missing neighbor analysis and truncations of the monitored list analysis • The tool does not provide any support for consistency check on RBS configutarion, for this reason all the RBS parameters in the RND CIQ are not checked

  3. Cingular Consistency Check (C3) Tool - Overview From Sonar web server KgetAll file (RNC config.) • Neighbor Analysis: SC collision and Monitored Set Truncation analysis (on RND-CIQ data) • CIQ Check: missing neighbors & CIQ Parameter consistency check (RND-CIQ vs KgetAll comparison) • Parameter Check: national baseline parameter consistency check (National Parameter Baseline vs KgetAll comparison) Market specific RND-CIQ C3 Tool National Parameter Baseline

  4. Cingular Consistency Check (C3) Tool - Overview The Options area The Import area The Status area

  5. Cingular Consistency Check (C3) Tool The Import area • Import multiple KgetAll files of different RNCs in the market • Import a list of default/recommended parameter values (baseline) • Import RND-CIQ file (latest template R6A4)

  6. Cingular Consistency Check (C3) Tool The Import area Import KgetAll files Import CIQ file Import Parameter List file

  7. Cingular Consistency Check (C3) Tool The Option area Options for neighbour analysis Cnsistency check against CIQ options Parameter List consistency check options

  8. Cingular Consistency Check (C3) Tool The Option area • The Option Area contains three different type of consistency check: • Neighbor Analysis • CIQ Check • Parameter Check • Neighbour Analysis is based on RND-CIQ data and includes: • Repeated SC analysis in the monitored set (w max AS size 3 or 4) (SC collision detection) • Monitored Set Truncation analysis for all the active set combination (w max AS size 3 or 4) • Detailed SC collision analysis w info for each possible AS combination (w max AS size 3 or 4)

  9. Cingular Consistency Check (C3) Tool The Option area • CIQ Check is based on the comparison between RND-CIQ & Network configuration (KgetAll file) and includes: • Check neighbours (utran/gsm or both) • Consistency Check on all the parameters included in the RND-CIQ • Check external GSM cells definition • Parameter Check is based on the comparison between National Parameter baseline & Network configuration (KgetAll file) and includes: • Check against Cingular Baseline • Check against Ericsson default values (upon availability on this info) • Check against Ericsson recommended values (upon availability on this info) • Check against recommended when available otherwise uses default (Mixed)

  10. Cingular Consistency Check (C3) Tool The Status area Start neighbour analysis Current operation information textbox Start CIQ check Start parameter list check

  11. Cingular Consistency Check (C3) Tool The Status area • Each Start button will generate a different xls file with multiple worksheet with the results of the check. • The status window allows the user to know the current operation the tool is performing

  12. Cingular Consistency Check (C3) Tool File Type Requirement • RNC dump: Moshell dump using kget all command • CIQ file: RND CIQ file (latest version R6A4) • Parameter List: any excel files with the parameter information on the second worksheet (any name) having the following exact column names: • “MoC Name”: name of the MO class • “Parameter Name”: name of the parameter • “Default Value”: default value (using the MoM convention) • “Recommended Value”: recommended value (using the MoM convention • “Node Id”: (optional) indicates the type of node (RNC, RXI, RBS etc…) if missing assumes that all the parameters are RNC

  13. Cingular Consistency Check (C3) Tool Responsibility Matrix • It is a market RF team lead responsability to run the Radio Parameter consistency check. • It is a market RF team lead responsability to maintain the RND CIQ database and ensure its accuracy. • It is a national Configuration Management team responsability to maintain the radio parameter list (national baseline), which is based on Ericsson recommended parameter settings and on Cingular requirements.

  14. Output Examples

  15. Cingular Consistency Check (C3) Tool Example of results – Parameter Check

  16. Cingular Consistency Check (C3) Tool Example of results – SC analysis It shows how many times(hits) (of the total combination of AS) this cells have been in the neighbour set with other cells having the same SC Level1, 2 and 3 refer to the AS size. So for example the first row says that the cell DXU4010X has been seen 11 times colliding with DXU4153Y when only one cell was in the AS. The level is then a measure of the severity of the collisions (the lower the level the higher the severity). Level 1 collision means a cell has neighbors defined with the same SC !!!!!

  17. Cingular Consistency Check (C3) Tool Example of results – SC detailed analysis It shows for each AS combination which cells have the same SC in the neighbour list

  18. Cingular Consistency Check (C3) Tool Example of results – Truncation It shows for each max AS combination the total number of cells in the neighbour list

  19. Cingular Consistency Check (C3) Tool Example of results – CIQ check

  20. Cingular Consistency Check (C3) Tool Example of results – CIQ check neighbours

  21. Cingular Consistency Check (C3) Tool Example of results – CIQ check neighbours

More Related