UNICO INVERTER DC

UNICO INVERTER DC. UNICO INVERTER DC. The first INVERTER technology based heat pump without external unit on the market. The new product will be available in 4 different models. 1. UNICO INVERTER DC 9 SF. 2. UNICO INVERTER DC 9 HP. 3. UNICO INVERTER DC 12 SF. 4. UNICO INVERTER DC 12 HP.

remy
Download Presentation

UNICO INVERTER DC

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. UNICO INVERTER DC

  2. UNICO INVERTER DC The first INVERTER technology based heat pump without external unit on the market The newproductwillbeavailable in 4 differentmodels 1. UNICO INVERTER DC 9 SF 2. UNICO INVERTER DC 9 HP 3. UNICO INVERTER DC 12 SF 4. UNICO INVERTER DC 12 HP

  3. UNICO INVERTER DC Maintechnologyinnovations 1. Outstanding quiet operation 2. High performance and efficiency 3. High air flow and air distribution 4. Installation • Reducedinstallationtimeneeded • High and low installationconfiguration 5. Easiermaintenance 6. Advanced air filters 7. Low ambientcontrol Design (King & Miranda)

  4. 1 – OUTSTANDING QUIET OPERATION + = Unico Inverter DC Unico Inverter DC 1 Unico Star The new Unico Inverter DC’s noise level will be half the current UNICO Star

  5. DC INVERTER Technology The inverter control system constantly regulates the compressor motor speed, adapting it to the actual cooling or heating needs of the room 2 – HIGH PERFORMANCE Inverter technology Max Comfort = Keeps the set temperature without oscillations Reaches the set temperature faster Low energy consumption (reduction up to 30%) Low noise level

  6. 2 – HIGH PERFORMANCE

  7. 2 – HIGH PERFORMANCE

  8. 2 – HIGH PERFORMANCE Cooling UNICO INVERTER vs Competitors Classe A EER Kw

  9. Heating UNICO INVERTER vs Competitors 2 – HIGH PERFORMANCE Classe A Classe B COP Kw

  10. 3 – HIGH COMFORT • INCREASED AIR FLOW 520 cm/h • IMPROVED AIR DISTRIBUTION The air distribution has been improved increasing the size of the air outlet to 690 x 60 mm

  11. UNICO INVERTER UNICO STAR 4 - INSTALLATION Can be installed high wall or low wall Can be installed high wall or low wall • FOR HIGH WALL INSTALLATION • Change the position of the air outlet flap, and press a key on the LED panel • FOR HIGH WALL INSTALLATION • Dismount plastic shell • Invert position of air outlet parts • Move LED and fan cap Installazione bassa TIME NEEDED 1 minute TIME NEEDED 20 minutes Installazione alta Particolare flap uscita aria

  12. 4 – INSTALLATION • Suggested holes are of 202 mm Ø for higher performances, but the unit can works with 162mm Ø holes as well. Unico Inverter DC back

  13. It is very easy to operate the unit with 200 mm holes. The unit is factory fitted to work with 160 mm holes, if necessary. • First hole: remove the pre-cut plastic 4 – INSTALLATION • Second hole: behind the rear panel there is a polistyrene cylinder that reduces the size of the hole. Simply remove it. The distance between the center of the holes remains the same as the UNICO Star. This easily allows replacing old Unico Star units with the new Unico Inverter.

  14. The minimum top/bottom and side allowances have been reduced. Unico Inverter can be installed in small niches where it was not possible to install Unico Star. 4 – INSTALLATION

  15. The accessibility to the internal parts have been improved. It is easier to dismount and service the single components of the unit. 5 – Easiermaintenance REAR PART FRONT PART

  16. REAR PART 5 – Easiermaintenance The back of the unit is made by two panels LEFT PANEL Encloses the: - coil zone - compressor - drain exhaust system RIGHT PANEL Encloses the condenser fan group,. Removing some screws the whole fan group can be removed to be more easily serviced.

  17. FRONT PART 5 – Easiermaintenance The front part has a big frontal panel. When you remove it, you find two smaller panels. LEFT PANEL Removing it you can access to the electric board RIGHT PANEL Removing it you can access to - compressor - external coil probe - drain exhaust system

  18. 6 – ADVANCED AIR FILTERS • Electrostatic filter: removes small particles and smoke, dust, pollen, pet hair, preventing allergy issues • Active carbon filter: removes smells and deactivates harmful gases Cleaning: The air inlet grills are very easy to dismount Air inlet-outlet flaps closed Air inlet-outlet flaps open

  19. 7 – LOW AMBIENT CONTROL UNICO Inverter can work in cooling mode with outside temperature up to -10C°! This makes UNICO a perfect solution for server rooms.

  20. TECHNICAL DATA NB: all the data shown in thispresentationmustbeconsideredaspreliminary

  21. ACCESSORIES IN THE BOX • TEMPLATE • 2 INTERNAL FLANGES • PAIRS OF EXTERNAL GRILLS (200 mm) • NEW PP SHEETS TO USE FOR 200 mm HOLES (but suitable for 160mm holes as well)