1 / 31

Problems with the uncertainty budget of half-life measurements

Problems with the uncertainty budget of half-life measurements. S. Pommé. Half-life Measurements. Half-life determination by following the decay of a radioactive source The problem of data discrepancy; examples Autocorrelation causes underestimation of the uncertainty

skule
Download Presentation

Problems with the uncertainty budget of half-life measurements

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Problems with the uncertainty budget of half-life measurements S. Pommé

  2. Half-life Measurements • Half-life determination by following the decay of a radioactive source • The problem of data discrepancy; examples • Autocorrelation causes underestimation of the uncertainty • Example: the decay of Fe-55 230th ACS NM - T1/2

  3. Half-life of 109Cd a selection of the ‘best’ data 230th ACS NM - T1/2

  4. Half-life of 134Cs 230th ACS NM - T1/2

  5. Half-life of 54Mn a selection of the ‘best’ data 230th ACS NM - T1/2

  6. Half-life of 55Fe 1020 1010 1000 Days 990 980 970 Morel Hoppes Schötzig Lagoutine Van Ammel Karmalitsyn Houtermans a selection of the ‘best’ data 230th ACS NM - T1/2

  7. Why are uncertainties underestimated? It 's the MODELING, stu**d! ** by analogy with ‘It’s the economy, stupid!’ by James Carvil, advisor of Bill Clinton in the elections of 1992 230th ACS NM - T1/2

  8. Example: decay of 55Fe measured activity fitted decay curve T1/2=1005.0 d ± 1.4d 230th ACS NM - T1/2

  9. Procedure ‘uncertainty from fit’ • calculate the c2–value, ensuring that it assumes its expectation value = the number of degrees of freedom • adjust the half-life so that c2 increases by a value of one • adopt as the standard deviation the square root of the amount by which the half-life was varied Bevington, P.R. Data Reduction and Error Analysis for the Physical Sciences; McGraw-Hill Book Company, New York, USA, 1969 230th ACS NM - T1/2

  10. Residuals 55Feadd uncertainty component of 0.0175% c2/n=3.5 c2/n=1.0 230th ACS NM - T1/2

  11. Check of distribution of residuals BEFORE introducing extrauncertainty component AFTER c2/n=3.5 c2/n=1.0 230th ACS NM - T1/2

  12. Half-life and uncertainty from least-squares fit => fit underestimates uncertainty! 230th ACS NM - T1/2

  13. Why? least-squares fit requires RANDOMNESS 230th ACS NM - T1/2

  14. Residuals 55Fe: blow up uncertainty only including counting statistics => does not fully account for spread of data 230th ACS NM - T1/2

  15. Autocorrelated data are not random autocorrelation plot of the residuals 230th ACS NM - T1/2

  16. Alternative Procedure • Subdivide instabilities according to frequency (low, medium, high) • Apply new (simplified) uncertainty formula: n= the number of occurances of the effect n=1 for medium and low frequencies • Add all components as square sum 230th ACS NM - T1/2

  17. Subdivide instabilities according to frequency noise, counting statistics, …=> random effects geometrical reproducibility, ‘seasonal’ effects,short-lived impurity, … dead time, detector/source degradation,background subtraction, … 230th ACS NM - T1/2

  18. T1/2 from combination of all data T1/2 230th ACS NM - T1/2

  19. Realistic uncertainty 230th ACS NM - T1/2

  20. Some examples from literature 230th ACS NM - T1/2

  21. Residuals Ba-133 data scatter exceeds uncertainty => unidentified HIGH FREQUENCY component NIM A390 (1997) 267-273 230th ACS NM - T1/2

  22. Residuals Cs-134 MEDIUM FREQUENCY instability => fit underestimates uncertainty NIM A390 (1997) 267-273 230th ACS NM - T1/2

  23. Residuals Ce-144 sign of LOW FREQUENCY deviation => fit tends to hide it NIM A390 (1997) 267-273 230th ACS NM - T1/2

  24. Residuals Y-88 only a few measurement data => LACK OF INFORMATION NIM A390 (1997) 267-273 230th ACS NM - T1/2

  25. Residuals Cd-109 OVERESTIMATION of measurement uncertainty => overestimates uncertainty of half-life? NIM A390 (1997) 267-273 230th ACS NM - T1/2

  26. Residuals 99Tcm systematic deviation for short times electrometer range switching ARI 60 (2004) 317-323 230th ACS NM - T1/2

  27. Conclusions • perform many measurements with good statistical accuracy and carefully study the randomness of the residuals • identify and quantify medium and low frequency instabilities separately and apply a conservative propagation factor to T1/2 • report in sufficient detail, for traceability Half-life measurements are NOT EASY ! 230th ACS NM - T1/2

  28. Half-life of 93mNb 230th ACS NM - T1/2

  29. Half-life of 152Eu a selection of the ‘best’ data 230th ACS NM - T1/2

  30. Residuals Co-57 decreasing accuracy with time => extension of experiment becomes ineffective NIM A390 (1997) 267-273 230th ACS NM - T1/2

  31. Residuals Ba-133 and Eu-152 ‘independent’ measurements showing correlations => ‘medium term’ detector instability NIM A390 (1997) 267-273 230th ACS NM - T1/2

More Related