270 likes | 420 Views
Topics in Magnetic Resonance Angiography Research and Some Potential New Directions. Dennis L. Parker et al. Goal – Increase Vessel Signal. Acquisition Techniques RF coils, Pulse sequences, Field strength Post Processing Vessel enhancement, noise reduction techniques Vessel Segmentation
E N D
Topics in Magnetic Resonance Angiography Researchand Some Potential New Directions Dennis L. Parker et al.
Goal – Increase Vessel Signal • Acquisition Techniques • RF coils, Pulse sequences, Field strength • Post Processing • Vessel enhancement, noise reduction techniques • Vessel Segmentation • Aneurysm Screening • New contrast agents
Outline • Acquisition Techniques • RF coils, Pulse sequences, Field strength • Post Processing • Vessel enhancement, noise reduction techniques • Vessel Segmentation • Aneurysm Screening • New contrast agents
MRA - TOF : Time-Of-Flight Blood Flow Signal Partially Saturated Spins v1 >v2 >v3 Saturated Static Tissue v1 v2 v3 tn = THK / vn (n=1,2,3) TR Slab THK t1 t2 t3 Fresh Inflow d=v TR Static Tissue Signal vessel v TR blood flow TR : Repetition time
Acquisition Techniques • RF Coils • Reduce electric coupling, reduce noise figure • Pulse Sequences • Variable echo time • Double echo 3D TOF • Segment blood from tissue • Post processing noise reduction • 3D PR for ultrashort echo time (TE) • Novel Black-Blood sequences for carotid artery
MRI Projects:3D TOF Complete FC + Variable Echo Time (VTE) • Eun Kee Jeong Non-VTE with Complete FC VTE with Complete FC
Efficient Double Inversion FSE • DL Parker, EK Jeong, SE Kim, Eugene Kholmovski
MRI Projects: Carotid Imaging Free Slices • Triple Double FSE: Interleaved Double Inversion Double Echo Non-interleaved acquisition. Interleaved acquisition.
MRI Research: Carotid Imaging • Triple Double FSE: Interleaved Double Inversion Double Echo • Eugene: Triple Contrast: Interleaved Double Inversion Double Echo with interleaved T1
Outline • Acquisition Techniques • RF coils, Pulse sequences, Field strength • Post Processing • Vessel enhancement, noise reduction techniques • Vessel Segmentation • Aneurysm Screening • New contrast agents
Post ProcessingBrian Chapman • Noise Reduction • Vessel Enhancement Filtering
Post ProcessingEugene Kholmovski • Noise Reduction • Image Redundancy
Original PD Original T2 Corrected PD Corrected T2 Spectral energy (non-image support) Double Echo FSE Motion Artifact Reduction • Eugene Kholmovski
Standard Image POCS SENSE Reduction = 2, Ncoils = 4 Eugene Kholmovski
Standard SENSE POCS SENSE Reduction = 4, Ncoils = 4 Eugene Kholmovski
Outline • Acquisition Techniques • RF coils, Pulse sequences, Field strength • Post Processing • Vessel enhancement, noise reduction techniques • Vessel Segmentation • Aneurysm Screening • New contrast agents
Conventional MIP Depth (Z-)Buffer Image Z-Buffer Segmentation (ZBS) Algorithm
Future Segmentation • Incorporate Additional Information • Directionality • Signal intensity continuity • Segment the segmentation • Centerline recognition • Label vessel segments • Shape descriptors (tortuosity) • Use sparse vessel locations to speedup 3D PC and 2D PC techniques.
Outline • Acquisition Techniques • RF coils, Pulse sequences, Field strength • Post Processing • Vessel enhancement, noise reduction techniques • Vessel Segmentation • Aneurysm Screening • New contrast agents
High Resolution MRA Applications to Aneurysm Screening 3 Aneurysms, without (left) and with (right) Gadolinium Contrast. Parker, Tsuruda, et al., University of Utah
MRA Aneurysm Screening Results • Screening of high risk families • 143 high-risk intracranial aneurysm pedigrees found • 3400 total members • 340 relatives screened with MRA (29 aneurysms detected) • Evidence for a gene detected Dennis L. Parker, University of Utah
Outline • Acquisition Techniques • RF coils, Pulse sequences, Field strength • Post Processing • Vessel enhancement, noise reduction techniques • Vessel Segmentation • Aneurysm Screening • New contrast agents
General Focus • Goal to increase visibility of vascular disease • Aneurysms, embolic disease, atherosclerosis • Improve efficiency in MRA • Increase signal, post processing for noise reduction. • Use MRA for longitudinal studies of disease • Aneurysm Screening, carotid disease • New contrast agents • Blood pool, targeted agents
Signal Regrowth Mz T1 (slow ~ 1s) Blood T2 should appear Longer than tissue T2 Mx My T2 (fast ~ 100ms)