1 / 46

Current practice of PM-measurements, data processing, interpretation and visualization in Belgium

Current practice of PM-measurements, data processing, interpretation and visualization in Belgium. Frans Fierens scientific staff member of the Flemish Environment Agency (VMM) at the Belgian Interregional Environment Agency (IRCEL) PM_lab workshop, 2010 March 4. IRCEL-CELINE ?.

shilah
Download Presentation

Current practice of PM-measurements, data processing, interpretation and visualization in Belgium

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Current practice of PM-measurements, data processing, interpretation and visualization in Belgium Frans Fierensscientific staff member of the Flemish Environment Agency (VMM) at the Belgian Interregional Environment Agency (IRCEL) PM_lab workshop, 2010 March 4

  2. IRCEL-CELINE ? NL : Intergewestelijke Cel voor het Leefmilieu FR : Cellule Interrégionale de l'Environnement EN : Belgian Interregional Environment Agency Agreement between the 3 Belgian Regions (1994) • Major tasks : • SMOG (winter/summer) warnings (IDPC) • Interregional Calibration Bench • Interregional AQ Database (3 Regions) • Scientific support • Reports EU-COM / Experts EU-working groups

  3. Contents • Choice of PM-Measurement locations • Calibration of PM-Measurements - equipment • Future technical development in the next 2-3 years • Data acquisition - Handling of PM-data • Spatial Interpolation of PM-point data • Forecast Modelling (deterministic / statistical models).

  4. Contents Choice of PM-Measurement locations Calibration of PM-Measurements - equipment Future technical development in the next 2-3 years Data acquisition - Handling of PM-data Spatial Interpolation of PM-point data Forecast Modelling (deterministic / statistical models).

  5. Number of PM10 and PM2.5 monitoring stations • PM10 : start measurements in 1996 • PM2.5 : start measurements in 2000 PM10 (telemetric stations)(>90% valid daily averages) PM2.5 (telemetric stations)(>90% valid daily averages) Beside PM : also BC and Black Smoke measurements

  6. Location of PM10 telemetric stations PM10 : monitoring stations • Locations mostly : • Industrial • Urban or Urban Background • Very few “rural” • and “traffic” stations • (Historical reasons)

  7. Location of PM2.5 telemetric stations PM2.5 : monitoring stations • Locations mostly : • Industrial • (Sub) Urban • Very few “rural” • and “traffic” • “AEI stations” : • Bruges(*) • Ghent (*) • Antwerp : 2 (*) • Brussels : 2 • Liège • Charleroi • (*) not on the map

  8. Contents Choice of PM-Measurement locations Calibration of PM-Measurements - equipment Future technical development in the next 2-3 years Data acquisition - Handling of PM-data Spatial Interpolation of PM-point data Forecast Modelling (deterministic / statistical models).

  9. PM measuring techniques in Belgium • Flanders - Oscillating Micro Balans (TEOM and TEOM-FDMS) • Bèta Absorption (ESM FH62I-R) • Gravimetric : • Equivalence tests • PM2.5 (to calculate the Average Exposure Index “AEI” on urban-background locations, started in 2009) + 1 Rural background location • Brussels- Oscillating Micro Balans (only TEOM-FDMS since 2004-2005) • Wallonia- Bèta Absorption (MP101 integration time 24h)- Optical techniques (GRIMM)

  10. Automatic PM monitors <> EU reference method PROBLEM : automatic monitors <> EU (gravimetric) reference method NO PROBLEM : When “equivalence” is demonstrated

  11. Current “calibration”of PM in Belgium (*) based on the ‘guide for the demonstration of equivalence of ambient air monitoring methods’ (Excel templates from the JRC) (**) preliminary results of an equivalence program in Wallonia result in somewhat higher calibration factors

  12. New comparative campaign (VMM) : PM10 “calibration” factors calculated in new campaign are slightly higher than previously “Comparative PM10 and PM2.5 measurements in Flanders (Belgium)”, VMM, Period 2006 - 2007 (www.vmm.be)

  13. First comparative campaign (VMM) : PM2.5 Higher “calibration” factors for PM2.5 than for PM10 -> higher volatile fraction “Comparative PM10 and PM2.5 measurements in Flanders (Belgium)”, VMM, Period 2006 - 2007 (www.vmm.be)

  14. Spatial and temporal variation of calibration factors

  15. Contents Choice of PM-Measurement locations Calibration of PM-Measurements - equipment Future technical development in the next 2-3 years Data acquisition - Handling of PM-data Spatial Interpolation of PM-point data Forecast Modelling (deterministic / statistical models).

  16. Future technical development in the next 2-3 years (1) • Flanders : • - More “Chemkar” campaigns ( PM10 “hotspots”,Rural • vs Urban PM10 & PM2.5, Antwerp harbour, …) • - Measuring the effect of Woodburning on PM (levoglucosan) • Additional measuring stations (e.g. Streetcanyon NO2/PM)- Testing of new Bèta-monitors (BAM1020, FAI SWAM 5DC) • UFP measurements (streets) • Further participating in CEN/TC264/WG15 : • * revision of the PM10 standard EN12341 • * revision of the PM2.5 standard EN14907

  17. Future technical development in the next 2-3 years (2) • Brussels : • - “Black Carbon” measurements • - “Counting Particles” (using GRIMM monitors) • Wallonia : • additional measuring stations (e.g. Tournai, Namur) • EC/OC analyser at Vielsalm (Rural background) • Interregional (IRCEL-CELINE) : • further developing Interpolation techniques (eg. use of satellite observations like AOD)- higher spatial resolution modelling • (forecasts + assessment)- implementation of data assessment techniques

  18. Contents Choice of PM-Measurement locations Calibration of PM-Measurements - equipment Future technical development in the next 2-3 years Data acquisition - Handling of PM-data Spatial Interpolation of PM-point data Forecast Modelling (deterministic / statistical models).

  19. Data acquisition of automatic measurements Monitoringstation RDRC “Regional Data Processing Centers” Every hour (26’ after each hour) -> ½ - hourly measurements -> FTP to IRCEL servers -> calculation of hourly / 8-hourly / 24-hour averages. -> publication real-time data + maps on websites IRCEL

  20. “Real-Time” publication on websites - tables

  21. “Real-Time” publication on websites - maps

  22. Contents Choice of PM-Measurement locations Calibration of PM-Measurements - equipment Future technical development in the next 2-3 years Data acquisition - Handling of PM-data Spatial Interpolation of PM-point data Forecast Modelling (deterministic / statistical models).

  23. How to define a scientifically based methodology for assessment of spatial representativeness? CORINE land use map

  24. RIO-Corine interpolation VITO + IRCEL developed the RIO-corine methodology • Observation: • Sampling values depend on land use in (direct) vicinity of the monitoring site • Consequence: • Interpolation scheme needs to know this relation between land use and air quality levels • Approach : • Create land use indicator to express this relation

  25. RIO - Land use indicator (1) 2 km • Land use indicator • For each station: • Determine buffer (e.g. 2km radius) • Characterize land use by CORINE class distribution inside buffer

  26. RIO - Land use indicator (2) <PM10> Land use indicator is based on CORINE class distribution Calibration of coefficients ai : multi-regression to optimize trend for mean and standard dev. of monitoring data <NO2>

  27. Kriging interpolation of “detrended” data ‘Kriging’ condition = ‘spatialy’ homogeneous data Use relation between land use indicator and AQ statistics to “detrend” monitoring data: Remove local character of sampling values

  28. RIO-corine methodology • Detrend sampling values • Interpolate detrended values with Ordinary Kriging • Determine local b-value • Get corresponding trend shift (DC) • Add DC to interpolation result Correlation <-> distance

  29. Valdidation – “leaving-one-out” Compare with standard IDW and OK

  30. Valdidation – using “independent” measurements R² = 0.90MAE = 2.9 µg/m³ RMS = 4.3 µg/m³ Average observations : 30.6 µg/m³ Average RIO-c interpolation : 31.5 µg/m³

  31. Annual mean PM10 concentrations 2006 RIO-corine Ordinary Kriging

  32. Annual average NO2 concentrations 2002 OK RIO

  33. RIO-corine : further developments (1) NO2 - 4x4 km NO2 - 1x1 km

  34. RIO-corine : further developments (2) New proxy : AOD (aerosol optical Depth) ? Total Column AOD 2006 Source : Modis Terra satelite, 2006

  35. RIO-corine : more info “Spatial interpolation of air pollution measurements using CORINE  landcover data ” Janssen Stijna, Dumont Gerwinb, Fierens Fransb, Mensink Clemensa aFlemish Institute for Technological Research (VITO),Boeretang 200, B-2400 Mol, Belgium bBelgian Interregional Cell Environment Agency(IRCEL), Kunstlaan 10-11, B-1210 Brussels, Belgium Atmospheric Environment 42/20 (2008) 4884-4903

  36. Contents Choice of PM-Measurement locations Calibration of PM-Measurements - equipment Future technical development in the next 2-3 years Data acquisition - Handling of PM-data Spatial Interpolation of PM-point data Forecast Modelling (deterministic / statistical models).

  37. Goal of Air Quality forecasts ? Polluant : PM10 Plan : 1 niveau Flanders Brussels Wallonia Polluants : PM10 et NO2 Plan : 3 niveaux Polluant : PM10 Plan : 3 niveaux • Information of the public (see ozone EU info/alert thresholds) • Activation winter SMOG action plans (FORECASTED PM10 > 70 µg/m³, for two consecutive days)

  38. Two different types of models • Deterministicmodels • Complex input : meteo, emissions, geograficalinformation, fysico-chemical processes • Long CPU -> CHIMERE (forecasts) / BelEUROS (emission scenario’s) • Statistical or neural-network models • Simple input : database with measurements, some simple forecasted meteo parameters • Short CPU (minutes) ->SMOGSTOP (Ozone) / OVL (PM10, NO2)

  39. CHIMERE : simple schematic overview ExampleTemperature NOx emissionscombustion

  40. CHIMERE – Example (1) Forecast for 21/6/2005 Observations 21/6/2005

  41. CHIMERE – Example (2)

  42. OVL : schematically • PM10 measurements day-1 • Meteo forecasts Input: Neural Network Process: Output : PM10 daily mean day0, +1, +2, +3 and +4

  43. OVL : most important meteo-input parameter Temperature Inversion Boundary Layer Height Low windspeeds

  44. OVL : PM10 – winter/spring 2005forecast day +1 R=0.7 Antwerp (monitoring station 42R801)

  45. OVL : more info “A neural network forecast for daily average PM10 concentrations in Belgium” Hooyberghs Jefa, Mensink Clemensa, Dumont Gerwinb, Fierens Fransb, Brasseur Olivierc aFlemish Institute for Technological Research (VITO),Boeretang 200, B-2400 Mol, Belgium bInterregional Cell for the Environment (IRCEL), Kunstlaan 10-11, B-1210 Brussels, Belgium cRoyal Meteorological Institute (RMI), Ringlaan 3, B-1180 Brussels, Belgium Atmospheric Environment 39/18 (2005) 3279-3289

  46. Dank voor uw aandacht !Je vous remercie de votre attention !Wir danken Ihnen für Ihre Aufmerksamkeit !Thank you for your attention ! More info :www.ircel.bewww.vmm.be

More Related