Status on MONALISA. presented by D. Urner 6 th stabilization day 9. June 09. Progress on mechanical setup. Double bellow system:. Active Double Bellow. to compressed Air supply (~2.0 bar). SMC ECC-PNAL2 Controller. SMC ITV1050 Pressure Regulator. SMC PSE510 Pressure Sensor.
E N D
Status onMONALISA presented by D. Urner 6th stabilization day 9. June 09
Progress on mechanical setup • Double bellow system:
Active Double Bellow to compressed Air supply (~2.0 bar) SMC ECC-PNAL2 Controller SMC ITV1050 Pressure Regulator SMC PSE510 Pressure Sensor • Idea: Generated Force is proportional to sum of pressure in inner and outer bellow system. • Find Point where force is zero • Use commercial control system. Vent SMC PSE511 Pressure Sensor ~1.4 bar pressure Vacuum
Progress on mechanical setup • Double bellow system: • development geared towards minimal force system • development with Platine Prcision Ltd. started Sep 08 • full assembly of double bellow to double flanges this week • shipped to Oxford by end of week
FEA shows very high resonance frequencies 2cm aluminium plate bolted to M30 taped holes in Shintake table Entire structure made from aluminium. Bellows: actual bellows: stainless steel 316L flanges: stainless steel: 304L 1st mode frequency: 266Hz. 1st mode frequency:162 Hz. Mechanical Vacuum system:
How to insert optics • Insert optics platform • rests on very thin aluminium floor • essential a square piece of carbon-fibre loaded peak (plastic) holding retro-reflectors • easy to change to different (optics) geometries
Calibration Study “Calibration” = Where are these components located on their mounting plate? Shintake Monitor mounting plate QD0 mounting plate • Does system self-calibrate? • This means: calibration by making measurements at many locations. e.g: Photogrammetry does this • Can partially self-calibrate • Some DOF poorly determined • What is the effect of calibration errors? • Effect is to introduce a scale error into displacement measurements • Simulated a “minimal” calibration scenario: 1mm uncertainty in component locations 0.3% scale error for vertical motion
Calibration Study “Calibration” = Where are these components located on their mounting plate? Shintake Monitor mounting plate QD0 mounting plate • What is the effect of calibration errors? • Effect is to introduce a scale error into displacement measurements • Simulated a “minimal” calibration scenario: • e.g vibrations with amplitude 1μm would be limited in reconstructed accuracy to 3nm from calibration • a long-term shift of 100 μm would be limited in reconstructed accuracy to 300nm 0.3% scale error for vertical motion 1mm uncertainty in component locations
MONALISA at CLIC • Start with 3 vertical lines • launch heads will be produced for KEK and CLIC by end of year • Need vertical tubes, ideally of 200 mm diameter • Later add horizontal measurement • Need 200 mm horzontal tube • As much space at intersection as we can get.