IO-Link SafetyDigitalization down to smallest functional safe Sensors/Actuators/Mechatronics Event…Author…
Overview • Requirements of Customers and Manufacturers • WhatisOSSDe all about? • Whya newsafecommunicationprofile? • Whatdidweachieve so far? • What'snext? IO-Link Safety Status
Manufacturer's Situation Safetycontroller(FS-PLC) FS-PLC Fieldbus / FSCP Remote I/O with FS modules FS-DI Redundant signallines FS = functionalsafety PLC = programmablelogiccontroller e.g. Emergency Stop IO-Link Safety Status
Customer's Situation • Machinemanufacturerdecides on fieldbustobeuseddepending on deploymentcase • Thus, specificdevicesforeachfieldbuswith separate sparesinventory, versionmaintenanceandservicearerequired • Thus, high degreeofpersistencetostaywith "classic" interfaces such as OSSD, 4 to 20 mA, and etc. on "remote IO" fielddevices, sincetheyareindependentfromfieldbus • However: noconnectionto Internet-of-Things (IoT) andIndustry 4.0 • Numerousnewapplications: (see "Smart Manufacturing")- New sensortechnologies, e.g. strain, torque, pressure, multi-sensing, and etc.- More measuringsensors, e.g. objecttypes, distance- Mechatronics, e.g. combinationssensors/actuators • Progressive miniaturization IO-Link Safety Status
IO-Link Safetyas a Solution Fieldbuswithoneofthe FSCPs (IEC 61784-3) Remote I/O FS-Master AI AO DI DO 0 0 0 0 0 0 0 7 7 7 7 7 7 7 e.g. 0 to 10 V IO-Link Safety OSSD PM switching Analog measure- ments Digitized measure- ments Switches OSSDe or COM Relays Intelligent drives IO-Link Safety Status
Automation "hierarchy" with IO-Link Safety PLC Level Higher-Level Systems (FunctionalSafety) safety safety Fieldbus Level Enabling New Markets with IO-Link FS-Master (mappingand/orlocalprocessing) SIOMode OSSDeMode Sensor / Actuator / IO-Link Devices Mechatronic Level a Worldwide Standard with IO-Link Safety Devices FS-Devices Valves | Locking Units | Light Curtains IO-Link Safety Status
WhatisOSSDe all about? IO-Link Safety Status
Redundant Signals (OSSD) OFF state IOL-OSSDe IOL-OSSDe: Equivalentsignals Testpulses L+ OFF state IOL-OSSDe 1 C/Q 2 4 3 4,8 / 38,4 / 230,4 kbit/s I/Q COMx IO-Link Safetycommunication L- AIDA compatible! OSSD: Output SwitchingSensing Devices (Solid stateoutputs) OSSDe: = OSSD withequivalentswitchingsignals; type C, class 1 accordingto Position Paper CB24I (ZVEI) IO-Link Safety Status
Migration Strategy (example: PROFIsafe) PROFIsafe1999 FS-Master Remote IO F-Device Fieldbus(FSCP) Remote IO F-DI F-DI FS-Master andothers… IEC 61784-3-3 Develop… Connect…(Subset) Connect… Connect… Develop… IO-Link Safety2018 IO Level("OSSD") F-Sensor FS-Device ZVEICB24I OSSD New: OSSD + communication IO-Link Safety Status
"Off-Site" Parameterizationand Test (OSSDe) Off-site configuration & parameterization Fieldbus F-DI Modul FS-Master "USB Master"Tool software withsafety 0 0 0 0 IODD Remote IO USB 7 7 7 7 OSSDe "USB-Master" Parameter Test FS-Device FS-Device History IO-Link Safety Status
IO-Link Safety Communication IO-Link Safety Status
FunctionalSafety Communication Profiles (FSCP) FSCP 3 FSCP 12 FSCP 6 FSCP 1 FSCP 2 FSCP 14 FSCP 18 FSCP 13 Non-IEC"A" FSCP 17 Non-IEC "C" FSCP 8 IEC 61784-3-x:Collection of FSCPs IO-Link Safety Status
Specificationsand Assessment Reports IO-Link Safety Status
"Black Channel" Principle also with IO-Link Safety Safetyapplication Standard application, e.g. Diagnosis Standard application, e.g. Diagnosis Safetyapplication FSCP(e.g. PROFIsafe) Gateway SafetyCommunication Layer (SCL) IO-Link Safety IO-Link Safety Device(Stack) Master(Stack) IO-Link("Black Channel") Point-to-point communication IO-Link Safety Status
Messages with IO-Link Safety From FS-Master: Non-safetyProcessDataOut CRC Signature Control & M-Counter Portnumber Safety ProcessDataOut 32 to 0 octets 2/4 octets 1 octet 1 octet 3/25 octets From FS-Device: Safety Process Data In PortNumber Status & D-Counter CRC Signature Non-safety Process Data In 3/25 octets 1 octet 1 octet 2/4 octets 32 to 0 octets IO-Link Safety Status
Start-up andSecuringMeasures Communication, Identification Wake-up Ready Selftest Mastercommand SIO / OSSDe PowerOffOn PowerOffOn Cyclic Process Data exchange Configure, Parameterize Mastercommand • Safetyparameterverification (VerifyRecord) • Misconnection? (Authenticity/Port check) • Replacement? (Data Storage if "out-of-the-box") Parameter verified? Start safetycommunication (SCL) IO-Link Safety Status
Test andAssessment IO-Link Safety Status
Automatic Test Case Generation Test scripts Sequencecharts IO-Link Tester IO-Link Safety Status
FS-Master Tester (withoutfieldbusdependency) Fieldbus layers / Ethernet FSCP Gateway IO-Link/PROFINET FSCP Test FS mapping Temporarytestsignalchannel(partofthesafetyimplementation) IO-Link Safety FS-Master Standardized Master Interface (SMI) ConfigurationManager CyclicProcessData Exchange Splitter/Composer (Parameter)Data Storage AcyclicDataExchange DiagnosisUnit IO-Link safety Test Master layers Test signaldata SPDU FS-Master Tester IO-Link Safety Status
Integration example: PROFINET / PROFIsafe White Paper PROFINET Integration IO-Link Safety Status
System Overview (PROFINET / IO-Link) • Engineering System • IO controller • IO supervisor PROFINET domain • PNIO • PROFINET/PROFIsafe • IO device • GSD(IO device) • Linking Module (B)"safety" • FS-Master • IO-Link PDCT • IO-Link • IO-Link • Port 1 • Port 4 • Port 2 • Port 3 • IODD(Device,FS-Device) • IO-Link domain Off-site commissioning • FS-Devices/Devices IO-Link Safety Status
Safetyis Linear Extension ofFieldbus Integration (Example PN) PROFIsafedevelopmentkit PROFIsafeservices +Protocol statemachine PROFIsafe PROFINET Gateway: PROFINET IO-Link Integration("Linking Modules") PROFIsafe PROFIsafe ‒ IO-Link Safety Gateway FS-IO mapping IO-Link Safety(COM) FS-DI(OSSDe) IO-Link Safetyservices +Protocol statemachine Standardized Master Interface (SMI) ConfigurationManager (Parameter)Data Storage AcyclicDataExchange DiagnosisUnit Splitter/Composer IO-Link Safety CyclicProcessData Exchange Master layers FS-Device IO-Link Safety Status
What'snext? • Finalizationofthe Test Specification in April 2019 (Draftfor WG-Review) • FS-Master and FS-Device-Tester in 3rdquarterof 2019 • "White Paper" tobe incorporated in Integration Specification PROFINET/PROFIsafe Ed. 2 • Encourageandenableother FSCP integrations (FSoE, CIP-Safety, and etc.) • IO-Link Safetyworkshop on 9thand 10thofOctober 2019 • Certified designertrainingclassesstarting in spring 2020 • Investigations on IO-Link Safetyprotocolextensionsfor IO-Link wireless (HS University, Hamburg) IO-Link Safety Status