230 likes | 351 Views
Post Run13 MuTR / MuTrig Maintenance. Cathode Cable in mis -contact : South Station-1 Oct-5, Gap-2. High Noise Rate in South St-1 Oct-3 Gap-2. North Station-3 Octant-1. See next page for gap decomposition. North Station-3 Octant-1 stands out. North Station-3 Octant- 1 Gap-2.
E N D
North Station-3 Octant-1 See next page for gap decomposition North Station-3 Octant-1 stands out
North Station-3 Octant-1 Gap-2 <-Gap-1 is OK
South HV Been bad from the past. Attempted to fix during Run12 shutdown. But couldn’t fix. Cause may be inside.
MuTr HV Trip History Run13 South Lost HV module 90days * HV trip due to communication failure are excluded North N351 N331 N311
Need to change FEE boards North Arm Oct-3 Anode Trippy HV 11300 S3 O2 C6 HV St-3 Oct4 N341-0 Station-1 Oct-5 Anode Trippy HV Noisy ADTX Check grounding & trippy HV 11195 S1 Q3 C3 West East 11343 S3 O7 C1 Station-2,3
South Arm 11064 S2 O3 C4 11134 S3 O4 C5 Station-2,3 Noisy ADTX Check Grounding HV St3, Oct1 S311-0 (couldn’t fix) West East HV St3, Oct7 S371-6 (couldn’t fix) 11137,11138 S3 O5 C2
MuTr RX Card Debugging (1) • RX card transmits electrical signal to optical. • We have only 3 spare good boards and 7 spare boards to be debugged. • To be tested at John Haggerty’s test bench. MUTR electrical optical DCM FEE RX card
MuTr fiber labeling • Redo MuTr fiber labeling at DCM. • The new label suppose to have Module# and dsp# as well.
Debugging MRG FPGA FPGA: verilogHDL Above two octants are running with older version of MRG FPGA in Run13. Both are observable with cosmic circumstances South Octant-3 Run12 Octant-1 Cosmic SG1~50kHz South Run12 Octant-1 Physcs SG1~1kHz Plot by Dahee (Ewha University) North
Summary • So far high rates in both Oct-1 and Oct-3 are both disappears with down graded MRG FPGA code. • Whether we run with mixed two FPGA code? • Down grade all octants? • Confirm stability using cosmic as long as possible.
When did this started? - runtype: CALIBRATION data - triggerconfig: PP510Run12_Cosmic - run time > 10 min - MUIDLL1_N1D||S_1D trigger enabled. FPGA Upgrade (Mar. 28, 2012) S_SG1 rate 40kHz Octant-3 Threshold=20mV for Cosmic Runs. FPGA Upgrade (Mar. 28, 2012) Run Rate[kHz]
Run13 Threshold Response of Octant-1 Run12 Octant-1 Cosmic SG1~50kHz Run12 Octant-1 Physcs SG1~1kHz South Plot by Dahee (Ewha University) North Run12 Cosmic Rate ~40kHz is consistent with present measurement. Physics run was operated at 30mV and likely to be operated around 1kHz.
Time dependent rate in Run12 Cosmic mrg_prom021 S_SG1 Rate mrg_prom036 mrg_prom036 mrg_prom036 No indication of Oct-3 High rate excursion. Hidden under Oct-1 40kHz? Need Time dependent LL1SG1 rate Oct-by-Oct -> Josh developed in the past?
Octant-1 Diagnosis • Station-1, Station-2 Mask Station-3b (done) • Chip scope measurement using LL1 fire as trigger of chip scope • Check the communication between MRG and LL1. How we know the communication error? • Check the timing alignment error. • Play with delay scan level-1 internal clock.(require LL1 FPGA modification) • Perform MRG (process) delay scan (all stations at once) more precisely (to find the timing when LL1 started to fail align),
North Arm Need to change FEE boards Station-2,3 Station-1 11300 S3 O2 C6 Noisy ADTX Check grounding West East
South Arm Station-2,3 Noisy ADTX Check Grounding West East