Computer Room Efficiency Improvement

Computer Room Efficiency Improvement. Greening ICT project with JISC 23 rd of September 2011. Objectives. Reduce power consumption in Computer Rooms by 5% a year using a combination of measures: Air-to-air cooling units (“free” cooling)– more efficient room cooling

rossa
Download Presentation

Computer Room Efficiency Improvement

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Computer Room Efficiency Improvement Greening ICT project with JISC 23rdof September 2011

  2. Objectives • Reduce power consumption in Computer Rooms by 5% a year using a combination of measures: • Air-to-air cooling units (“free” cooling)– more efficient room cooling • Cold aisles inside the rooms – more efficient equipment /racks cooling • Windows films/replacement, UPS downsizing, efficient lighting – reduce heat generation • Miscellaneous – adjustments to cooling units • Share experience with educational sector and offer a project role to Imperial students. • www.imperial.ic.ac.uk/blog/griphttp://www.jisc.ac.uk/whatwedo/programmes/greeningict.aspx • Follow best practices outlined in EU Code of Conduct for data centres. In cooperation with

  3. Latest status • Awaiting quotes for free cooling, cold aisles and lighting equipment and installation. • Finalizing Data centre electricity meter readings reporting:emotr.absconsulting.uk.com • Ready to submit participant application to EU Code of Conduct board. • Working on improving temperature reporting and control in the computer rooms. • Project team: Tom Billing, ABS Consulting • Kevin Cope, EstatesShiang Chin, 4th Year Mechanical Engineering student • Brian D’Lasselle, Estates • Steven Lawlor, ICT Computer Rooms • Archie Spence, ABS ConsultingAlex Yakimov, ICT Technical Operations

  4. EMOTR software 

  5. Chilled water units

  6. Background • Our Computer rooms (Data Centres) host around 2,500 servers and support; Imperial College, Natural History Museum, Royal College of Music and Janet-LMN • This project focuses on our primary Data Centre (two main rooms), housed in a traditional 1960’s building. Room 401 PUE = 1.32, Room 402 PUE = 1.52 • Annual consumption is circa: 7,500,000 kWh £500,000 4,000 tCO2 • Target 5% reduction in annual energy consumption Free Air Cooling Option:Supplement Existing Chilled Water More efficient lighting Extend Cold Aisle containment (further 56 racks)