260 likes | 828 Views
What you will learn. Ignition TypesS8910U1000Features and BenefitsInstallation and Set Up TroubleshootingS8910U AdvantageProduct Cross Reference Information. Ignition Sources. There are 3 different ways a burner can be ignited:1) Standing Pilot Ignition2) Intermittent Pilot Ignition In
E N D
1. S8910U1000Universal Electronic Ignition Modules Training Module
2. What you will learn Ignition Types
S8910U1000
Features and Benefits
Installation and Set Up
Troubleshooting
S8910U Advantage
Product Cross Reference Information
3. Ignition Sources There are 3 different ways a burner can be ignited:
1) Standing Pilot Ignition
2) Intermittent Pilot Ignition
Intermittent Pilot - S8610U
3) Direct Burner Ignition
Hot Surface Ignition – S8910U
Direct Spark Ignition – S87
4. S8910U1000
5. Universal Hot Surface Ignition Module What is the S8910U1000?
Electronic control of direct hot surface Ignition systems used on gas fired furnaces, boilers, and other heating appliances
Operating control of a direct ignition system using a 120 Vac hot surface igniter
No spark generator
Simple relay to power igniter
Two wires to gas valve
6. S8910U Features – The Universal Choice Features
Universal Compatibility
Replaces over 100 Honeywell and competitor models.
“Personality” Plug-Ins- match the ignition sequence of the model being replaced using the plug in selector tabs and cross reference chart for an instant equivalent of the old control.
Application Flexibility
Use with Single Rod or Dual Rod Systems
Works with both Natural or LP gas
Easy Installation
Easy-to-use instructions plus the adaptation accessories required to adapt the existing hot surface ignition module
Accessory kit includes: White-Rodgers adapter, Robertshaw ground lead, four Ľ” female .032 quick-connects, one 3/16” female .032 quick connects, four selection tabs and seven wire labels.
7. The Universal Choice continued…..
LED diagnostics
Quickly troubleshoot and diagnose any problems with the system
Ignition Trials
Provides one or three ignition trials (4-second or 7-second trials) per call for heat
Prepurge of 32-seconds or less
Up to 90-seconds between purge cycle times
Excellent industry acceptance
The Honeywell brand is recognized as a top performer in the industry
8. S8910U Features
9. Installation and Set Up
10. Installation of the S8910U Mount the module
Do not mount with terminals facing up
protect the module from exposure to water, moisture, corrosive chemicals and excessive dust and grease.
Install selection tab (“personality plug-ins”)
The number of trials for ignition and trial time is determined by the selection tabs.
Four selection tabs are included with the S8910U. (A,B,C,D)
Without a selection tab, the module operates at four-second trial time and one ignition.
Selection tabs A and B — 4 seconds.
Selection tabs C and D — 7 seconds.
Wire the module
Use diagrams in installation instructions for wiring
11. Selection Tab Installation
12. Selection Tab Cross Reference
13. Select Timing & Tries
14. Troubleshooting
15. LED Indicator Light Flashes Meaning
Pulse Normal operation
1 Lockout
2 Flame signal
3 Internal
16. Troubleshooting of the S8910U
17. Troubleshooting of the S8910U
18. Product Cross Reference
19. Product Cross Reference Where do I find Honeywell electronic ignition cross reference and selection information?
www.customer.honeywell.com
Honeywell Application Selection and Cross
Reference Guide – Form 63-9575
Honeywell Laminated Truck Visor – Form 63-9581
Honeywell Gas Counter Mat – Form 63-9580
Honeywell Residential Technical Support: 1-800-468-1502
20. Product Cross Reference Guide
21. www.customer.honeywell.com See Cross Reference Search box in right column
22. The S8910U Advantage When promoting the S8910U keep these advantages in mind:
The S8910U replaces over 100 Honeywell and competitor’s ignition modules; reduces inventory by stocking one versus many and saves time and money looking for the right part.
Easy to use instructions and adaptation accessories saves the contractor valuable time and resources.
Personality” Plug-Ins - match the ignition sequence of the model being replaced using the plug in selector tabs for a true Universal replacement.
The S8910 is application flexible and can be used with single rod or dual rod systems, and natural or LP gas.
The diagnostic LED makes troubleshooting simple, identifying ignition lockout, flame rectification signal and control failure, solving the problem quickly and satisfying the customer.
23. S8910U Universal Electronic Ignition Knowledge Test
24. Now that you completed this training module, take the short quiz to test your knowledge.
25. Test The S8910U1000 is a hot surface ignition module? T or F
The S8910U is application flexible and works with single or dual rod systems? T or F
The S8910U can be used with LP gas only? T or F
The LED light displays the following: normal operation, lockout, weak flame signal and internal error? T or F
If the internal error signal is still present after a new call for heat the S8910 can be repaired, it does not have to be replaced? T or F
26. Test The S8910U has “personality plug-ins” to match the ignition sequence of the control being replaced? T or F
An ignition sequence must be chosen as there is no factory set sequence? T or F
The adaptation accessory kit includes parts to convert from White Rodgers and Robertshaw controls? T or F
The Honeywell S8910U replaces over one hundred Honeywell and competitive ignition modules? T or F
The Honeywell S8910U is widely recognized in the industry as a top performer in the industry? T or F
27. Answer Key T
T
F
T
F
T
F
T
T
T