1 / 6

Numatics G3 Fieldbus Electronics

Numatics G3 Fieldbus Electronics. How to Order. What’s different when ordering G3?. With G3 there are three basic configurations in the platform: 1. Main fieldbus manifold with or without I/O 2. Sub-Bus Valve manifold with or without I/O 3. Sub-Bus I/O assembly. 1. Network.

spiro
Download Presentation

Numatics G3 Fieldbus Electronics

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Numatics G3 Fieldbus Electronics How to Order

  2. What’s different when ordering G3? With G3 there are three basic configurations in the platform: 1. Main fieldbus manifold with or without I/O 2. Sub-Bus Valve manifold with or without I/O 3. Sub-Bus I/O assembly 1. Network Main Manifold Sub-bus 2. Sub-Bus Manifold With Valves Sub-Bus Manifold With I/O & Valves 3. I/O Only Sub-bus Sub-bus

  3. G3 Ordering Overview • When ordering a configuration with valves the order format begins with an “AK” number consistent with all previous valve platforms. • The valves associated are listed by station below the AK part number. • Ex: AK3ED00003LSTD Station 1 052BB4Z2ML00061 Station 2 052BA4Z1ML00061 etc. etc. • When it comes to the “G3 electronics” the G3 platform uses a “G3”number similar to the “NX” number used in G2-2 or G2-1. • The primary difference is that the “G3” number indicates the number of I/O modules in the assembly where in previous platforms the NX number indicated the number of I/O points. • Ex: G3EP116R0STD (G3 allow up to 16 I/O modules!) • The I/O modules are listed below the G3 number by station just like in G2-2 or G2-1.

  4. Ordering Example:Fieldbus Valve Manifold Assembly • “AK” (blue) • Includes valve driver and end plates • Valves listed by station from left to right facing the cylinder port side of the manifold • “G3” (Pink) • Includes: clips, node, ARM and sub-bus out module. • List I/O part numbers from right to left facing the cylinder port side of the manifold • Example: • AK3EF00003NDRM • 051BA4Z2MN00061 • 051BA4Z2MN00061 • 051BA4Z2MN00061 • 051BB4Z2MN00061 • 051BB4Z2MN00061 • 051BB4Z2MN00061 • G3PT102D0DRM • 240-205 • 240-212 Assembled

  5. Ordering Example:Sub-Bus Valve Manifold Assembly • “AK” (blue) • Includes valve driver and end plates • Valves listed by station from left to right facing the cylinder port side of the manifold • “G3” (Pink) • Includes: clips, node, sub-bus valve module and sub-bus out module. • List I/O part numbers from right to left facing the cylinder port side of the manifold • Example: • AK3EF00003NDRM • 051BA4Z2MN00061 • 051BA4Z2MN00061 • 051BA4Z2MN00061 • 051BB4Z2MN00061 • 051BB4Z2MN00061 • 051BB4Z2MN00061 • G3DS203D0DRM • 240-207 • Assembled

  6. Ordering Example:Sub-Bus I/O Assembly • No “AK” part number • “G3” part number (pink) • Includes clips • Sub-Bus In • Sub-Bus Out • List I/O part numbers from right to left facing configuration with the display at the top of the assembly. • Example: • G3DS302R0DRM • 240-207 • 240-107 • Assembled