1 / 19

Branching ratio measurement of the SM-like Higgs decay into μ + μ - at 1.4 TeV CLIC

Branching ratio measurement of the SM-like Higgs decay into μ + μ - at 1.4 TeV CLIC. Gordana Milutinovic-Dumbelovic Vinca Institute of Nuclear Sciences, Belgrade Ivanka Bozovic-Jelisavcic , Strahinja Lukic , Mila Pandurovic. CLIC Workshop, February 3-7, 2014, CERN, Geneva . Overview.

selima
Download Presentation

Branching ratio measurement of the SM-like Higgs decay into μ + μ - at 1.4 TeV CLIC

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Branching ratio measurement of the SM-like Higgs decay into μ+μ-at 1.4 TeV CLIC GordanaMilutinovic-Dumbelovic Vinca Institute of Nuclear Sciences, Belgrade IvankaBozovic-Jelisavcic, StrahinjaLukic, Mila Pandurovic CLIC Workshop, February 3-7, 2014, CERN, Geneva

  2. Overview • Motivation for the measurement • ILD detector for CLIC • Electron tagging in the forward region • Signal and background processes • Event selection and MV analysis • Method of the measurement • Conclusions CLIC Workshop 2014 , GordanaMilutinovic-Dumbelovic

  3. Motivation for the measurement • Higgs BRs measurements are potential probe for the New Physics (i.e. models that could possibly extend SM Higgs sector impact Higgs couplings to EW bosons and/or Higgs Yukawa couplings) • Challenging measurement due to low signal yield (predicted BR( ) 10-4) : Background has to be efficiently suppressed Requires excellent momentum resolution i.e. in the barrel , as foreseen in CLIC CDR CLIC Workshop 2014 , GordanaMilutinovic-Dumbelovic

  4. ILD detector for CLIC MuonpT reconstruction translates into m(μμ) mass width  statistical uncertainty of the measurement • Iron yoke instrumented with 9 active layers for μ identification • average pT resolution in the barrel • region, on the signal sample CLIC Workshop 2014 , GordanaMilutinovic-Dumbelovic

  5. Electron tagging in the forward region • - If escapes at very small angles, undetected electron can mimic missing energy signature of the signal • Forward region below ~ 7 deg is instrumented with calorimeters to (among others) tag (high-energy) electron • However, detectors are overflowed with background from incoherent pairs • Electron is tagged if reconstructed shower energy deviates for 4 from the pair depositions in the layer with maximal deposition • In order to reduce coincidence with Bhabha events, polar angle of the rec. shower is required > 30 mrad CLIC Workshop 2014 , GordanaMilutinovic-Dumbelovic

  6. Signal and background processes Background Signal CLIC Workshop 2014 , GordanaMilutinovic-Dumbelovic

  7. Signal and background processes • The most important kinematical property of signal is missing energy. • Process with the same signature like and • give irreducible background (even after MVA) • - Processes like and with low-angle electron in the final state can be dealt with in MVA + electron tagging • - We added the full simulation of background including now the overlay of resulting in a change of Evis distribution (reduced MVA separation) CLIC Workshop 2014 , GordanaMilutinovic-Dumbelovic

  8. Signal and background processes AIncluding a cut of 100GeV <M( )<140GeV and requiring a minimal polar angle for both muons of 8°. CLIC Workshop 2014 , GordanaMilutinovic-Dumbelovic

  9. Event selection and MV analysis • 1.5 ab-1 corresponding to 4 years operation with 50% data taking efficiency. • Pre-selection: • two reconstructed muons, (105-135) GeV • di-muon mass window • absence of a E>200 GeV electron at on side of the FWD calorimeters – electron tagging CLIC Workshop 2014 , GordanaMilutinovic-Dumbelovic

  10. MVA • TMVA input(Evis, pT(), pT(1)+pT(2), (), cos *, ()). • BDT is trained on: CLIC Workshop 2014 , GordanaMilutinovic-Dumbelovic

  11. Background suppression with MVA BDT>0.064 • BDT cut corresponds to the minimal relative statistical errormaximization of significance or purity∙efficiency • MVA selection efficiency is 40% for signal. • Overall signal efficiency is 33%. CLIC Workshop 2014 , GordanaMilutinovic-Dumbelovic

  12. Before - after MVA • is reduced about 3 orders of magnitude • Emis signature background irreducibly present CLIC Workshop 2014 , GordanaMilutinovic-Dumbelovic

  13. Method of the measurement Signal and background PDFs Fully simulated, as large as possible, samples of signal and background to extract PDFs SIGNAL ALL BACKGROUND CLIC Workshop 2014 , GordanaMilutinovic-Dumbelovic

  14. Method of the measurement Toy MC experiments • Pseudo-experiments based on randomly sampled fully simulated signal events + backgrounds generated with PDFs • Expected shape of data (signal + background) for each Toy MC is fitted with f to extract number of signal Ns CLIC Workshop 2014 , GordanaMilutinovic-Dumbelovic

  15. Method of the measurement Statistical uncertainty 5000 Toy MC experiments is performed to extract statistical uncertainty and check the pull distribution • RMS from Ns distribution give us statistical uncertainty of the measurement • Pull distribution confirms adequate description of signal and background with PDFs CLIC Workshop 2014 , GordanaMilutinovic-Dumbelovic

  16. Results • - Uncertainty of the measurement is dominated by the small  statistics of signal and by the backgrounds with (true) missing energy. • One should not that no polarization is included that can boost statistics by a factor 2. • Uncertainty of the gH (12%) is estimated assuming uncertainties of gHWW and H as in the Snowmass paper. • Processes and has to be treated in EPA for low momentum transferred by the exchanged photon. In that kinematical region electron is substituted by a quasi-real photon. CLIC Workshop 2014 , GordanaMilutinovic-Dumbelovic

  17. Conclusion • H→ μ+μ- analysis at 1.4 TeV completes Higgs BRs studies at CLIC energy stages. • All relevant backgrounds are considered as well as a realistic electron tagging performance in the forward region. • It has been shown that BR(H→ μ+μ- ) can be measured with astatistical accuracy of order of 30+ percent (the exact number will be provided after we introduce EPA) • Uncertainty of the measurement is dominated by the small  statistics of signal and by the backgrounds with (true) missing energy. CLIC Workshop 2014 , GordanaMilutinovic-Dumbelovic

  18. BACKUP

  19. Systematics - Peak luminosity (estimated to be determined within ~1.4 permille at 3 TeV CLIC - Systematic uncertainty of the signal count is relatively insensitive to the accuracy of the pT resolution - Uncertainties of the polar angle resolution and muon identification efficiency are expected to be at the percent level as at LEP - Coincidence with Bhabha events with 10ns (20 BX) time stamping is found to be 7% CLIC Workshop 2014 , GordanaMilutinovic-Dumbelovic

More Related