1 / 25

IO-Link Safety: Digitalization down to the smallest functional safe Sensors/Actuators/Mechatronics

Explore the requirements of customers and manufacturers and discover the benefits and achievements of IO-Link Safety. Learn about the future developments and the potential of IO-Link Safety in the field of automation.

ryanp
Download Presentation

IO-Link Safety: Digitalization down to the smallest functional safe Sensors/Actuators/Mechatronics

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. IO-Link SafetyDigitalization down to smallest functional safe Sensors/Actuators/Mechatronics Event…Author…

  2. Overview • Requirements of Customers and Manufacturers • WhatisOSSDe all about? • Whya newsafecommunicationprofile? • Whatdidweachieve so far? • What'snext? IO-Link Safety Status

  3. Manufacturer's Situation Safetycontroller(FS-PLC) FS-PLC Fieldbus / FSCP Remote I/O with FS modules FS-DI Redundant signallines FS = functionalsafety PLC = programmablelogiccontroller e.g. Emergency Stop IO-Link Safety Status

  4. Customer's Situation • Machinemanufacturerdecides on fieldbustobeuseddepending on deploymentcase • Thus, specificdevicesforeachfieldbuswith separate sparesinventory, versionmaintenanceandservicearerequired • Thus, high degreeofpersistencetostaywith "classic" interfaces such as OSSD, 4 to 20 mA, and etc. on "remote IO" fielddevices, sincetheyareindependentfromfieldbus • However: noconnectionto Internet-of-Things (IoT) andIndustry 4.0 • Numerousnewapplications: (see "Smart Manufacturing")- New sensortechnologies, e.g. strain, torque, pressure, multi-sensing, and etc.- More measuringsensors, e.g. objecttypes, distance- Mechatronics, e.g. combinationssensors/actuators • Progressive miniaturization IO-Link Safety Status

  5. IO-Link Safetyas a Solution Fieldbuswithoneofthe FSCPs (IEC 61784-3) Remote I/O FS-Master AI AO DI DO 0 0 0 0 0 0 0 7 7 7 7 7 7 7 e.g. 0 to 10 V IO-Link Safety OSSD PM switching Analog measure- ments Digitized measure- ments Switches OSSDe or COM Relays Intelligent drives IO-Link Safety Status

  6. Automation "hierarchy" with IO-Link Safety PLC Level Higher-Level Systems (FunctionalSafety) safety safety Fieldbus Level Enabling New Markets with IO-Link FS-Master (mappingand/orlocalprocessing) SIOMode OSSDeMode Sensor / Actuator / IO-Link Devices Mechatronic Level a Worldwide Standard with IO-Link Safety Devices FS-Devices Valves | Locking Units | Light Curtains IO-Link Safety Status

  7. WhatisOSSDe all about? IO-Link Safety Status

  8. Redundant Signals (OSSD) OFF state IOL-OSSDe IOL-OSSDe: Equivalentsignals Testpulses L+ OFF state IOL-OSSDe 1 C/Q 2 4 3 4,8 / 38,4 / 230,4 kbit/s I/Q COMx IO-Link Safetycommunication L- AIDA compatible! OSSD: Output SwitchingSensing Devices (Solid stateoutputs) OSSDe: = OSSD withequivalentswitchingsignals; type C, class 1 accordingto Position Paper CB24I (ZVEI) IO-Link Safety Status

  9. Migration Strategy (example: PROFIsafe) PROFIsafe1999 FS-Master Remote IO F-Device Fieldbus(FSCP) Remote IO F-DI F-DI FS-Master andothers… IEC 61784-3-3 Develop… Connect…(Subset) Connect… Connect… Develop… IO-Link Safety2018 IO Level("OSSD") F-Sensor FS-Device ZVEICB24I OSSD New: OSSD + communication IO-Link Safety Status

  10. "Off-Site" Parameterizationand Test (OSSDe) Off-site configuration & parameterization Fieldbus F-DI Modul FS-Master "USB Master"Tool software withsafety 0 0 0 0 IODD Remote IO USB 7 7 7 7 OSSDe "USB-Master" Parameter Test FS-Device FS-Device History IO-Link Safety Status

  11. IO-Link Safety Communication IO-Link Safety Status

  12. FunctionalSafety Communication Profiles (FSCP) FSCP 3 FSCP 12 FSCP 6 FSCP 1 FSCP 2 FSCP 14 FSCP 18 FSCP 13 Non-IEC"A" FSCP 17 Non-IEC "C" FSCP 8 IEC 61784-3-x:Collection of FSCPs IO-Link Safety Status

  13. Specificationsand Assessment Reports IO-Link Safety Status

  14. "Black Channel" Principle also with IO-Link Safety Safetyapplication Standard application, e.g. Diagnosis Standard application, e.g. Diagnosis Safetyapplication FSCP(e.g. PROFIsafe) Gateway SafetyCommunication Layer (SCL) IO-Link Safety IO-Link Safety Device(Stack) Master(Stack) IO-Link("Black Channel") Point-to-point communication IO-Link Safety Status

  15. Messages with IO-Link Safety From FS-Master: Non-safetyProcessDataOut CRC Signature Control & M-Counter Portnumber Safety ProcessDataOut 32 to 0 octets 2/4 octets 1 octet 1 octet 3/25 octets From FS-Device: Safety Process Data In PortNumber Status & D-Counter CRC Signature Non-safety Process Data In 3/25 octets 1 octet 1 octet 2/4 octets 32 to 0 octets IO-Link Safety Status

  16. Start-up andSecuringMeasures Communication, Identification Wake-up Ready Selftest Mastercommand SIO / OSSDe PowerOffOn PowerOffOn Cyclic Process Data exchange Configure, Parameterize Mastercommand • Safetyparameterverification (VerifyRecord) • Misconnection? (Authenticity/Port check) • Replacement? (Data Storage if "out-of-the-box") Parameter verified?  Start safetycommunication (SCL) IO-Link Safety Status

  17. Test andAssessment IO-Link Safety Status

  18. Automatic Test Case Generation Test scripts Sequencecharts IO-Link Tester IO-Link Safety Status

  19. FS-Master Tester (withoutfieldbusdependency) Fieldbus layers / Ethernet FSCP Gateway IO-Link/PROFINET FSCP Test FS mapping Temporarytestsignalchannel(partofthesafetyimplementation) IO-Link Safety FS-Master Standardized Master Interface (SMI) ConfigurationManager CyclicProcessData Exchange Splitter/Composer (Parameter)Data Storage AcyclicDataExchange DiagnosisUnit IO-Link safety Test Master layers Test signaldata SPDU FS-Master Tester IO-Link Safety Status

  20. Integration example: PROFINET / PROFIsafe White Paper PROFINET Integration IO-Link Safety Status

  21. System Overview (PROFINET / IO-Link) • Engineering System • IO controller • IO supervisor PROFINET domain • PNIO • PROFINET/PROFIsafe • IO device • GSD(IO device) • Linking Module (B)"safety" • FS-Master • IO-Link PDCT • IO-Link • IO-Link • Port 1 • Port 4 • Port 2 • Port 3 • IODD(Device,FS-Device) • IO-Link domain Off-site commissioning • FS-Devices/Devices IO-Link Safety Status

  22. Safetyis Linear Extension ofFieldbus Integration (Example PN) PROFIsafedevelopmentkit PROFIsafeservices +Protocol statemachine PROFIsafe PROFINET Gateway: PROFINET IO-Link Integration("Linking Modules") PROFIsafe PROFIsafe ‒ IO-Link Safety Gateway FS-IO mapping IO-Link Safety(COM) FS-DI(OSSDe) IO-Link Safetyservices +Protocol statemachine Standardized Master Interface (SMI) ConfigurationManager (Parameter)Data Storage AcyclicDataExchange DiagnosisUnit Splitter/Composer IO-Link Safety CyclicProcessData Exchange Master layers FS-Device IO-Link Safety Status

  23. What'snext? • Finalizationofthe Test Specification in April 2019 (Draftfor WG-Review) • FS-Master and FS-Device-Tester in 3rdquarterof 2019 • "White Paper" tobe incorporated in Integration Specification PROFINET/PROFIsafe Ed. 2 • Encourageandenableother FSCP integrations (FSoE, CIP-Safety, and etc.) • IO-Link Safetyworkshop on 9thand 10thofOctober 2019 • Certified designertrainingclassesstarting in spring 2020 • Investigations on IO-Link Safetyprotocolextensionsfor IO-Link wireless (HS University, Hamburg) IO-Link Safety Status

  24. Working Group Members IO-Link Safety Status

  25. Tank you! See you…