1 / 19

CSCE 212 Chapter 8 Storage, Networks, and Other Peripherals

CSCE 212 Chapter 8 Storage, Networks, and Other Peripherals. Instructor: Jason D. Bakos. Magnetic Disk Storage: Terminology. Magnetic disk storage is nonvolatile 1-4 platters, 2 recordable surfaces each 5400 – 15,000 RPM 10,000 – 50,000 tracks per surface Each track has 100 to 500 sectors

sienna
Download Presentation

CSCE 212 Chapter 8 Storage, Networks, and Other Peripherals

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CSCE 212Chapter 8Storage, Networks, and Other Peripherals Instructor: Jason D. Bakos

  2. Magnetic Disk Storage: Terminology • Magnetic disk storage is nonvolatile • 1-4 platters, 2 recordable surfaces each • 5400 – 15,000 RPM • 10,000 – 50,000 tracks per surface • Each track has 100 to 500 sectors • Sectors store 512 bytes (smallest unit read or written) • Cylinder: all the tracks currently under the heads

  3. Accessing Data • To read: • Seek to the track • Ave. seek times advertized as 3 ms to 14 ms but usually much better due to locality and OS • Rotate to the sector • On average, need to go ½ around the track • Transfer data • 30 – 40 MB/sec from disk, 320 MB/sec from cache • Controller time / overhead • ADAT = seek time + rotational latency + transfer time + controller time

  4. Reliability • Mean time to failure (MTTF) • Mean time to repair (MTTR) • Mean time between failures (MTTF + MTTR) • Availability = MTTF / (MTTF + MTTR) • Fault: failure of a component • To increase MTTF: • Fault avoidance • Fault tolerance • Fault forecasting

  5. RAID • Redundant Arrays of Inexpensive Disks • Advantages: • parallelism • cost • floor space (smaller disks have higher density) • Disadvantage: • adding disks to the array increases the likelihood of individual disk failures • Solution: • add data redundancy to recover from disk failures • small disks are inexpensive, so this reliability is less expensive relative to buying fewer, larger disks

  6. RAID • RAID 0 • No redundancy • Stripe data across disks • Appears as one disk • RAID 1 • Mirroring • Highest cost • RAID 2 • Error control codes • No longer used

  7. RAID • RAID 3 • Bit-interleaved parity • Add one parity disk for each protection group • All disks must be accessed to determine missing data • Writes access all disks for striping, then recalculation of parity • Example: • 1 0 1 0 • 1 X 1 0 • X=1 xor 1 xor 0

  8. RAID • RAID 4 • Block interleaved parity • Stripe blocks instead of bits • Small writes only need to access one data disk and update parity • Only flip parity bits that correspond to changed data bits • Example: • 0011 1010 1101 0100 • 0011 XXXX 1101 0100 • XXXX=0011 xor 1101 xor 0100

  9. RAID • RAID 5 • Distributed block-interleaved parity • In RAID 4, the parity disk is bottleneck • Solution: alternate parity blocks

  10. RAID • RAID 6 • P + Q Redundancy • Add another check disk to be able to recover from two errors • RAID 1 and 5 are most popular • RAID weakness: • Assumes disk failures are not correlated

  11. Busses • Shared communication link • Advantages: • Inexpensive, simple, extendible • Disadvantages: • Capacity is shared, contention creates bottleneck • Not scalable • Length and signaling rate limitations (skew, noise) Device 1 Device 2 Device 3

  12. Model Computer System

  13. Busses • Typical bus: • data lines • DataIn, DataOut, Address • control lines • Bus request, what type of transfer • Busses are either: • synchonous • includes shared clock signal as a control signal • devices communicate with a protocol that is relative to the clock • example: send address in cycle 1, data is valid in cycle 4 • used in fast, short-haul busses • asynchronous • not clocked or synchronized • requires handshaking protocol

  14. Bus Types ReadReq asynchronous (peripheral bus) Data Ack DataRdy Clock synchronous (system bus) Read Data

  15. Model Computer System

  16. Model Computer System • Example computer system: • northbridge: fast interconnect for memory and video • southbridge: slower interconnect for I/O devices

  17. I/O • I/O Schemes: • Memory-mapped I/O • Contolled by CPU • I/O devices act as segments of memory • CPU reads and writes “registers” on the I/O device • Example: status register (done, error), data register • DMA (Direct Memory Access) • Controlled by I/O device • DMA controller transfers data directly between I/O device and memory • DMA controller can become a bus master • DMA controller is initialized by the processor and I/O device • Polling • CPU regularly checks the status of an I/O device • Interrupts • I/O device forces the CPU into the operating system to service an I/O device request • Interrupts have priority (for simultaneous interrupts and preemption)

  18. I/O Performance Measures • Transaction Processing • Database applications (i.e. banking systems) • Mostly concerned with I/O rate and response time • Benchmarks created by Transaction Processing Council (TPC) • TPC-C: complex queries • TPC-H: ad hoc queries • TPC-R: standard queries (preknowledge) • TPC-W: web-based simulates web queries • File System • MakeDir, Copy, ScanDir, ReadAll, Make • SPECFS (NFS performance) • Web I/O • SPECWeb (web server benchmark) • I/O performance estimation: simulation or queueing theory

  19. Example Problem • CPU can sustain 3 billion instructions per second and averages 100,000 instructions in the OS per I/O operation • Memory backplane bus capable of sustaining a transfer rate of 1000 MB/s • SCSI Ultra320 controllers with a transfer rate of 320 MB/s and accomodating up to 7 disks • Disk drives with a read/write bandwidth of 75 MB/s and an average seek plus rotational latency of 6 ms • If the workload consists of 64 KB sequential reads and the user program requires 200,000 instructions per I/O operation, what’s the maximum I/O rate and the number of disks and SCSI controllers needed (ignoring disk conflicts)?