1 / 34

Xtra-Guard Performance Cable

rianne
Download Presentation

Xtra-Guard Performance Cable

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    1. Xtra-Guard® Performance Cable Cable for the Most Hostile Environments

    2. Xtra-Guard® Value Proposition Performance and reliability in the toughest environments A large selection that ensures you will find the proper Xtra-Guard cable for your requirements Fewer cable failures and glitches minimizing instances of costly downtime Hazard-matched to survive in the most demanding operating conditions Longest-lasting, highest-performing cable available April 6, 2012 Confidential: Unauthorized Use Prohibited 2

    3. Xtra-Guard® Elements April 6, 2012 Confidential: Unauthorized Use Prohibited 3

    4. Product portfolio Xtra-Guard® Performance Cable April 6, 2012 Confidential: Unauthorized Use Prohibited 4

    5. Xtra-Guard® 1 – High Performance Increased Performance in Critical, High Technology Electronic Signal Applications Unique premium grade PVC insulation and jacket provides for easy routing of cables in tight spaces Fast and easy stripping of insulation and jacket to reduce installation and connectorization time and cost Light-duty resistance to most oils per UL Class 43 Resistance to ambient temperatures up to 105°C Superior performance against EMI / RFI when specified with Supra-Shield®, Alpha’s proprietary, high performance shielding system April 6, 2012 Confidential: Unauthorized Use Prohibited 5

    6. Xtra-Guard® 2 – Abrasion Resistance High Performance in Heavy Duty Industrial Applications such as Abrasion, Cut-Through and Mechanical Abuse, Oils, Chemicals, Solvents, and Fuels Specially formulated, rugged polyurethane jacket has three times the tear and abrasion resistance of ordinary PVC Firm resistance to cut-through and physical damage Moderate to high resistance to most oils, solvents, chemicals and fuels Outstanding ultraviolet light stability in all jacket colors Superior performance against EMI / RFI when specified with Supra-Shield®, Alpha’s proprietary, high performance shielding system April 6, 2012 Confidential: Unauthorized Use Prohibited 6

    7. Xtra-Guard® 3 – Direct Burial Tailored for Outdoor and Direct Burial Applications Combating the effects of Weathering, Moisture, and UV Aging without the costly use of Conduit Specially formulated ethylene propylene copolymer jacket provides outstanding service life in outdoor and direct burial use Direct Burial in wet earth without the costly use of conduit Five times the water resistance of ordinary PVC cable Outstanding ultraviolet light stability in all jacket colors Superior performance against EMI / RFI when specified with Supra-Shield®, Alpha’s proprietary, high performance shielding system April 6, 2012 Confidential: Unauthorized Use Prohibited 7

    8. Xtra-Guard® 4 – Advanced Performance Superior Performance in Outdoor and Direct Burial Applications Combating the effects of Weathering, Moisture, and UV Aging without the costly use of Conduit Superior cable performance in both high and low temperature applications from cold at -50°c to heat at +125°C Three times the low temperature flexibility of ordinary PVC Outstanding UV light stability MSHA and Pennsylvania Bureau Deep Mine Safety approved for Mine-Wide Monitoring Systems UL Type TC 600 volt and Type PLTC rated Superior performance against EMI / RFI when specified with Supra-Shield®, Alpha’s proprietary, high performance shielding system April 6, 2012 Confidential: Unauthorized Use Prohibited 8

    9. Xtra-Guard® 5 – Maximum Performance Top Performance in Unusually Demanding Environments! Impervious to any known Oil, Solvent, Chemical, or Fuel. Outstanding for High Temperature Applications. FEP Teflon® insulation and jacket for top performance at temperatures from -80°C to 200°C Impervious to most oils, solvents, chemicals, fuels, and acids FDA recognized as food/medical grade (can be sterilized) Suitable for use in Class 1 Clean Rooms 20% - 30% smaller diameter than conventional cables Superior performance against EMI / RFI when specified with Supra-Shield®, Alpha’s proprietary, high performance shielding system April 6, 2012 Confidential: Unauthorized Use Prohibited 9

    10. Xtra-Guard® Flex Xtra-Guard Flex performance cable is designed to deliver exceptional performance and reliability in the most strenuous flexing environments High flex, continuous flex, and high torsion From the Xtra-Guard Flex family of cable: Flexible Control Cable Flexible Torsion Cable Continuous Flex Control Cable Continuous Flex Data Cable April 6, 2012 Confidential: Unauthorized Use Prohibited 10

    11. Xtra-Guard® Flex Common Flexing Applications: April 6, 2012 Confidential: Unauthorized Use Prohibited 11

    12. Xtra-Guard® Flex – Flexible Control Cable Ideal for Single Axis, Light-to-Moderate Duty Flexing Environments up to 1 Million Flex Life Cycles Flexible PVC insulation and jacket with overall cable design for installation in C-track or simple flexing applications up to 1 million flex life cycles Easier routing of cables in tight spaces Outstanding oil, solvent, chemical and fuel resistance Perfectly round geometry helps insure a liquid-tight installation per IP-67 or NEMA-6 Superior performance against EMI / RFI when specified with Supra-Shield®, Alpha’s proprietary, high performance shielding system April 6, 2012 Confidential: Unauthorized Use Prohibited 12

    13. Xtra-Guard® Flex – Flexible Torsion Cable Made for Multi-Axis, Torsional Flexing Applications up to 360° from Neutral Position Flexible Hytrel® insulation and rugged polyurethane jacket for installation in twisting and random robotic flexing applications +/- 360° per meter Outstanding service life in heavy duty, high-speed torsional applications High oil, solvent, chemical and fuel resistance Perfectly round geometry helps insure a liquid-tight installation per IP-67 or NEMA 6 Superior performance against EMI / RFI when specified with Supra-Shield®, Alpha’s proprietary, high performance shielding system April 6, 2012 Confidential: Unauthorized Use Prohibited 13

    14. Xtra-Guard® Flex – Continuous Flex Control Cable High Performance in Single Axis High-to Severe Duty Continuous Rolling and Bending Flexing Environments up to 14 Million Flex Life Cycles Flexible PVC insulation and jacket for extreme flexing applications up to 14 million flex life cycles Outstanding service life in heavy duty, high speed cable track applications Outstanding oil, solvent, chemical, and fuel resistance Perfectly round geometry helps insure a liquid-tight installation per IP-67 or NEMA 6 Superior performance against EMI / RFI when specified with Supra-Shield®, Alpha’s proprietary, high performance shielding system April 6, 2012 Confidential: Unauthorized Use Prohibited 14

    15. Xtra-Guard® Flex – Continuous Flex Data Cable Extreme Performance in Single Axis High Flex Duty, Continuous Rolling or Bending Flexing Environments up to 6 Million Flex Life Cycles Flexible PVC insulation and jacket for installation in high flexing applications up to 6 million flex life cycles Perfectly round geometry helps insure a liquid-tight installation per IP-67 or NEMA 6 Outstanding oil, solvent, chemical, and fuel resistance Superior performance against EMI / RFI when specified with Supra-Shield®, Alpha’s proprietary, high performance shielding system April 6, 2012 Confidential: Unauthorized Use Prohibited 15

    16. Markets & applications Xtra-Guard® Performance Cable April 6, 2012 Confidential: Unauthorized Use Prohibited 16

    17. Current Applications Automotive Industrial Machine tools Marine Medical/biotechnology Military Mining Petrochemical April 6, 2012 Confidential: Unauthorized Use Prohibited 17

    18. High Temperature Markets / Applications Mining Foundries Food & Beverage Molten Material Handling Military Petrochemical Welding Robotics April 6, 2012 Confidential: Unauthorized Use Prohibited 18

    19. Low Temperature Markets / Applications Pipeline Monitoring / Control Communications Stations Food & Beverage Equipment Deployment Flow Monitoring Systems Process Control April 6, 2012 Confidential: Unauthorized Use Prohibited 19

    20. Oils, Chemicals, Solvents, Fuels Markets / Applications CNC Equipment Painting Robots Food Handling Packaging Automated Filling Equip. Pharmaceutical Petro-Chemical April 6, 2012 Confidential: Unauthorized Use Prohibited 20

    21. Abrasion Markets / Applications Medical Mining Heavy Equipment Transportation Robotics Process Control April 6, 2012 Confidential: Unauthorized Use Prohibited 21

    22. Flexing Markets / Applications Robotics Material Handling Motion Control Packaging Automotive Pharmaceutical April 6, 2012 Confidential: Unauthorized Use Prohibited 22

    23. EMI / RFI Noise Markets / Applications Instrumentation Panels Imaging Equipment Base Stations Lighting Controls Switching Stations Process Control Precision Multi-Axis Control April 6, 2012 Confidential: Unauthorized Use Prohibited 23

    24. Ultraviolet Light Markets / Applications Mining Pharmaceutical Water / Waste Water Tank Farm Controls Flow / Valve Controls Heavy Equipment Military April 6, 2012 Confidential: Unauthorized Use Prohibited 24

    25. Direct Burial Markets / Applications Irrigation Systems Communications Systems Water / Waste Water Military Security Systems April 6, 2012 Confidential: Unauthorized Use Prohibited 25

    26. Supra-shield® Xtra-Guard® Performance Cable April 6, 2012 Confidential: Unauthorized Use Prohibited 26

    27. Supra-Shield® EMI Protection Against: Conducted EMI: High/Low Frequency Signals Radiated EMI: Proximity to Inductive Sources – Motors, Contactors, Lighting etc. Induced RFI: Cell, Broadcast, Microwave Communications ESD: Grounding (Low Humidity and Motion Systems) April 6, 2012 Confidential: Unauthorized Use Prohibited 27

    28. Supra-Shield® April 6, 2012 Confidential: Unauthorized Use Prohibited 28

    29. Supra-Shield® on Xtra-Guard® Flex April 6, 2012 Confidential: Unauthorized Use Prohibited 29

    30. Jacket Colors April 6, 2012 Confidential: Unauthorized Use Prohibited 30

    31. Factory support Xtra-Guard® Performance Cable April 6, 2012 Confidential: Unauthorized Use Prohibited 31

    32. Custom Cable Design Center® April 6, 2012 Confidential: Unauthorized Use Prohibited 32

    33. Xtra-Guard® Products vs. Applications For more information on which Xtra-Guard product is right for your application, visit www.AlphaWire.com and click on Xtra-Guard® Performance Cable under the Products tab. April 6, 2012 Confidential: Unauthorized Use Prohibited 33

    34. Marketing Support April 6, 2012 Confidential: Unauthorized Use Prohibited 34

    35. Alpha Wire Product Family April 6, 2012 Confidential: Unauthorized Use Prohibited 35

More Related