1 / 27

Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

This presentation outlines the verification and validation process of Geant4 photon processes with SANDIA, EPDL97, and NIST databases. It includes the identification of data libraries, comparison of migrated processes, and verification using analytical approximations and experimental data. The validation includes comparisons of cross-sections and mean free paths for various models and materials. Findings and conclusions based on the validation are discussed.

rcasey
Download Presentation

Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases Zhang Qiwei INFN-LNS/CIAE 14th Geant4 Users and Collaboration Workshop Catania,Italy October 15,2009

  2. Outline • Verification before of validation • Identification of data libraries for validation SANDIA EPDL97 NIST • Validation of the Geant4 photon processes with respect to the data libraries Verification for migrated processes (migrated vs non migrated) for Livermore & Penelope Verification for migrated processes: comparison with Standard physics processes

  3. G4PhotoElectricEffect (standard default) G4PhotoElectricEffect G4LivermorePhotoElectricModel G4PenelopePhotoElectricModel Migration of low energy EM processes • From version 9.2 of Geant4, the low energy EM processes and models (Livermore & Penelope) have been migrated to standard EM software design • A physical process can be simulated according to several models • models can be alternative and/orcomplementary on certain energy ranges

  4. Photoelectric effect • Compton scattering • Gamma conversion (pair production +triplet production) • Rayleigh scattering • Photon processes: • Material: elements (15) compounds : Air Water NaI

  5. Verification for migrated processes (a) Comparison of Mean Free Path (MFP) for the migrated processes: G4EmCaculator object • G4LivermoreXxxModel.cc • G4PenelopeXxxModel.cc vs for non migrated processes: Changed the Geant4 code • G4LowEnergyXxx.cc • G4PenelopeXxx.cc

  6. Comparison of MFP for Livermore model (Pb) photoelectric compton Comparison of MFP for Livermore model (Water) gamma conversion rayleigh

  7. Comparison of MFP for Penelope model (Water) photoelectric compton Comparison of MFP for Penelope model (Ne) gamma conversion rayleigh

  8. Verification for migrated processes (b) Comparison of Mean Free Path (MFP) for the migrated processes: G4EmCaculator object • G4LivermoreXxxModel.cc • G4PenelopeXxxModel.cc vs for Standard processes: G4EmCaculator object • G4Xxx.cc

  9. Comparison with Standard physics processes(Ne) photoelectric compton Comparison with Standard physics processes(Pb) gamma conversion rayleigh

  10. Identification of data libraries for validation • SANIANational Laboratories provide analytical approximations to cross sections for both photoelectric absorption of photons by atoms and incoherent scattering of photons by atoms • Analytical Approximations for X-Ray Cross Section III • EPDL97 (Evaluated Photon Interaction Data Library) designed to meet the needs of users at Lawrence Livermore National Laboratory for use in photon transport calculations • http://www-nds.iaea.org/epdl97/ • The National Institute of Standards and Technology (NIST) maintains a large number of databases about photon-atom interactions ( Form Factors, Attenuation & Scattering Tables, NIST X-Ray and Gamma-Ray Attenuation Coefficients and Cross Section) • http://physics.nist.gov/PhysRefData/contents.html Standard processes Livermore processes

  11. Comparison of experimental libraries (H) photoelectric compton Comparison of experimental libraries (Ca) gamma conversion rayleigh

  12. Comparison of experimental libraries (Air) photoelectric compton Comparison of experimental libraries (NaI) gamma conversion rayleigh

  13. Validation of the Geant4 photon processes with respect to the libraries based on experimental data • SANDIA • EPDL97 • NIST Retrieve the cross section : G4EmCalculator object G4EmCalculator emCal emCal.ComputeCrossSectionPerAtom (energy,gamma,emName,Z,A,cut) Or emCal.ComputeCrossSectionPerVolume (energy,gamma,emName,material,cut)

  14. Comparison of XS per Atom between SANDIA and Geant4 (O photoelectric)

  15. Comparison of XS per Atom between SANDIA and Geant4 (Ba compton)

  16. Comparison of XS per Atom between EPDL97 and Geant4 (Al photoelectric)

  17. Comparison of XS per Atom between EPDL97 and Geant4 (Fe compton)

  18. Comparison of XS per Atom between EPDL97 and Geant4 (Se gamma conversion)

  19. Comparison of XS per Atom between EPDL97 and Geant4 (H rayleigh)

  20. Comparison of XS per Atom between NIST and Geant4 (Nb photoelectric)

  21. Comparison of XS per Atom between NIST and Geant4 (Ag compton)

  22. Comparison of XS per Atom between NIST and Geant4 (I gamma conversion)

  23. Comparison of XS per Atom between NIST and Geant4 (Cu rayleigh)

  24. The result in detail: https://twiki.cern.ch/twiki/bin/view/Geant4/LoweValidation • In Penelope Rayleigh Model,G4EmCalculator object just can retrieve the XS per Atom (energy > 1GeV) • Retrieve the XS directly with the model’s methods G4PenelopeRayleighModel* ray = new G4PenelopeRayleighModel(); xs = ray->CrossSectionPerVolume (material,gamma,energy,cut);

  25. Comparison of XS per Atom betweenNIST and Penelope Model (rayleigh) G4EmCalculator object Direct methods Cu Ag

  26. conclusions • The Standard model cross sections originate from SANDIA, their differences are small; • In the similar case,the Livermore model cross sections are in good agreement with EPDL97; • The cross sections of most photon models agree with NIST within 10% except Penelope rayleigh model; • The results of two methods (G4EmCalculator object and direct methods) are agreement except Penelope rayleigh model; It looks like Penelop rayleigh calculations by the G4EmCalculator are performed only above 1 GeV, namely outside the Penelope range. It is probably a limit/problem of the G4EmCalculator

  27. Thank you !

More Related