Presentation Outline • Summary and Overall System Block Diagram • DC Subsystem • Maximum Power Point Tracking • Boost Converter Testing • AC Subsystem • Schedule • Component List
Project Summary • Supplies DC and AC Power • Photovoltaic Array • Boost Converter to step up PV voltage • Maximum Power Point Tracking • DC-AC converter for 120Vrms • LC filter
DC Subsystem • Boost Converter • Maximum Power Point Tracking (MPPT) System
DC Subsystem Requirements • The boost converter shall accept a voltage from the photovoltaic cells. • The input voltage shall be 48 Volts. • The average output shall be 200 Volts +/- 25 Volts. • The voltage ripple shall be less than 3 Volts • The boost converter shall perform maximum power point tracking. • The PWM of the boost converter shall be regulated based on current and voltage from the PV array. • The efficiency of the MPPT system shall be above 85%.
DC Subsystem Key Components • MOSFET • Vds = 250V • Id = 110A • Pdiss = 694W • Heatsink • Inductor • 1mH 25A • 500uH 35A • Gate Driver • MOSFET or IGBT • 2.5A 500V • Solar Panel x 4 • 50W • 12V
DC Subsystem Components • Current Sensor • 30A • 63-69 mV/A • Sensing Op amp • Used with voltage divider • DSP Board • TMS320F2812
MPPT • “Perturb and Observe” method • Change Boost Converter duty cycle based on change in PV power • Changing duty cycle changes the current drawn from the PV • Anytime the system is not at themaximum power point, it is notat it’s most efficient point
PV Models in Simulink • Made models of PVs using resources from the University of Colorado at Boulder • Insolation – a measure of solar energy on an area over a given amount of time. • Usually in units of W/m^2
I P V V
I V P V
Boost Converter Lab Testing • Built boost converter from components Dr. Na provided.
Boost Converter Lab Testing • 0 to 3.3V signal from DSP board controlling the MOSFET • At a switching frequency of 10kHz with a 50% duty cycle the 5V input voltage was boosted to about 10V. • Increasing duty cycle, increased Vout • Decreasing duty cycle, decreased Vout • After testing this setup we will be able to build our Boost converter circuit quickly.
DSP Board Programming • Spectrum Digital eZdsp F2812 • Texas Instruments Code Composer • Matlab/Simulink
PWM GenerationExperimental Results 80% Duty Ratio 30% Duty Ratio
AC Subsystem • Inverter • Output filter
AC Subsystem - Inverter • Inverter topology • Inverter operation • Simulations
AC SubsystemInverter Topology Inverter single phase H-bridge
AC SubsystemInverter Operation - Bipolar • A reference sinusoidal waveform is compared to a triangular carrier waveform • When the reference voltage is equal to the carrier voltage a transition in the switching signal occurs
AC SubsystemInverter Operation - Bipolar Simulation schematic
AC SubsystemInverter Operation - Bipolar Reference (blue) and carrier (red) waveforms Switching signal
AC SubsystemInverter Operation - Bipolar Inverter output. Switches from +Vd to -Vd
AC SubsystemInverter Operation - Bipolar • Switching signal is inverted and fed to other pair of switches • Switch pairs are switched simultaneously • Only one reference signal needed, but performance is poor
AC SubsystemInverter Operation - Unipolar • Two reference sinusoids are compared to a triangular waveform • Switch pairs not switched simultaneously
AC SubsystemInverter Operation - Unipolar Simulation schematic
AC SubsystemInverter Operation - Unipolar References and carrier waves Switching signal 1 Switching signal 2 Output Image source: Tian
Inverter Operation - Comparison Bipolar harmonic output Unipolar harmonic output
AC Subsystem - Output Filter • Inverter output includes switching harmonics • Filter smoothes output
AC Subsystem Requirements • The AC side of the system shall invert the output of the boost converter. • The output of the inverter shall be 120 Volts RMS. • The output shall be 60Hz +/- 0.1Hz. • The inverter output shall be filtered by a LC filter. • The filter shall remove high switching frequency harmonics. • Total harmonic distortion of the output shall be less than 15%.
AC Subsystem Key Components • Inverter switches • Gate drives • Power supplies