Card 1a

Card 1a. Discrete Ordinate Multiple Scattering Algorithm: Issacs Two-Stream Algorithm (fast but less accurate) Multiple Scattering Algorithm. Number of Streams to be used by DISORT – the higher the number the longer the run time 8 is a recommended value for most applications.

sook
Download Presentation

Card 1a

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Card 1a

  2. Discrete Ordinate Multiple Scattering Algorithm: Issacs Two-Stream Algorithm (fast but less accurate) Multiple Scattering Algorithm

  3. Number of Streams to be used by DISORT – the higher the number the longer the run time 8 is a recommended value for most applications

  4. Option to read solar irradiances from a file: Use default spectral solar irradiances Read from file (requires ISUN input)

  5. Full Width Half Max FWHM of the triangular scanning function used to smooth the top of the atmosphere (TOA) solar irradiances (wavenumbers)

  6. CO2 mixing ratio in ppmv: Inputs of zero or leaving it blank defaults to an input of 330 ppmv Recommended value is closer to 365 ppmv

  7. Vertical Water Vapor Column: If blank or zero the default is used If a leading character of “g” is used before the number the units will be in g/cm2 (e.g., g 2 ) If a leading character of “a” is used the before the number the units will be in atm-cm Otherwise a numerical input will be considered a scaling factor applied to default water vapor column

  8. Vertical Ozone Column: If blank or zero the default is used If a leading character of “g” is used before the number the units will be in g/cm2 (e.g., g 2 ) If a leading character of “a” is used the before the number the units will be in atm-cm

  9. Solar Radiance Data File Option: Use Default Solar Radiance File Read in a Solar Radiance File

  10. Band Model Option: Use Default Band Model Read in Band Model File

  11. Instrument Filter Option: Use Default Filter Read in Instrument Function File

  12. TOA Solar Irradiance Scale Factor