1 / 20

Light higgs decay in SUSY cascade - Status report

Light higgs decay in SUSY cascade - Status report. Introduction Trigger efficiency B tagging Jet calibration Invariant mass reconstruction Likelihood fit Conclusion . Filip Moortgat (CERN) Alain Romeyer (Mons - Belgium). LSP MET. Introduction. B tagging.

sinead
Download Presentation

Light higgs decay in SUSY cascade - Status report

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Light higgs decay in SUSY cascade - Status report • Introduction • Trigger efficiency • B tagging • Jet calibration • Invariant mass reconstruction • Likelihood fit • Conclusion Filip Moortgat (CERN) Alain Romeyer (Mons - Belgium) Alain Romeyer - January 2005

  2. LSP MET Introduction B tagging Benchmark point LM5 Tan b = 10 AO = 0 µ > 0 M1/2 = 360 GeV M0 = 230 GeV h0 b MSUGRA 5 parameters : m0, m1/2,A, tan b, sign(µ) S. Abdullin – L. Pape Update II of the new MSUGRA test points proposal Signature : Alain Romeyer - January 2005

  3. Simulated events • Production of signal events and pile-up • Signal events : all SUSY channel (easier for later event reweighting) • ~20% contains our decay chain • Digitisation : merge pile-up and signal • official 100 000 evts production at CERNavailable • our reconstruction strategy launched on digis • First results Isajet 7.69 + Pythia 6220 + CMKIN generator FULL SIMULATION CHAIN simulation OSCAR2_4_6 digitisation ORCA7_6_1 Alain Romeyer - January 2005

  4. « Reconstruction » strategy • ORCA_8_6_1 Reconstruction Simulatedevents • II - Jet Reconstruction : • Iterative Cone Algo. • cone size : 0.5 • tower Et thr. : 0.5 GeV • seed Et thr. : 1 GeV I – L1 +HLT Efficiency ? Jet sel. Pt > 10 GeV • III - B tagging : • By Track Counting • Number of tracks above minimum significance : 2 • Analysis • event selection • IV - b ̅b inv mass reco. • MET : • MET from EcalHcalTower Alain Romeyer - January 2005

  5. Trigger efficiency • L1 : 99.9 % - HLT : 96 % Low Lumi. Non cumulative Trigger !!! ~ all events !!! Caveat : ~ same efficiency for SUSY bkg. Alain Romeyer - January 2005

  6. Btagging Track Counting Algo. (default setting) Global efficiency : 49.5 % Global inefficiency : 9.4 % Need to be optimised Filip Nhiggs = Nhiggs after HLT * ( Btag Eff. )² ~ 4700 evts Alain Romeyer - January 2005

  7. Efficiency / inefficiency Alain Romeyer - January 2005

  8. Efficiency / inefficiency… Alain Romeyer - January 2005

  9. Select b jets from h0 Select only b jets coming from h0 decay (from parton content in a 0.3 cone) No jet energy calibration Alain Romeyer - January 2005

  10. Jet reconstruction accuracy Alain Romeyer - January 2005

  11. Jet calibration • Jet calibration method following CMS-note 1999/066 • Association between rec. Jets and generated partons before hadro. (cone < 0.3) • 2 types of jets : b jets and other • Etruejet = sum(Equarks,gluons) • Correction Factor C = Etruejets / Erecjets • Fit of the correction factor surface in the E vs || plane : Alain Romeyer - January 2005

  12. E correction for b jets Alain Romeyer - January 2005

  13. E correction for non b jets Same operation is done with the jet momentum Alain Romeyer - January 2005

  14. Impact on Minv Select only b jets coming from h0 decay Calibrated jets Alain Romeyer - January 2005

  15. Impact on jet reco. accuracy Alain Romeyer - January 2005

  16. Invariant mass (no cuts) Alain Romeyer - January 2005

  17. Likelihood fit NormalisedGaussian Extract from background fit Fraction of signal • Follow the Z’  µµ strategy (CMS AN 2004/018) • Unbinned method • No constraints on the absolute background level only on the background shape • 3 parameters : mh, s and Alain Romeyer - January 2005

  18. Fit result (full stat) Unbinned fit Binned only when plotted Alain Romeyer - January 2005

  19. Various running time 50 000 evts – S = 10.9 100 000 evts – S = 14.1 25 000 evts – S = 7.95 15 000 evts – S = 5.8 Alain Romeyer - January 2005

  20. Conclusion • For the first time the full analysis chain is working • higgs peak visible with significance above 5 • ~15000 evts (~ 40 days of understood data) • Future : • Include SM background • Improve S/B ratio (cuts, b tagging optimisation…) • Reduce the width of the invariant mass • Run the code on the Zbb sample for cross check and optimisation of the reconstruction strategy • Fast simulation (FAMOS) in order to explore the SUSY parameter phase space • Contour plot for the CMS reach Alain Romeyer - January 2005

More Related