An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CP2000 Introduction

  2. Agenda • CP2000 Introduction • CP2000 Top 10 Features • CP2000 Field Application

  3. CP2000 Introduction • For Fans/Pumps/HVAC Drive applications. • HVAC: Heater, Ventilating, Air Conditioner. • V/F control、SVC (sensorless vector control) • PID control and sleep/wake up function • Multi-pumps, circulation pumps control • Fire mode + BYPASS function • PLC(10K step) + Real Time Clock • VFD-soft link and LCD TP editor • Built-in BACnet • LCD keypad user friendly interface

  4. From the relations illustrated above, we can reduce the running frequency of the motor according to the load. EX: When the motor’s running speed is reduced from 60Hz to 50Hz by mains electricity… Theoretical Value: (50*50*50)/(60*60*60)=0.58 (Only 58% of the electricity is required.) Energy saving on HVAC

  5. V/F,SVC TN Curve V/F SVC T-N(Nt/m) T-N(Nt/m) rpm rpm

  6. Pump and Fan Control *Booster pumps of municipal water supply systems *Automatic level control of reservoirs Master Motor Regulated speed Mains Supply ~ *Pumps and fans of waste water treatment plants R S T FWD/STOP U V W FWD AuxiliaryM1 Run/Maintenance Motor 1 Motor 2 Motor 3 Constant speed Constant speed Constant speed MI1 Output Frequency AuxiliaryM2 Run/Maintenance Hz AFM MI2 AuxiliaryM3 Run/Maintenance MI3 ~ ~ ~ RA1 RA2 RA3 DCM *HVAC systems *Cooling tower fan drivers Pressure RA1 M1 control Transducer RC1 PID feedback RA2 *Combustion air and exhaust gas fans of power plants M2 control PT RC2 function select RA3 M3 control RC3

  7. CP2000 Power Capability • 460V 3 Phase 0.75kW~400kW • Models under 37kW with built-in EMI filter for: VFD007CP4EA-21, VFD015CP4EA-21, VFD022CP4EA-21, VFD037CP4EA-21, VFD040CP4EA-21, VFD055CP4EA-21, VFD075CP4EA-21, VFD110CP4EA-21, VFD150CP4EA-21, VFD185CP4EA-21, VFD220CP4EA-21, VFD300CP4EA-21, VFD370CP4EA-21 • Models under 37kW with built-in braking unit • 45kw~400kW with built-in DC reactor,optional for EMI filter、 optional for braking unit • 230V 3 phase 0.75kW~90kW • Models under 30kW with built-in braking unit • Models above 37kW with built-in DC reactor • Optional EMI filter. LCD BUILT-IN~ C2000 same Platform

  8. CP2000 Model name

  9. Ordering information

  10. FRAME size comparison Frame E 125~150HP Frame AFrame BFrame CFrame D 1~7.5HP10~20HP 25~40HP50~100HP

  11. CP2000 TOP Features Control method:V/F control & SVC control、PID control and sleep/wake up function、 Multi-pumps control 、FIRE MODE、PLC、real time clock. Optional cards : communication cards & I/O extension card,CANopen(DS-402) Built-in : RS-485, MODBUS and BACnet User designed PLC program for sequential control Built-in protocol BACnet MODBUS PLC(10K step) D24A R6AA COP01 ProfiBUS Ethernet IP MODBUS TCP DeviceNet I/O card Relay card CANopen cards

  12. CP2000 TOP 1 Modular design maintain free Plug-in/out terminal Removable Fan

  13. CP2000 TOP 2 Designed for environment adaption • Robust design • PCB Coating treatment, assure the reliable operation in the harsh environment • Suppress harmonic: Built-in RFI filter; Models above Frame D have built-in DC reactor. • Comply with EN61800-3 • *AFE2000, DC reactor, AC reactor, and EMI filter are options for the models without built-in DC reactor or EMI filter.

  14. CP2000 TOP 3 Isolated Control PWB • Control PWB no touch with heat sink • Heat sink is isolated with control PWB system for preventing CP2000 from damaging and environmental pollution

  15. CP2000 TOP 3 Flange mounting: • Put all heat generated from inverter out. • Isolating all the dust from the environment.

  16. CP2000 TOP 4 LCD Keypad IP56 Proof level Plug & Play

  17. CP2000 TOP 4 LCD Keypad Features • Quick setting for user common usage, easy and fast to install. • Multi-row display, Menu free, user friendly operation interface. • Monitoring F (Freq.)、H (output Freq.)、U (User definition) synchronously. • CAN、PLC and HAND/OFF/AUTO status display • User defined parameter management • Real time clock • Error log with timing record • Multi-language

  18. CP2000 TOP 4 • PLC program, Drive Parameter Copy/Backup/Restore to VFD_soft or CP2000. • TP Editor for USER defining the display on the screen of keypad. • VFD_soft and LCD panel for bi-direction edit function. • LCD panel portable, plug & play.

  19. VFD-soft & TP Editor

  20. CP2000 TOP 5 • Built-in PLC (10K step): It can be used with the built-in real time clock for special multi-pumps control.

  21. CP2000 TOP 6 Most common used, various high speed network • Built-in BACnet

  22. CP2000 Options List

  23. CP2000 TOP 7 Multi-pumps control 1: Fixed Time Circulation (by time) 2: Fixed amount circulation (by PID) 3: Fixed amount control (by PID) 4: Fixed Time Circulation+ Fixed amount circulation 5: Fixed Time Circulation+ Fixed amount control Fixed Time Circulation (Max: 8 pumps)

  24. Multi-pumps control Fixed amount circulation (Max: 4 pumps) Fixed amount control (Max: 8 pumps)

  25. Fire mode + bypass function CP2000 TOP 8 • Application: ventilating of building, tunnel, subway, etc. • During fire mode the drive is forced operation. • BYPASS mode is selected to AC power (with ac Mains Bypass breaker). • Exhausting smoke until drive failure or AC power shut down.

  26. CP2000 TOP 9 • Flying start function lets high inertial load situation can run smoothly in start without error happened. (No need to stop the motor) • Momentary power off (within 5s on LV), the speed searching function can make the motor continue running without stopping the motor to save start time. start speed tracking Flying start to smooth going

  27. CP2000 TOP 10 • Skip frequency function avoids the motor vibration at a specific frequency band and protects the equipment. It offers 3 zones for use.

  28. CP2000 TOP 10 • DEB (Deceleration Energy Backup) This function allows the AC motor drive decelerates to stop after power loss. When the momentary power loss occurs, this function can be used for the motor to decelerate to 0 speed with deceleration stop method. When the power is on again, motor will run again after DEB return time.

  29. VFD-CP2000 position market Variable Torque Normal usage Machinery field torque control Servo characteristic VL FOC VE VJ B FELXIABLE VFD-CP2000 F E S/M ECONOMICAL EL APPLICATION CASE FANS PUMPS HAVC V/F FEEDER EXTRUDER ELEVATOR CRANS WINDER TENSION CONTROL POSITION CONTROL

  30. CP2000 FIELD APPLICATIONS Build Automation (HVAC) TOWER FANS COOLING PUMP BLOWER COOLING SYSTEM

  31. HVAC

  32. HVAC Drive power segment Applications of public works

  33. Industrial tower blower Main Application: V/F control, energy saving

  34. Exhausted gas treatment system Main application :V/F variable torque control

  35. Air Treatment application Main application :V/F variable torque control

  36. Tunnel Blower Main application :V/F variable torque control

  37. Water Treatment Main application :V/F variable torque control

  38. Thanks