280 likes | 455 Views
THE UN I VERS I TY OF ATHEN A. Aristotelis Vasiliadis Athanasios Balafoutis Riza Fatih Mendilcioglu Ludovic Vanquin. OUTLINE. INTRODUCTION – ARCHITECTURAL CHARACTERISTICS CURRENT STATUS LIGHTING CONCEPT – DECISIONS LUMINAIRES FINAL RESULT
E N D
THE UNIVERSITY OF ATHENA Aristotelis Vasiliadis Athanasios Balafoutis Riza Fatih Mendilcioglu Ludovic Vanquin
OUTLINE INTRODUCTION – ARCHITECTURAL CHARACTERISTICS CURRENT STATUS LIGHTING CONCEPT – DECISIONS LUMINAIRES FINAL RESULT IF THERE WAS MORE TIME.. – THINGS TO CONSIDER ABOUT
1.INTRODUCTION – ARCHITECURAL CHARACTERISTICS • The main building of the University of Athens : • designed by the Danish architect Hans Christian Hansen • constructed between 1839 and 1842 Today : • headquarters of the University of Athens • houses the offices of the Rectorate, the Juridical Department, the Archives and the Ceremonial Hall for official ceremonies refering to the University community. • INTRODUCTION – ARCHITECTURAL CHARACTERISTICS • CURRENT STATUS • LIGHTING CONCEPT – DECISIONS • LUMINAIRES • FINAL RESULT • IF THERE WAS MORE TIME.. – THINGS TO CONSIDER ABOUT
1. INTRODUCTION - ARCHITECTURAL CHARACTERISTIC OF THE BUILDING • The Building : • Neoclassical style with a double T or H shape • Two symmetrical courtyards • Strictly symmetrical facade with an Ionian-style entrance • Entrance emphasized by two heavy columns with impresive capitals, similar architecture to the Propylaea of Acropolis • Classical fresco on the inner walls designed by the Bavarian Karl Rahl and painted after 1888 by Eduardo Lebiedzky
The Exterior : • Five statues stand in front of the building, commemorating important figures of the modern Hellenic history (William E. Gladstone, RigasPheraios of Velestino, Gregorios V,Count, loannis Kapodistrias, Adamantios Korais). • Exterior consists of stone and green areas, formatting a circular entrance space. Two marble fountains at the front of the entrance complete the scene. • There also two paths that climb up sideways,at the front of the building.
2. CURRENT LIGHTING STATUS SPOT PROJECTORS FOR THE FRESCO LINEAR LIGHTING OF THE UPPER TRIANGLE OF THE BUILDING TRADITIONAL LUMINAIRES FOR THE SURROUNDINGS PATHWAY MARKERS (NOT WORKING)
2. CURRENT LIGHTING STATUS (Cont.) * Actually, we saw no light nor water in the fountains!!
3. LIGHTING CONCEPT - DECISIONS Aims and goals: • Emphasize the functionality of the building ( aplace for learning, communication and intellectual exchanges). • Show the historical and cultural characteristics of building. • Use the lighting to create an attractive atmosphere.Visitors are invited to feel attracted and curious to explore. Emphasize the hug-shaped entrance. • Arrange the surroundings to create a friendly and calming place. Emphasize the green space, highlight the fountains and the statues. • Finally: Playing with columns and fresco, giving the impression of a book that is ready to reveal its content but not without effort.
3. LIGHTING CONCEPT – DECISIONS (Cont.)General luminaire arrangement
AmazonLED² Ground marker usedtoshowthehugshape of theentrance Type: BBC200 (230 V, class II version) BBC201 (24 V, class IIIversion) Lightsource: Integral LED-module Power(+/-10%) BBC200: < 2 W BBC201: < 1 W Luminous flux: Warm white (WW): 20 lmBlue (BL): 5 lm CorrelatedColorTemperature : 3000 K ColorRenderingIndex: 80 Maintenance of lumen output: - L70 35,000 hours at 35ºC Operating temperature range: -20 to +35ºC Driver BBC200: integrated BBC201: not integrated Mains voltage BBC200: 220-240 V / 50-60 Hz BBC201: 24 V DC Inrush current: 100 mA at 14 ms Optical cover: Opal cover Material: Ringstainless steel, grade 316x Optical cover: polycarbonate, opal, UV-stabilized Connection Delivered with mains cable, 20 cm of length Installation: Ground recessed Cable gland M20 Accessories: Tube for installation in concrete/ asphalt, ZBC200 TUBE Pack of 10 transformers 230/24 V, EBC201 PSU 230/24V (10 pieces) 1 transformer 230/24 V, EBC201 PSU 230/24V
C-Splash 2 Underwatercolorluminaireto be used in thefountains Type: BCP468 Light source: Integral LED-module Power : 25 W Beam angle:10º (clear lens) or 22º (frosted lens) Luminous flux:583 lm (10º), 515 lm (22º) Luminaire efficacy:20.6 lm/W (frosted lens) / 23.3 lm/W (clear lens) Maintenance of lumen output :- L50 50,000 hours at 50ºC Operating temperature range: -20 to +50ºC Driver Integrated Power/Data Supply:PDS-60 24 V; supply for indoor and outdoor applications PDS-150e; supply for Ethernet and DMX installations Mains voltage: 24 V DC Dimming Digital via PDS-60 24V or PDS-150e Material Housing: cast brass Lens: clear or frosted tempered glass Connection: 18.3 m unified power/data cable, standard, 45.7 m maximum 121.9 m total per power/data supply Installation: Surface mounted
eW Burst Compact Powercore Spot luminaireusedtoaccentthetrees TypeBCP463 Light source Non-replaceable LED module Available in white (2700K or 4000K) as well as 4 solid colors (Red, Blue, Green, Amber) Power 20 W max. at full output Beam angle 8º primary optic 14, 23 or 41º spread lenses 10 x 41º asymmetric spread lens Luminous flux 624 lm (8º), 543 lm (14º), 540 lm (23º), 520 lm (41º), 557 lm (10 x 41º) - 2700 K 812 lm (8º), 685 lm (14º), 674 lm (23º), 646 lm (41º), 695 lm (10 x 41º) - 4000 K Correlated Color Temperature 2700 K, warm white 4000 K, neutral white Color Rendering Index > 82.6 (2700 K) or > 80.6 (4000 K) Maintenance of lumen output - L50 120,000 hrs at 25ºC Maintenance of lumen output - L70 90,000 hrs at 25ºC 45,000 hrs at 50ºC Operating temperature range -40 to +50ºC operating -20 to +50ºC start-up Driver Built-in Mains voltage 100-277 V AC / 50-60 Hz Optic Symmetrical and asymmetrical with spread lenses Maintenance No internal cleaning required
iW Burst Compact Powercore Spot luminaire of varıable CCT used to accent: • - the fresco • - the upper part of the building • - the statues • - the columns of the entrance Type BCP464 Light source Non-replaceable LED module Beam angle 8° primary optic 14°/ 23°/ 41° spread lenses 10 x 41° asymmetric spread lens Correlated Color Temperature Warm white, 2700 K to cool white, 6500 K Operating temperature range -40 to +50°C operating -20 to +50°C start-up Driver Separate, to be ordered separately Via Data Enabler Pro (DMX or Ehernet) Mains voltage 100-240 VAC / 50-60 Hz via Data Enabler Pro Controls system input Philips full range of controllers, including Light System Manager and iPlayer3, or third-party DMX controllers Optic Symmetrical and asymmetrical with spread lenses Material Housing: high-pressure, die-cast aluminum, powder-coating finished Glass: tempered Mounting bracket: high-pressure, diecast aluminum, powder coating finished
6. IF THERE WAS MORE TIME.. – THINGS TO CONSIDER ABOUT Examine different scenarios Examine lighting with respect to the two other buildings which consist Athens's Trilogy Full technical and economical analysis, regarding various different types of luminaires Exact photometric computations: how much lux needed and how much are finally delivered? (insert virtual surfaces in Relux) Regard mistakes done and have feedback Examine side views .. and maybe have a better presentation!