1 / 18

Study on Variable Speed Wind Turbines’ Capabilities for Frequency Response

Study on Variable Speed Wind Turbines’ Capabilities for Frequency Response. Germán Claudio Tarnowski - Technical University of Denmark & Vestas Wind Systems A/S Jacob Østergaard - Technical University of Denmark Poul E. Sørensen - Risø National Laboratory, Denmark

rea
Download Presentation

Study on Variable Speed Wind Turbines’ Capabilities for Frequency Response

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Study on Variable Speed Wind Turbines’ Capabilities for Frequency Response Germán Claudio Tarnowski - Technical University of Denmark & Vestas Wind Systems A/S Jacob Østergaard - Technical University of Denmark Poul E. Sørensen - Risø National Laboratory, Denmark Philip C. Kjær - Vestas Wind Systems A/S, Denmark

  2. Outline • Introduction: variable speed wind turbine frequency response for grid frequency stability. • Simulation set-up • Small/low inertia power system with wind power • Models • Simulation cases: generation trip • Conventional generation only (Base Case) • Wind power Without inertia response • Wind power + Inertia response • Wind power + Inertia response + Primary frequency control • Conclusions & remarks

  3. Introduction • Grid frequency variations  Imbalance between generation and consumption • Wind Turbine Frequency Response: Change in the wind turbine active power output as response to a change in the grid frequency • Inertia response (power from rotating kinetic energy) • Primary frequency control (power from wind reserve) • Study on capabilities of WT-DFIG for providing controlled frequency response during frequency drop in a small/low inertia power system, combining inertia response and primary frequency control

  4.  = 0 CP (,)  = 10 Simulation set-up: WT-DFIG model Drive train 3rd order DFIG Converter control: active and reactive power. Aerodynamics Pitch control: rotational speed

  5. f (-) PDROOP(+) Power Change Wind turbine frequency response • Inertia response (inertia emulation) • Primary frequency control (Droop) • Plant power reserve (reserve factor) WT control block

  6. Simulation set-up: Power system Conventional generators 50 MW Generation Loss (20%) Wind Farm replacing ST1 30% Wind Power Penetration

  7. Simulation set-up: Conventional generatorsmodel Model for Steam Power Plant and Hydro Power Plant

  8. Simulation cases: Inertia response from wind turbine Grid with conventional generators Grid without inertia response from WT Grid with inertia response from WT 50 MW Generation Loss (20%)

  9. Results: Grid frequency Grid Frequency [Hz] Conventional generators case WT without inertia response case WT with inertia response case Frequency gradient

  10. Results: Power plants electric power output Power [MW] Steam turbine ST2 Conventional generators Wind power without inertia response Inertia response from wind power Steam turbine ST1 Wind turbine Hydro turbine

  11. WT inertia response Powers [pu] Torques [pu] Rotational speed [pu] Pitch angle [deg]

  12. Simulation cases: inertia response + primary frequency control Droop 16% + Inertia response Droop 10% + Inertia response Droop 9% + Inertia response (Instability) 50 MW Generation Loss (20%)

  13. Results: Grid frequency Grid Frequency [Hz] Conventional generators WT Droop 16% + Inertia response WT Droop 10% + Inertia response Frequency gradient

  14. Results: Power plants electric power output Power [MW] Steam turbine ST2 Conventional generators Droop 16% + Inertia response Droop 10% + Inertia response Steam turbine ST1 Wind turbine Hydro turbine

  15. Turbine droop 10% + inertia response Powers [pu] Torques [pu] Rotational speed [pu] Pitch angle [deg]

  16. Turbine droop 9% + inertia response. Instability. Powers [pu] Torques [pu] Rotational speed [pu] Grid Frequency [Hz]

  17. Conclusions & remarks • Variable speed WTs’ capabilities for inertia response and primary frequency control was studied • Suitable control systems for variable speed WTs need to be developed for integrating high amounts of wind power in the grid • Grid frequency stability can be improved combining WT inertia response and primary frequency control • Instability in wind turbines with bad settings of primary control and inertia response: Capability depends on the combination of droop value, power reserve and inertia emulation.

  18. Thank you for your attentionGermán C. TARNOWSKIgct@elektro.dtu.dk