Wirescanner Status. Guy Crockford BE/OP LBOC 11/10/11. Content. Front End improvements Beam 1: 200MHz noise suppression Intensity limit at injection energy Bunch selection gate limitations Application Software improvements… Tools for bunch selection

reia
Download Presentation

Wirescanner Status

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Wirescanner Status Guy Crockford BE/OP LBOC 11/10/11

  2. Content • Front End improvements • Beam 1: 200MHz noise suppression • Intensity limit at injection energy • Bunch selection gate limitations • Application Software improvements… • Tools for bunch selection • Display of multiple bunch normalized emittance • General layout

  3. Beam 1: 200MHz Noise

  4. Beam 1: 200MHz noise • Source of noise not yet understood • Few opportunities for access/investigation • Remove with simple filtering technique… • For each wirescan acquisition… • Add gate to acquire noise signal in the abort gap • Subtract signal acquired from measurements in gates with beam

  5. WS measurements @ horizontal scrappingCorrection due to noise B1 profile: Noise reduced by deducting the acquisition of a bunch slot belonging to the abort gap & acquired at the same time B1 profile: ~200Hz noise hides the profile Sigma from noisy profiles Sigma from cleaned profiles Intensity curve Sigma (um) Sigma (um) Acq stamp (ns) Acq stamp (ns) • The Sigma curve follows Intensity curve in H plane. • The overall measurement spread for the corrected profiles is significantly reduced

  6. Sigma spread with filtering LHC.BWS.5R4.B1H2 Sigma

  7. Scan results with filtering

  8. Intensity limit at injection • Wire damage threshold (higher limit) • BLM trigger threshold (more sensitive) • Previously set to 2.1E13 at 450GeV • We need to scan 12+144 nominal bunches • Hitting limit at bunch intensity > 1.34E11 • Increase limit to 2.5E13 at 450GeV • Effective bunch intensity limit raised to 1.6E11

  9. Acquisition gate limitation issues • Previously acquisition gate limited to 30 bunches • Firmware bug… • Only ¼ of DAB card memory exploitable • Firmware problem solved and number of turns for 1 acquisition reduced from 1000 to 500 • Now able to set the acquisition gate to measure 156 bunches in 1 scan

  10. Tools for gate selection • Need to quickly check emittances at the start of the physics filling process • 12 bunch batch & first 144 bunch batch • Buttons added to application to select the correct batch (based on nominal filling scheme) • Buttons to save and recall user defined bunch selections to file

  11. Bunch selection options

  12. Bunch selection options 12 Bunch Batch First 144 Bunch Batch

  13. Emittance Chart Normalized Emittance vs Slot number

  14. Multiple fit calculation • Slow to calculate fits for 156 bunches • Enable multiple fit calculation for all bunches only if required Fit All profiles Fit Only Visible Profiles

  15. Settings Menu • All key settings controlled from front panel

  16. Acknowledgments • Thanks to… • BE/BI: • Ana Guerrero, Federico Roncarolo, • Mariusz Sapinski, Johnathan Emery • Fermilab LAFS: • Elliott McCrory • Thanks for your attention!

More Related