Database in Analysis. Kanglin He 17 June, 2007. Outline. General run status database From DAQ, slow control and offline group Luminosity & beam parameters From tools group Data correction related coefficients From tools and Physics groups, rec V related
E N D
Database in Analysis Kanglin He 17 June, 2007
Outline • General run status database • From DAQ, slow control and offline group • Luminosity & beam parameters • From tools group • Data correction related coefficients • From tools and Physics groups, rec V related • Data Quality Assurance (DQA) database • From Validation group, rec V related • Physics Quality Assurance (PQA) database • From Physics groups, rec V related
Run type Cosmic/collision J/psi, Psi’, R, tau, etc Detector status Status: good/usable/bad Reason: HV trap, gas unusual, noise, etc,… Electronics status Status: good/usable/bad Reason: dead channel, noise, etc, Calibration status Status: good/usable/bad Reason: T0 problem, resolution too bad, etc Run status Status: good/usable/bad Reason: detector/ electronic/ calibration General run status
Offline luminosity Bhabha Dimu Diphoton Average luminosity Errors Statistic Systematic ? Beam energy Beam energy Beam energy spread Beam position X, Y, Z Errors of X, Y, Z Luminosity & beam parameter
Data correction coefficients • Second calibration of each detector • MDC, dE/dx • TOF, offset correction, t0 correction • EMC, photon energy correction • MUC, noise and efficiency • More corrections from tools/physics groups
DQA database • General data qualities check • Status and related Histogram • Key distributions for each detector • Common systematic uncertainties table • Tracking: • Particle species • Dimensioned by momentum and polar angle • Neutrals • PID
PQA distribution • Key variables monitoring • Invariant mass, angular distribution, etc • Histogram • Special physics tags monitoring • Tag numbers, key variable histograms • Fine correction coefficients for data and beam energy • Systematic error tables for common analysis topic
各系统数据字典汇总 • 在线 • 慢控制 • 离线
慢控制 • MDC探测器温湿度42路 • 探测器外围环境温湿度 • MDC探测器高压状态 • MDC探测器高压值 • MDC探测器高压值 • MDC高压插件温度 • EMC桶部温度 • EMC桶部温度60槽×8=480路 • EMC桶部温湿度 • 桶部每槽东西两端各一个温湿度传感器,60槽*2(东西)*2(温湿)=240
慢控制(Cont.) • EMC端盖温度120路(未安装) • EMC端盖温湿度40路(未安装) • TOF温度40路(测试中) • TOF高压452路,插件温度40路(未安装) • Muon桶部温度 • Muon桶部共16条电缆,每条电缆8个传感器,16*8=128路 • Muon桶部温湿度32路 • Muon端盖温湿度128路
慢控制(Cont.) • Muon高压144路,插件温度12路(未安装) • EMC NIM机箱温度600路(未安装) • EMC NIM机箱电压240路(未安装) • Muon低压电源电压电流88路(未安装) • Muon低压电源温度44路(未安装) • TOF低压电源电压电流24路(未安装) • TOF低压电源温度8路(未安装) • MDC VME机箱监控304路 • EMC VME机箱监控304路(未安装) • TOF, Muon, Trigger VME机箱监控共9台(未安装)
慢控制(Cont.) • Online PC farm温度70路 • 探测器环境温度100路 • 电缆槽温度100路 • 电子学环境温湿度20路 • BESIII房间温湿度32路 • 16(BES大厅)、4(Online room),8(Control room)、4(Trigger room) • 气体系统(未安装) • 安全联锁系统(未安装)
Run_Number int(11) Run号 Muon_Temp decimal(6,2) Muon探测器的温度 Tof_Temp decimal(6,2) Tof探测器的温度 Emc_Temp decimal(6,2) Emc探测器的温度 Mdc_Temp decimal(6,2) Mdc探测器的温度 表名:SC-Offline 表名:OnLine-OffLine