1 / 37

Westinghouse Nuclear Engineering Headquarters

Westinghouse electric nuclear engineering headquarters Daniel Aughenbaugh - Mechanical option. Westinghouse Nuclear Engineering Headquarters. Daniel Aughenbaugh Mechanical Option.

Download Presentation

Westinghouse Nuclear Engineering Headquarters

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Westinghouse electric nuclear engineering headquartersDaniel Aughenbaugh - Mechanical option Westinghouse Nuclear Engineering Headquarters Daniel Aughenbaugh Mechanical Option

  2. Presentation OutlineIntroductionExisting mechanical systemMy Design analysesdedicated outdoor air systemground source heat pump plantcentral plantplant initial costplant lifecycle costarchitectural study- façade redesignconclusions Westinghouse Nuclear Engineering Headquarters Daniel Aughenbaugh Mechanical Option

  3. facility informationlocation: Pittsburgh areaProject cost: $240 millionComplex size: 3 buildings (4-5 loors) 844,600 SFOccupancy type: open officedelivery method: Design-bid-build joint ventureconstruction period: 2/2008 - 5/2010 Westinghouse Nuclear Engineering Headquarters Introduction

  4. Westinghouse Nuclear Engineering Headquarters Introduction

  5. Westinghouse Nuclear Engineering Headquarters Introduction

  6. Program is largely open office space with a Cafeteria, Data Center, and Fitness Center Façade is approximately 40% glazing for all orientations VAV system conditions the Office Spaces CRAC Units condition the Data Center Four Air Handling Units supply 293,600 CFM and 40% OA Three 450 Ton Chillers and Cooling Towers Electric Resistance Re-heat Facility Mechanical Information Westinghouse Nuclear Engineering Headquarters Current Design

  7. Redesign Analyses Westinghouse Nuclear Engineering Headquarters Redesign Analyses

  8. Reduce Plant Loads with a Dedicated Outdoor Air System • Investigate a Hybrid Ground Source Heat Pump Plant • 3. Investigate a Central Plant Redesign Analyses Westinghouse Nuclear Engineering Headquarters Redesign Analyses

  9. Energy Use • Initial Cost • Lifecycle Cost • Indoor Air Quality • Environmental Impact • Construction Impact • Operation and Maintenance Redesign Analyses Westinghouse Nuclear Engineering Headquarters Redesign Analyses

  10. Dedicated Outdoor Air System Westinghouse Nuclear Engineering Headquarters DOAS

  11. 1. Less Ventilation Air 2. Indoor Air Quality 3. Sensible and Latent Loads are decoupled Dedicated Outdoor Air System Westinghouse Nuclear Engineering Headquarters DOAS

  12. Proposed: • Active Chilled Beams (ACB) • DOAS Fan Powered Terminal Units (FPT) • 3. ACBs to condition Core Office Areas, DOAS FPTs to condition Perimeter Office Areas Plant Load Reduction Westinghouse Nuclear Engineering Headquarters DOAS

  13. Active Chilled Beams Westinghouse Nuclear Engineering Headquarters DOAS

  14. DOAS Fan Powered Terminal Units Westinghouse Nuclear Engineering Headquarters DOAS

  15. Plant Loading Westinghouse Nuclear Engineering Headquarters DOAS

  16. System Initial Cost Westinghouse Nuclear Engineering Headquarters DOAS

  17. System Life Cycle Cost Westinghouse Nuclear Engineering Headquarters DOAS

  18. Hybrid Ground Source Heat Pump Plant Westinghouse Nuclear Engineering Headquarters Hybrid GSHP

  19. Hybrid GSHP Plant Schematic Westinghouse Nuclear Engineering Headquarters Hybrid GSHP

  20. Hybrid GSHP Sizing Cooling Tower Size Ground Loop Size Westinghouse Nuclear Engineering Headquarters Hybrid GSHP

  21. Plant Initial Cost Westinghouse Nuclear Engineering Headquarters Plant Analysis

  22. Plant Lifecycle Cost Westinghouse Nuclear Engineering Headquarters Plant Analysis

  23. Architectural Study- Façade Redesign Westinghouse Nuclear Engineering Headquarters Architecture

  24. North View South View Westinghouse Nuclear Engineering Headquarters Architecture

  25. South Façade Redesign Westinghouse Nuclear Engineering Headquarters Architecture

  26. South Office Section Westinghouse Nuclear Engineering Headquarters Architecture

  27. North Office Redesign Westinghouse Nuclear Engineering Headquarters Architecture

  28. North Conference Redesign Westinghouse Nuclear Engineering Headquarters Architecture

  29. North Façade Redesign Westinghouse Nuclear Engineering Headquarters Architecture

  30. Buffer Zone Redesign Westinghouse Nuclear Engineering Headquarters Architecture

  31. Plant Impact Westinghouse Nuclear Engineering Headquarters Architecture

  32. Conclusions Westinghouse Nuclear Engineering Headquarters Conclusions

  33. Conclusions: Air Systems Westinghouse Nuclear Engineering Headquarters Conclusions

  34. Conclusions: Mechanical Plant Westinghouse Nuclear Engineering Headquarters Conclusions

  35. Conclusions The best alternate Air System for the Westinghouse Headquarters is a Dedicated Outdoor Air System coupled with an all DOAS Fan Powered Terminal configuration to condition the office space. The best alternate Plant for the Westinghouse Headquarters is a Hybrid Ground Source Heat Pump Plant. Westinghouse Nuclear Engineering Headquarters Conclusions

  36. Thank You... Professor Bahnfleth Professor Freihaut Professor Holland Bob Hennessey, Turner Construction Ernie Tillman, LLI Engineering Joel R. Bernard, IKM Inc. Special Thanks to all my friends and family for their support! Westinghouse Nuclear Engineering Headquarters Conclusions

  37. Questions ? Westinghouse Nuclear Engineering Headquarters Daniel Aughenbaugh Mechanical Option

More Related