An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Mesopic vision model and its application János Schanda Virtual Environments and Imaging Technologies Laboratory University of Pannonia

  2. Overview • Mesopic vision fundamentals • The five photosensitive cells in the human retina • Luminance type and brightness type description • The CIE TC 1-69 mesopic model • Examples of application

  3. Luminance levels

  4. Mesopic vision • Classical interpretation • Daylight: photopic – cones • Dark adaptation: scotopic – rods • Twilight vision: mesopic – cones + rods • Present day knowledge • Foveal vision: photopic • Pupil diameter: intrinsically photosensitive Retinal Ganglion Cells (ipRGC)? • Difference between perception and detection

  5. Spectral responsivity of light sensitive cells in the human retina 3 types of cones, rodsand ipRGCs (Cirk.-Gall) 5

  6. Perception and detection • Perception: • seeing details, perceiving brightness • all 3 cone types & rods • + ipRGC (?) • slower • Detection: • only L & M cones + rodsluminance like signal • fast

  7. Colour perception

  8. Historic overview The two stumbling blocks of mesopic photometry: Purkinje shift rod and cone interaction transition from cone to rod sp.resp. differs from Purkinje shift Helmhotz-Kohlrausch effect difference between luminance and brightness

  9. Early investigations • Fovea: only cones • Luminance like: rapid, contrast • Brightness + colour: slower mechanism • Peripheric vision: rods + cones • In mesopic the influence of rods increases

  10. Early investigations • Brightness description: • Kokoschka 3 conew + rods • Sagawa brightness model • Contrast threshold investigations Non-linear! • Reaction time based models • aV(l)+(1-a)V’(l)

  11. Spectral responsivity at different luminance levels Walters & Wright : Proc. Roy. Soc. 1943. At low mesopic levels first a shoulder is found at longer wavelength At mid-mesopic a transition from rod to cone takes place: broadening of curve At high mesopic narrowing to V(l) is found

  12. Spectral responsivity at different luminance levels Kinney clearly identifies in 1955 that at high mesopic and photopic levels brightness sensitivity has a multi bump nature

  13. CIE 1963 mesopic spectral sensitivities

  14. Brightness perception • Observation • Coloured lights brighter that white (or yellow) • Influence of • S cones • Rods, even in daylight • ipRGC, responsible also for the circadian rhythm

  15. Quantitative descriptions of mesopic luminance Equivalent luminance (CIE 1963):„The equivalent luminance of the field of an arbitrary spectral composition is the standard luminance of another field which has the colour temperature of 2042 K and which in particular photometric conditions seems to be equally bright to the first field.”

  16. Mesopic 2 function brightness scale • Palmer (1966, 1967, 1968): Equivalent luminance (L) for large fields L(S,P)=(MS+P 2)/(M+P) where: • S: scotopic value • P: photopic (10°) value • M parameter, 6.28 . 10-2 cd/m2for 15°field • Other models used direct cone brightness functions (e.g. Ikeda & Shimozono, 1981; Nakano & Ikeda, 1986; Sagawa & Takeichi, 1983; modified Palmer formula)

  17. Mesopic 4 function brightness • Helmhotz-Kohlrausch effect: brightness non-additivity, influence of all three cone types • Kokoschka model • Trezona – Clarke model • Problem of transition between luminance type (photopic) and brightness type (scotopic) experimental data: Viénot et al.

  18. Kokoschka model where Fx, Fy, Fz functions depend on luminance level, L10 is photopic 10°luminance S is scotopic luminance X10, Y10, Z10 are 10° tristimulus values

  19. Mesopic models • Lighting Research Center of North America system: with 0,001 cd/m2 < Lmes < 0,6 cd/m2 • MOVE model, based on • Ability to detect target • Speed of detection • Ability to identify details of target with soft transition to scotopic and photopic at • 0,01 cd/m2 < Lmes < 10 cd/m2

  20. Kokoschka model functions and derived spectral luminous efficiency functions

  21. Brightness/luminance discrepancy & rod/cone interaction + ipRGCs • In photopic regime one assumes: • luminance to be a combination of the L- and M-cone signals • Brightness to be a combination of all three cone signals after a transformation into magno-, parvo- and conio-cellular signals • In mesopic regime rod contribution has to be added. • Recently found ipRGCs have influence on pupillary reflex, influencing light reaching the retina

  22. Photopic regime: brightness/luminance Magnocellular pathway: luminance like Brightness: all 3 channels B=(L2+d2+t2)1/2 (Guth model) Influence of ipRGCs?Different brightness of metameric samples

  23. Mesopic: rod contribution • Two pathways for rod-cone interaction • Classical: via rod bipolar (RB) and amacrine (RA) cells to cone bipolars (DCB & HCB) • Direct pathway via gap junctions From Buck SL: Rod-cone interaction in human vision, The visual neuroscience

  24. 2 new CIE reports CIE supplementary system of photometry, CIE 200:2011 Recommended system for mesopic photometry based on visual performance, based on MOVE and X-models

  25. Detection • Traffic situation • Detecting the presence of an obstacle • Rapid action necessary • Can be approximated by and additive system • Abney’s law holds photometry possible • Should have smooth transition to photopic and scotopic at the two ends.

  26. Comparing the two systems Two lamps with S/P ratio: 0.65 and 1.65: difference of mesopic lum to photopic lum. in the two systems

  27. CIE TC 1-58 system, 1 • Compromise solution between the two experimental systems, main input data: • achromatic contrast • reaction time (see ball in windshield of virtual reality simulation)

  28. CIE TC 1-58 system, 2 • The system is not for visual performance : • if chromatic channel signals are important:S/P ratio very higy or low • if target has narrow band spectral power distributions • if brightness evaluation is required • Mesopic limits:0,005 cd/m2 < Lmes < 5 cd/m2 • The TC 1-58 system is for adaptation luminance, i.e. background luminance, not for calculating mesopic luminance of target • Foveal vision is photopic!

  29. Calculating mesopic luminance, 1 Photopic luminance Scotopic luminance Mesopic luminance: where and Vmes(l0)=Vmes(555nm) m =1 if Lmes>5.0 cd/m2 m =0 if Lmes<0.005 cd/m2 M(m) is a normalizing constant: Vmes,max=1

  30. Calculating mesopic luminance, 2 • m is calculated using iteration • Start with m0=0.5 • Calculate Lmes,n from Lmes, n-1: where

  31. Vmes at different m values

  32. Calculation from pavement illuminance • Input data: • Photopic luminance: Lp • Luminance coefficient of road surface (q=L/E) • S/P ratio of light source, where and S(l) is the rel.sp. power distribution (SPD) of the lamp to be used

  33. Calculation from pavement illuminance • Calculate Lp=qE • Calculate S/P and with Lp determine Ls • Calculate Lmes,1 fromwith m0=0.5 • And do the iteration, usually 5 to 10 iterations are needed to get final Lmes • If Vmes is required, used

  34. Some examples • q= 0.0016 and • q= 0.032 • Typical light source S/P values:

  35. Numeric evaluation

  36. Visual acuity and lamp spectrum • Transmission of eye media changes with age • Test with cool-white and warm-white LEDs • Young observers: < 30 years of age • Old observers: > 65 years of age • Reading Snellen table at 0.1 cd/m2 and 1 cd/m2

  37. Visual acuity and lamp spectrum, results • Young observers have less errors at 0,1 cd/m2 under CW-LED • At 1 cd/m2 the difference is not significant

  38. Summary • The mesopic photometry model is valid for background adaptation luminance • It refers to reaction time type of tasks, not brightness • For foveal vision V(l) based metric (photopic photometry) is valid! • It is an experimental model for trial, has to be validated with real street lighting tests and accident simulations • In preparing new recommendations spectral vision differences between young and old observers should be considered

  39. Peter Kaisers vision of the future photometer in 1981 • Modern image taking photometers are almost there • + info: • background • ipRGCs