300 likes | 388 Views
Adhesives for Electronics. Reliability Study of Sub 100 Micron Pitch, Flex-to-ITO/glass Interconnection, Bonded with an Anisotropic Conductive Film. Cameron T. Murray, Peter B. Hogerton, Theary Chheang, Robert L. Rudman 3M Company Bonding Systems Division, 230-2E-11, St. Paul, MN 55144.
E N D
Adhesives for Electronics Reliability Study of Sub 100 Micron Pitch, Flex-to-ITO/glass Interconnection, Bonded with an Anisotropic Conductive Film. Cameron T. Murray, Peter B. Hogerton, Theary Chheang, Robert L. Rudman 3M Company Bonding Systems Division, 230-2E-11, St. Paul, MN 55144 3M Bonding Systems Division
Z-Axis/ Anisotropic Conductivity Conductivity in the Z direction only (through the thickness of the adhesive) Z 3M Bonding Systems Division
Flex to ITO Bonding Flex Circuit LCD Copper trace ITO Trace ZAF Glass Polymer particle preferred with ITO traces 3M Bonding Systems Division
Cellular Phone Applications for ZAF • Flex to ITO glass • 5000 series - specific product depending upon pitch • Flex to PCB • 7303 or 5000 series depending upon pitch 3M Bonding Systems Division
Making Reliable Bonds • Proper thermocompression bonding technique • Flex alignment to ITO/glass or PCB • Proper thermal cure profile • Proper pressure • Proper overlap area • guaranteed minimum number of particles (to provide low electrical resistance) • Proper pitch • minimum space between traces to avoid shorting 3M Bonding Systems Division
Thermocompression Bonding Applied pressure Compliant layer Bonding Thermode Flex Circuit ITO Glass Z-Axis Conductive Film 3M Bonding Systems Division
Pressure Uniformity 3M Bonding Systems Division
Temperature Profile Ram pressure Compliant layer Bonding Thermode Flex Circuit ITO Glass Thermocouple 3M Bonding Systems Division
Overlap Area Flex Circuit LCD Copper trace ITO Trace ZAF Glass Overlap Area = ZAF width x Trace width 3M Bonding Systems Division
Overlap Area 3M Bonding Systems Division
Particle Count 3M Bonding Systems Division
Reliability Study • Fine Pitch Flex bonded to ITO/Glass (10 W /square) • 80, 100 micron pitch • 285 interconnections per condition • Peel Testing and Electrical Resistance • Environmental Testing Conditions • 100 °C for 1024 hours • 125 °C for 1025 hours • 60 °C / 95 % RH for 1029 hours • -40 °C to 100 ° C Thermal cycle (1 hour/cycle) for 1029 cycles • -55 ° C to 125 °C for 1820 cycles - Thermal shock • 85 °C and 85 % RH for 1028 hours 3M Bonding Systems Division
Thermocompression Bonder Thermode Compliant layer Circuitry 3M Bonding Systems Division
Temperature Profile 3M Bonding Systems Division
LCD Visual Inspection 3M Bonding Systems Division
Proper Bond Formation 3M Bonding Systems Division
Particle Compression - Top 3M Bonding Systems Division
Particle Compression - Side 3M Bonding Systems Division
4 Wire Resistance Test • Test designed to subtract out the resistance of the copper traces and the ITO glass: • Requires specialized flexible circuit design • Automated testing jig/ computer data collection • 57 measurements per sample / 5 samples per condition • Microvoltmeter and power supply • Test limitations • Perfect circuit design not possible - measured resistance is influenced by ITO resistance • Samples must be removed from the environment for testing 3M Bonding Systems Division
4 Wire Test Circuit Test Pads Circuit Traces 3M Bonding Systems Division
4 Wire Test Pads Power Supply Voltmeter 3M Bonding Systems Division
100 Micron Reliability 3M Bonding Systems Division
80 Micron Reliability 3M Bonding Systems Division
Peel Test • IPC TM-650 2.4.9.1 • 2.5 mm / min peel rate • 90 degree angle • Reported values = maximum value on plot • Peel testing performed at the conclusion of environmental aging • 5 peeled parts per environmental condition 3M Bonding Systems Division
Typical Peel Test 2.5 mm/min 3M Bonding Systems Division
Peel Reliability 3M Bonding Systems Division
Shorting Test • Flex with 30 micron gap bonded to non-conductive glass • Initially shorts found - related to fillet formation over edge of ITO glass • 128 flex samples remade with proper bonding • 12,800 gaps measured with no shorts 3M Bonding Systems Division
Conclusions • Fine pitch circuitry can be bonded with Z-Axis Films into a highly reliable interconnection • Proper bonding conditions and equipment are important when making a reliable bond • proper placement of ZAF to prevent shorting • proper particle compression • proper thermal profile for good mechanical (peel) performance • Visual inspection combined with electrical and peel testing are important tools in monitoring process control 3M Bonding Systems Division