1 / 47

Round Robin II Calibration/Test Results

Round Robin II Calibration/Test Results. Impact of Burner Tab and Intake Duct on Calibration/Test Results. Variations in Burner Air Turbulators Discovered. Round Robin II Calibration Requirements. Air Intake Velocity: 2150 +/- 50 ft/min. Thermocouple Rake Temperatures: 1850+/- 100 o F.

Download Presentation

Round Robin II Calibration/Test Results

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Round Robin II Calibration/Test Results • Impact of Burner Tab and Intake Duct on Calibration/Test Results • Variations in Burner Air Turbulators Discovered

  2. Round Robin II Calibration Requirements • Air Intake Velocity: 2150 +/- 50 ft/min • Thermocouple Rake Temperatures: 1850+/- 100oF • Heat Flux: 16.0 +/- 0.8 Btu/ft2 sec

  3. Round Robin II Recommended Burner Configuration • Igniters @ 10:00 Position • 1 Tab in Top Left Position • Static Disc In Draft Tube • 3.75-Inch Distance from Nozzle Tip to Turbulator

  4. Round Robin II Material Combinations: 1) 2 Layer 0.60 lb/ft3 Fiberglass 2) 1 Layer Nextel Ceramic Paper/2 Layer 0.42 lb/ft3 Fiberglass 3) 2 Layer 0.60 lb/ft3 Curlon 4) 1 Layer TTI Felt/1 Layer 0.42 lb/ft3 Fiberglass

  5. FAATC Round Robin II Tab/Igniter Arrangement

  6. FAATC Round Robin II Tab/Igniter Arrangement

  7. Various Burner Arrangements Used in Round Robin II

  8. Influence of Tab and Intake Duct on Calibration and Test Results

  9. Position of Flame Deflection Tab

  10. 4 Burner Configurations: No Tab/With Duct (NTWD) No Tab/No Duct (NTND) With Tab/With Duct (WTWD) With Tab/No Duct (WTND)

  11. Tab/Intake Duct Test Conclusions Burner Calibration Influenced More From Tab Than Duct Test Results Influenced More From Burner Set-up Than Calibration No Tab = Temp Calibration = Quicker Failure Time /

  12. Influence of Turbulator on Calibration and Test Results

  13. Differences Between “Old” and “New” Park Burners Old New 2 3/4-Inch Turbulator 2 5/8-Inch Turbulator Opposing Turbulator Flow Identical Turbulator Flow No Static Disc Static Disc

  14. Old and New Style Turbulators Old New 2 3/4” I.D. 2 5/8” I.D. C.W. C.W. C.C.W. C.W. 4” O.D. 3 7/8” O.D. No Disc Disc

  15. Burner Equipment Assortment

  16. Monarch H215 Turbulator with Static Disc