1 / 4

Panel Guard: Breaker Panels from 1600A to 4000A

Main breaker switchboard platform for 415VAC through 600VAC Three Phase. Supporting a main breaker and up to 40 feeders in one of the most compact and cost competitive platforms on the market. https://raptorpowersystems.com/products/breaker-panels.

Download Presentation

Panel Guard: Breaker Panels from 1600A to 4000A

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Breaker Panels from 1600A to 4000A Panel Guard

  2. Breaker Panels from 1600A to 4000A Panel Guard UL 891 Certified Switchboards 1600A to 4000A Main breaker switchboard platform for 415VAC through 600VAC Three Phase. Supporting a main breaker and up to 40 feeders in one of the most compact and cost competitive platforms on the market. Multiple feeder breaker size options and combinations available, with bus ampacities from 1600A to 4000A. MVT connec- tions available by direct bus or by cable. panel shown with deadfront Product Details • 415 or 600VAC, 3PH, 4W (90”x 60”x 36”) • 1600A to 4000A main breaker / bus ratings • Up to 3,000kVA transformer connection • Main lug only option also available • High density (up to 40 x 100AF) branch feeders • Feeder ranges: 100AF, 150AF, 250AF, 400AF, 600AF, 800AF • Feeder trip type: Thermal Mag or Electronic Trip • Interrupt Ratings: • 65kAIC @ 415 / 480VAC • 50kAIC @ 600VAC panel shown without deadfront Designed & Assembled in the USA Raptor Power Systems | (800) 258-0129 | info@raptorpowersystems.com

  3. Breaker Panels from 1600A to 4000A Panel Guard 480VAC – 600VAC BOS Equipment Custom Throated Transformer Connections Breaker Panel Enclosure Styles Panel Guard Breaker panels are available in indoor NEMA 1, and outdoor NEMA 3R enclosures to ensure maxium compatabilty with most applications. Internal Trough Bus Connection 4000A Trough is certified UL 870 Pictured above: Single 600VAC, 4000A, UL / NEMA 3R UL 891 switchboard with close coupled bus connection to 3000kVA MV transformer. Rear view of switchboard with throated connection opening Product Details • • or optional UL listed ERIFLEX flexible bus bars • Steel equipment skids with MVT & Switchboard combined available MVT / block sizes: Up to 3,000kVA, Available with bare copper bus bars for MVT connection, Designed & Assembled in the USA Raptor Power Systems | (800) 258-0129 | info@raptorpowersystems.com

  4. Breaker Panels from 1600A to 4000A Panel Guard Specifications Alignment Service Minimum Interrupt Ra�ng Bus Amps Bus Bracing Interrupt Ra�ng 50kAIC (65kAIC @ 480VAC) Neutral Amps Bus Material Ground Bus Mat Entry Point Incoming Wire Size Ountgoing Entry Enclosure Type Dimensions Weight Front Access Upt o 600VAC 3 Phase 4W 50kAIC (65kAIC @ 480VAC) 1600A - 4000A General Bus Specifica�ons None Copper .25 x 2" (qty 2) Bo�om Up to 350MCM, Cu/Al, landing on MCCBs directly Rear, hard buss connec�on to MVT through UL 3R trough, or direct cable connec�on to MVT. NEMA 1 or NEMA 3R (non walk-in) flat roof 90" x 60" x 36" 2500lbs Input Output Structure Raptor Power Systems | (800) 258-0129 | info@raptorpowersystems.com

More Related