1 / 25

New Product Overview Homac STORM SAFE ™ Connector Systems Presented by: Roy Jazowski - Director of R&D Mark Ha

New Product Overview Homac STORM SAFE ™ Connector Systems Presented by: Roy Jazowski - Director of R&D Mark Hammer – Director of Marketing & Sales. New Homac STORM SAFE ™ Device: . In 2005, Homac and the “Electric Power Research Institute” EPRI, entered into an agreement to

september
Download Presentation

New Product Overview Homac STORM SAFE ™ Connector Systems Presented by: Roy Jazowski - Director of R&D Mark Ha

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. New Product Overview Homac STORM SAFE™ Connector Systems Presented by: Roy Jazowski - Director of R&D Mark Hammer – Director of Marketing & Sales

  2. New Homac STORM SAFE™ Device:

  3. In 2005, Homac and the “Electric Power Research Institute” EPRI, entered into an agreement to jointly develop a family of connector devices which would break during hurricane/storm conditions when service entrance power lines are hit with trees, branches or flying debris Project Overview

  4. The goal of the project was to design a family of products which would: Mitigate damage to power line structures and systems Restore power quickly Eliminate damage to customer’s service entrance equipment Project Overview

  5. Improve SAIFI (System Average Interruption Frequency Index) and SAIDI (System Average Interruption Duration Index) for utilities using Storm Safe products during severe weather conditions Additional Project Goals

  6. Improve safety to the public and repair crews by insuring that the lines are de-energized when they fall to the ground Improve utility reliability by restoring power quickly, with no costly repair charges to both the utility and the customer Additional Project Goals

  7. Improve site safety during storm damage conditions The Challenge • Find a way to mitigate damage to service wires, customer equipment & secondary performance

  8. Product Overview

  9. Benefits • SAIDI improved – faster restoration time • SAIFI improved – secondary stays in as service clears without tripping primary mitigating additional downstream outages • O&M Costs – no damage to terminal pole and minimal exposure to service damage, faster restoration time • Customer satisfaction – avoids need for entrance repairs ($800 – $2,500), restoration faster, less transient exposure • Safety • Homeowner – mitigates transients • Public – wires are deenergized on the ground • Crews – wires are dead and clear

  10. Field Experience STORM SAFE w/ 3 Services Three months after proto installation, tree took one service down Second and third service drops remained intact Service mast survived

  11. Field Test @ KCP&L

  12. STORM SAFE can be applied in any overhead service drop application. It is adaptable to any location: Mechanical Breakaway sized to utility specification Multiple drops served off 1 STORM SAFE(1-3 on one pole) Single drop for low density or wide spread, such as opposite sides of the pole New construction or retrofit; pre or post storm Restore service with a new fuse link; plug and energize Unique Homac, Patented Solution Available 3rd Quarter 2006 Project Results

  13. About Homac • Founded in 1963 • Private Company – 2nd Generation Family Owned • Florida Based Manufacturer Serving the Electric Utility • Leading Producer of Electrical Connectors and Cable Acc. • 425 Employees • 3 Manufacturing Locations • □ Ormond Beach, FL Corporate Headquarters, Manufacturing • and Distribution Facilities 140,000 sq. ft. • □ Ormond Beach, FL Automated CNC and Plating Facilities 44,000 sq. ft. • □ Corcoran, CA Manufacturing and Dist Facilities 38,000 sq. ft. • Manufacturer of the Year – Volusia County, FL

  14. Ormond Beach, FL Headquarters

  15. Ormond Beach, FL Headquarters

  16. Serving the Power Distribution Sector of the Electric Utility Industry

  17. Our Customers: • Investor Owned Utilities • Rural Electric Cooperatives • Municipal Electric Utilities Serving Customers Across the United States and in over 40 Countries World-Wide

  18. Our History In the early 1960’s, electric utility companies began to transition from overhead distribution lines to underground installations In 1964, Homac’s founder invented and patented the 1st connector designed specifically for underground residential distribution (URD) – the Homac “Hub” connector

  19. Our History Homac pioneered the use of EPDM rubber for insulating and waterproofing underground cable connectors Homac’s “Flood-Seal”® technology provided a unique, cost- effective solution to the industry – and a preferred alternative to epoxy, tape and heat-shrink for underground cable joints

  20. Our History • Designing underground connectors with • interference-fit rubber’s stretch and memory • characteristics provides superior tension on • the cable-connector interface resulting in • indefinite waterproof integrity

  21. Our History Today, Homac has grown to become the leader in the design and manufacture of electric power delivery connector solutions Homac is the industry’s largest manufacturer of secondary underground distribution connectors And a recognized leader in overhead distribution and substation connectors

  22. Complete Line of Quality ElectricalConnectors &Accessories_______________* Aluminum & Copper* Compression & Mechanical* Overhead & Underground* Flood-Seal® Insulating Products Homac Products

  23. SubstationConnectors _______________* Aluminum & Bronze* Bolted & Welded* EHV Homac Products

  24. Underground Distribution Systems Facts: • Improving Electric System Reliability is Driving U/G Growth • U/G Electric Systems Mitigate Outages Due to Severe Weather • Improving the Aesthetics of the Electric System is Driving U/G Growth • Security Concerns May Help Drive Additional U/G Growth • U/G Cable Placement Growing 8 Times the Rate of O/H • Today, Less Than 15% of Distribution Cable is Currently U/G • Homac Supports National, State & Customer Initiatives That Focus On Improving the Electric Power Delivery Infrastructure, Electric System Reliability & Electric System Safety!

  25. Thank You

More Related