Dry Air System and Drawing Current. Motivation . The study is made to correlate the MuTr drawing current and humidity. After installation of cramps to Station-3, the dry air system is now fully implemented in Station-2 and Station-3 in both arms. Station-1 doesn’t have dry air system.

rowdy
Download Presentation

Dry Air System and Drawing Current

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Dry Air System and Drawing Current

  2. Motivation • The study is made to correlate the MuTr drawing current and humidity. • After installation of cramps to Station-3, the dry air system is now fully implemented in Station-2 and Station-3 in both arms. Station-1 doesn’t have dry air system. • If station-1 suffered from dark current under high humidity and station-2&3 don’t, then it proves the power of the dry air system.

  3. Station-3 and Dry Air System

  4. MuTr Disabled HV Channel History ( ) are station-3

  5. IR Humidity From Feb.1 – Jun.10,2013 ~ 40% ~ 12%

  6. Run13 Dry Air Configuration See if Station-1 dark current increases as humidity gets higher. The currents were sampled from cosmic data taking in order to be free from drawing current induced by beam luminosity.

  7. South Station-1 Octant(1-4) Plot by Sanghwa

  8. South Station-1 Octant(4-8)

  9. South Station-2

  10. South Station-3

  11. North Station-1 Octant1-4

  12. North Station-1 Octant5-8

  13. North Station-2

  14. North Station-3

  15. Observation Summary • Although the humidity fluctuate in daily basis, overall increase of IR humidity from 10 to 40% are observed from beginning of Run13 towards the end of Run. • The obvious increase in drawing current in station-1 have not been observed within the range of the humidity change. • The correlation with IR humidity and drawing current in Station-2 and 3 were not seen neither.

  16. Conclusion • The humidity of 40% may not be high enough to draw the additional current on MuTr. • Cannot think of any other way to evaluate the effect of dry air system now.