How is it different – UNIVERSAL SYSTEM

How is it different – UNIVERSAL SYSTEM. Plug and Play™ Universal System. Overview Features and Benefits Competitive Landscape Compatibility with Previous Products Key Messages Supporting Collateral Promotional Timeline. Plug and Play™ Universal System: An Overview.

solada
Download Presentation

How is it different – UNIVERSAL SYSTEM

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. How is it different – UNIVERSAL SYSTEM

  2. Plug and Play™ Universal System • Overview • Features and Benefits • Competitive Landscape • Compatibility with Previous Products • Key Messages • Supporting Collateral • Promotional Timeline

  3. Plug and Play™ Universal System:An Overview • What is polarity management? • Maintaining proper transmit-to-receiver continuity throughout a system • How does Plug and Play™ Universal System do it? • Uses a patented wiring solution in the modules so that no matter how many modules, harnesses, trunks or extender trunks are used or where they are placed, fiber polarity is maintained • Why is polarity management important? • Improperly placed or installed polarity components can result in system failure • Planning for polarity components during design and installation adds time and complexity • Also adds complexity to inventory • When the time comes for moves, changes and adds, polarity may have to be reconfigured all over again

  4. Rx Tx Tx Rx Tx Rx Rx Tx Blue fibre on the left (Position 1) Blue fibre on the right (Position 2) Polarity Basics – Transmit Goes to Receive • Reverse Fibre Positioning – • Fibres are terminated into the connector in a different order on each end (Blue/Orange on one end and Orange/Blue on the other end) • With this schematic, intention is to transmit top fibre to top fibre and bottom fibre to bottom fibre (pair wise) • Standard for jumpers • Maintains transceiver continuity regardless of number of links

  5. How is it different – UNIVERSAL WIRING Standards Activity TIA Standards Activity — Guidelines for Maintaining Polarity Using Array Connectors METHOD C “A” “B” Module U-Mod METHOD B Pair-Wise Flips in the Trunk METHOD A “A” “B” Jumper

  6. Pros One module Easy reconfiguration; allows concatenation Accepts UniCam MTP Cons Customer sets polarity Special jumper purchase or use un-duplexable jumpers Requires special components for parallel optics Testing issues Pros Standard patch cords Accepts UniCam MTP Allows concatenation Cons Installer sets polarity Not easy to move modules around Requires advance planning for modules Difficult to reconfigure network Limited suppliers Requires special components for parallel optics Plug and Play™ Universal System:An Overview – Competitive Landscape A-B Patch Cords A-B Modules

  7. Plug and Play™ Universal System:An Overview – Competitive Landscape • Pros • Manufacturer sets polarity • One module, standard patch cord • Standard components; key up/key down MTP adapter • Single-mode available • Cons • Monitor number of trunks in a channel • Requires special jumper for parallel optics • Limited UniCam MTP capability Pair-wise Flips in the Trunk

  8. Systimax - InstaPATCH Plus

  9. MTP End Duplex Connector end TX/RX #1 How is it different – Classic Wiring • Module Straight Wiring • Single fibre connectors are plugged consecutively (1, 2, 3, 4, 5, 6, …..)

  10. How is it different – Classic Wiring Pair-wise Flips in the Trunk • Trunk is Made KEY-UP to KEY-DOWN • Trunk has Ribbon Pairs flipped • Trunk is non-pinned on both end • Modules are identical with straight wiring and pinned MTPs • All Standard MTPs Mate Key up/Key down Key Down Key Up Key Up Key Down

  11. Classic Method with Pair-wise Flips

  12. Classic Method with Pair-wise Flips

  13. How is it different – UNIVERSAL WIRING Features • Module Universal Wiring • Single fibre connectors are plugged in the order of 1, 12, 2, 11, 3, 10, 4, 9, 5, 8, 6, 7 MTP End 6 7 5 8 4 9 3 10 2 11 1 12 Duplex Connector End TX/RX #1

  14. How is it different – UNIVERSAL TRUNKS • Trunk is Made KEY-UP to KEY-UP • Trunk MTPs are all non-pinned • Modules are identical with Universal wiring and Standard pinned MTPs • All Standard MTPs Mate Key up/Key down • Can accommodate SM Angled MTPs Key Down Key Up Key Up Key Down

  15. How is it different – UNIVERSAL WIRING Path Map

  16. How is it different – UNIVERSAL WIRING Path Map

  17. How is it different – UNIVERSAL WIRING Path Map

  18. How is it different – EXTENDER TRUNKS • Extender Trunk is pinned on one end and non-pinned on the other • All MTPs Mate Key up/Key down • Universal Trunks are normally high fiber count and route between floors or between large zones of the Data Center. • Extender Trunks are low fiber counts that branch off into different areas of the larger zones. Key Down Key Up Key Up Key Down Key Up Key Down

  19. How is it different – UNIVERSAL WIRING Features • Plug and Play Universal System: • “U” and “U with LL” on the top front face of the module • “U” = Universal • “U LL” = Universal Low Loss • Orange label (Universal) • Green label (Universal Low-Loss) • Color Coded Labels on both the module and trunk • Plug and Play Classic System: • White label • Color Coded Labels on both the module and trunk

  20. Plug and Play™ Universal System:An Overview – Compatibility with Previous Product • Component-to-component, the Plug and Play™ Universal System and the Plug and Play™ Classic System are not compatible • Universal: Manages polarity in the module • Classic: Manages polarity in the trunk • However, projects that have previously installed Classic can take advantage of Universal for extensions to/adding a link • This can be done via a cross connect • Plug and Play Universal System is our lead product and our standard Plug and Play offering • However, the Classic system will remain available (though it will not be actively promoted or very visible) • New customers and existing customers with new projects should be encouraged to use the Universal system • Customers working on existing Classic installations will likely need to continue with the Classic system

  21. How is it different – UNIVERSAL WIRINGBenefits • Two or more MTP trunks can be easily linked together. High fiber count trunks can be routed to an intermediate distribution area where smaller fiber count trunks are interconnected and distributed to zone, station or cabinet areas. • Provides a simple migration path between 2-fiber and parallel applications. • No special polarity components or polarity concerns during link configuration and re-configuration • Modules and harnesses are wired the same to simplify system assembly. Module-to-module, module-to-harness, or harness-to-harness all provide the same fiber paths. • Modular system enables fast and simple networking moves, changes and adds with correct fiber polarity guaranteed • Avoids polarity problems caused by incorrect placement of fiber pair-wise flipped modules or jumpers in the network. • System length is expandable by using Universal Extender Trunks without impacting transmit/receive polarity

  22. Plug and Play™ Universal System:An Overview – Competitive Landscape • Who does what? • Universal Wiring* • CCS Plug and Play™ Universal System • InstaPATCH Plus • Systimax • A-B Patch Cords • Nordx, Panduit, small CAHs • Pair-Wise Flips in the Trunk • CCS Plug and Play™ Classic System, Tyco, Emerson, ComputerCrafts, DC Connections, CompuLink • A-B Modules* • Ortronics, small CAHs *Not in the proposed standard

  23. Plug and Play™ Universal System:Supporting Collateral • Plug and Play™ Universal System Line Card (LAN-668) • Describes components: trunks, extender trunks, modules, harnesses, and patch cords • Plug and Play Universal System Spec Sheet (LAN-664) • Plug and Play Universal System Part Number Reference Sheet (LAN-666) • Provides part numbers for trunks, extender trunks, modules, harnesses, patch cords and rack mountable patch panels • Preferred items only • Data Center Pretium Line Card (LAN-550) • Describes Plug and Play System, cable assemblies, cables, connectors, hardware, services and support (not just unique to Universal) • Plug and Play Compatibility Checklist (for internal use only, available in .pdf in the sales library) • Provides support for working with customers on determining which Plug and Play System they are using/should be using

  24. Fiberprotrusion LOW LOSS – NEW POLISHING PROCESS Fibers protrude 10 um evenly above ferrule end face. CCS patented process MTP connectors have a low-loss option available. The low-loss solution minimizes the db loss of a module or a harness. Typically, losses in the module or harness are rated at a maximum of 1.3 db. With the low loss module or harness losses will be reduced to a maximum of 0.75 db. This results in an enhanced performance module or harness due to new precision components in the connector. The polishing process of the fiber in the ferrule of the connector gives you better performance and allows better db performance down to 0.75 db.

  25. LOW LOSS – NEW POLISHING PROCESS BENEFITS • Connector Pair – Low Loss (Max 0.5 dB) MTP Matings • Module Loss (Max 0.75 dB) SC and LC Multimode Pretium 300 50um Modules • Reduced insertion loss => More connections per link • Reduced insertion loss => Longer link length achievable • Reduced insertion loss => Increased system margin

  26. Low Loss Polishing Process Components • Low Loss is a SYSTEM • Plug & Play Systems utilizing Low Loss MTP are comprised of BOTH: • A MTP to MTP LOW LOSS TRUNK with MTP connectors that have the new polishing process • SC or LC Multimode Pretium 300 LOW LOSS Modules with MTP connectors that have the new polishing process • The 10um fiber protrusion allows the two components to work together to provide a MTP to MTP mating with a PHYSICAL CONTACT.

  27. How is it different – NEW POLISHING PROCESS BENEFITS WHY IS THIS A GOOD THING

  28. LOW LOSS – NEW POLISHING PROCESS BENEFITS • Low loss components become very important in high bandwidth communications protocols, where link loss budgets are relatively low. Example: • Use de-rating tables to answer the following: • Consider a 120 meter link running 10 GbE over laser Laser-Optimized 50/125 um-300 fiber, where — Cable attenuation = 3.0 dB/km — EMB = 2000 MHz-km. • How many standard Plug & Play modules, each having 1.3 dB max loss, can be used in the link? — Answer: 4 modules can be used. Max channel insertion loss will be (0.12 km x 3.0 dB/km) + (4 x 1.3 dB) = 5.56 dB. • How many low loss Plug & Play modules, each having 0.75 dB max loss, can be used in the link? — Answer: 7 modules can be used. Max channel insertion loss will be (0.12 km x 3.0 dB/km) + (7 x 0.75 dB) = 5.61 dB.

  29. New Low Loss Price = Standard Pricing 10% Premium over std. pricing Part numbers and pricing – LOW LOSS PnP MTP connector codes change for the low loss version. Low Loss Trunk Example: A757524S88AAU100F Low Loss Module Example: CCH-UM24-05-93S Low Loss only available in Pretium 300 LC and SC modules Grip + Cable + Furcation + Labels + Packaging + Conn. Install = Price

  30. Part Numbers STANDARD Classic Trunk Ex. A696972S8800100F Universal Trunk Ex. A696972S88AAU100F Universal Extender Trunk Ex. A706972S88AAX100F Classic Module Ex. CCH-CM24-05-69S Classic Reduced Depth Ex. CCH-RM24-05-70S Universal Module (Reduced Depth) Ex. CCH-UM24-05-70S Legacy Harness Ex. HPP057012SJ1OA10F Universal Harness Ex.H930512SJ1-LZ010F LOW LOSS Classic Trunk Ex. A757572S8800100F Universal Trunk Ex. A757572S88AAU100F Universal Extender Trunk Ex. A937572S88AAX100F Classic Module Ex. CCH-CM24-05-93S Classic Reduced Depth Ex. CCH-RM24-05-93S Universal Module Ex. CCH-UM24-05-93S Legacy Harness Ex. HPP059312SJ1OA10F Universal Harness Ex.H930512SJ1-LZ010F