Eye and Pen and eye tracking devices. Eye and Pen currently support : EyelinkII, Eyelink 1000 (S.R. research , Ltd.) i-ViewX HED (SensoMotoric Instruments GmbH, S.M.I.) ASL 504 (Applied Science Laboratories, A.S.L.) [ support for ASL5000/6000 series is on the way ] EyePuter (Alphabio ).
E N D
Eye and Pen and eye tracking devices • Eye and Pen currently support: • EyelinkII, Eyelink 1000 (S.R. research, Ltd.) • i-ViewX HED (SensoMotoric Instruments GmbH, S.M.I.) • ASL 504 (Applied Science Laboratories, A.S.L.)[ support for ASL5000/6000 series is on the way ] • EyePuter (Alphabio) Install each eye tracker following its manufacturer’s manual. If using an S.R. Research eyetracker, install the Display PC Software on the computer running Eye and Pen (includes required librairies). Eyelink and i-ViewX require an Ethernet cable and a network adapter. ASL504 and EyePuter require a serial cable. 10-12 April 2012, Mshs, University of Poitiers, France
Using the eye tracker in Eye and Pen 1. Configure the eye tracker as an acquisition device Select the Configuration | Acquisition menu. 10-12 April 2012, Mshs, University of Poitiers, France
1. a. Select the eye tracker model / brand Tick this box to enable eye tracker recording Click this button to set options for this eye tracker “Tablet” is not a true eye tracker, but the ability to record pen movements data (even when pen is “in the air” above the surface) like if it was an eye tracker. This “model” has no options to set. 10-12 April 2012, Mshs, University of Poitiers, France
1. b. Options for EyelinkII Allows Eyelink host to record data in its own files and format Calibration uses a “disk” with a hole in the center Hint: choose a color close to the “global” color of what you will display during experiment (pupil dilatation control). Select a color Unique calibration point used to check calibration validity during experiment Selects the center of the (current) screen Only one eye will be recorded, Eye and Pen does monocular Hint: drift test can be invoked by script at any time during an experiment. 10-12 April 2012, Mshs, University of Poitiers, France
1. c. Set eye tracker options Tick this box to discard successive identical data (coordinates) When ticked, starting the eye tracker will automatically launch its own calibration procedure(not supported by ASL and Eyeputer). Must be set “by hand” (most eye tracker do not return this information) 10-12 April 2012, Mshs, University of Poitiers, France
1. d. Set calibration options Select the whole screen for calibration Calibration takes place in a window (can be smaller than the screen) When ticked, Eye and Pen will provide a window for calibration (required for Eyelink) You will calibrate using a screen or an LCD tablet A picture can be seton screen You will calibrate using a classic tablet: a calibration “on paper” should be performed Eye and Pen will wait until the ESC key is pressed to end the calibration procedure 10-12 April 2012, Mshs, University of Poitiers, France
2. Testing the eye tracker Select the Device tests | Eye tracker | Visual menu. gaze coordinates gaze location is realized under the shape of a cross on the screen 10-12 April 2012, Mshs, University of Poitiers, France