1 / 11

TRD DAQ (U) Software Status TIM CERN May.09

TRD DAQ (U) Software Status TIM CERN May.09. Chanhoon Chung, Mark Millinger, Andreas Sabellek IEKP - Universität Karlsruhe (TH). TRD(U) DAQ Overview. Outline UDR2 / JINFU DSP Software U-Crates SlowControl/HK Data Basic Monitoring Tools Development. TRD Offline DAQ Status

seoras
Download Presentation

TRD DAQ (U) Software Status TIM CERN May.09

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. TRD DAQ (U) Software StatusTIM CERN May.09 Chanhoon Chung, Mark Millinger, Andreas Sabellek IEKP - Universität Karlsruhe (TH)

  2. TRD(U) DAQ Overview Outline • UDR2 / JINFU DSP Software • U-Crates SlowControl/HK Data • Basic Monitoring Tools Development TRD Offline DAQ Status Gas: Premixed Ar/CO2 (80/20) Readout Electronics: U0: QM U-Crate and UPD U1: QM and FS equipped U-Crate recording cosmics since July08 Readout: AMSW/Trigger via EPP-AMSW box; Recording to AMS Block files Trigger: pulsed @ 2kHz TIM May09, CERN

  3. Data ReductionUDR2 DSP Software • current version v9318 (March,24th) based on framework v9310 by A.Kounine • optimized processing time ~240us/single-track-event • unassgined bits used to submit readout chip noise with hit amplitude • added HK data for DAQ status monitoring: • UFE hit counter / running mean common noise (e.g. new calibration?) • channel hit counter / running mean hit amplitude (e.g. change in gas?) • Status: Code in use in TRD Offline DAQ Framework v9310 SubD routines • Calibration: • - Test of channel quality and setting of channel flags • Calculation of pedestals • Calculation of noise • Data Reduction: • Pedestal Substraction • Zero Suppression • Channel Flag handling • (e.g. force output of • a channel) • HK data: • hit counter • amplitude averaging TIM May09, CERN

  4. Slow ControlJINFU DSP Software • current version v941A (April,26th) based on framework v9310 by A.Kounine • initialization/reset of U-Crate HW according configuration file in flash • 16 FPGAs and 168 high voltage controllers • status readout of U-Crate HW • long status: complete HW configuration readback • short status: JINF compares readback with expected setting and replies discrepancies only • init/ramping of high voltage specified in configuration file • Status: Code used in TRD Offline DAQ system parameters: LeCroy LRDL/ HRDL UPD S9011AU Controller JINF_U0/1: collects and assembles status data from nodes on request JMDC: Qlist requests status info AMSwire HK datastream to disk UPSFE boards UHVG boards TIM May09, CERN

  5. Summary: TRD Housekeeping Data • UDR2 (status DAQ) • Calibration data (channel pedestal/noise) • Status of data acquisition (channel hit counter/amplitude) • JINFU (status SlowControl) • Status from UPD-Box DCDC converters and U-Crate electronics • Status of U-Crate UHVG high voltage channels • UGSCM (status Gas via CAN-bus; next presentation) AMSWire sources for TRD DAQ monitoring: Recording HK data with science data in AMS Block File format during last weeks TRD Offline operation for test TIM May09, CERN

  6. TRD-M • development by Chanhoon Chung • Need a quick and reliable diagnosis tool for monitoring TRD HK data • based on CCEB-Monitor developed by A.Basili/A.Lebedev using xforms-libs and AMSblock decoding TRD Housekeeping data in TRD-M following: examples …–M programs known to everyone TIM May09, CERN

  7. Example: Strawtube Noise TIM May09, CERN

  8. Example: JINFU (short)Status TRD SlowControl status can be summarized in number of discrepancies from nominal U0-Crate: no problems U1-Crate: known reason: missing 2nd QM UPD TIM May09, CERN

  9. TRD Dallas T Sensor Monitor • development by Mark Millinger • graphics required to identify location • implemented on basis of Monitor programs by A.Basili and A.Lebedev TIM May09, CERN

  10. TRD DTS Monitor sensor area temperature averaging in different layers TIM May09, CERN

  11. Summary • Initialization based on JINF configuration file implemented • Development of monitoring tools based on common framework ongoing • to be done: “TRD-Control” • Graphical Interface indicating status of system components analyzing HK data • and providing tools to quickly identify problems • Create configuration file • TRD DAQ still running next: Francesca Spada, TRD GAS (UG) TIM May09, CERN

More Related