60 likes | 69 Views
Technical engineers in the industry have summarized a list of problems that need attention in the process of installation, use and maintenance of air source floor heating heat pump, as well as specific solutions to these problems.
E N D
Professional Heat Pump Manufacturer since 1999 How to Install & Use an Air to Water Heat Pump for Floor Heating? In modern civil buildings, an air to water heat pump unit used for house heating is becoming more and more popular. Yet, for people who have just come into contact with air source heat pumps, they might meet some difficulties in the installing process, resulting in the low operation efficiency of the system. Technical engineers in the industry have summarized a list of problems that need attention in the process of installation, use and maintenance of air source floor heating heat pump, as well as specific solutions to these problems. Where to Install the Air to Water Heat Pump Unit? Air to water heat pump is a unit that produces heat by absorbing energy from the air, which changes according to the ambient temperature. The higher the ambient temperature, the better the heating effect and the lower the energy consumption. On the contrary, the lower the ambient temperature, the worse the heating effect and the more electricity the unit consumes. Thereby, it is better to install the heat pump unit in a https://www.sprsunheatpump.com
Professional Heat Pump Manufacturer since 1999 sunny place (like balcony) where the unit has a better ventilation effect. How to Operate an Air Source Heat Pump for the First Time? When the air source heat pump is turned on, set the heating temperature button at the zero gear so that the system supplies heating with the lowest water temperature and slow heating will not crack the wall and furniture. An air source floor heating heat pump should not be turned on to a high temperature. First, it is not conducive to the evaporation of water in the wall. Second, the heat will help the neighbors drive the cold because of the heat transfer between houses, which is quite energy-consuming. How to Check the Heat Preservation Effect? Take a constant room temperature of 18℃ for instance. Place a thermometer in the room. After turning off the air source heat pump for 12 hours, if the temperature of the thermometer is reduced by 1℃~2℃ (during the day) and 4℃~5℃ at night. This shows that the heat preservation is good. Otherwise, it indicates that there is air leakage in the house, which needs to be carefully checked. https://www.sprsunheatpump.com
Professional Heat Pump Manufacturer since 1999 How to Use an Indoor Temperature Controller After Installed? A temperature controller installed indoors for air to water heat pump floor heating is to control and regulate the room temperature. As for the water temperature to heat the room, this needs to be controled by the button on the air source heat pump. For example, the temperature button on the air source heat pump is placed at 9 while the temperature controller button is adjusted at 20℃. In this case, the air source heat pump will heat the room with 55℃hot water, so that the room temperature can reach 20℃ as soon as possible. If the temperature button on the air source heat pump is set at 0 and the room temperature is set at 20℃, the air source heat pump will supply heating with 20℃ hot water. Obviously, the former has a fast indoor heating rate, while the latter has a slow indoor heating rate. Therefore, it can be said that with the temperature controller installed, the button on the air source heat pump becomes the adjusting button of the heating rate. Does Air Source Floor Heating Heat Pump Need Antifreezer? Users can be technically guided to add a certain amount of anti-freezing fluid for floor heating with an air source heat pump. Heat pump installers can add a corresponding proportion of anti-freezer according to the size of the floor heating area. https://www.sprsunheatpump.com
Professional Heat Pump Manufacturer since 1999 In order to reduce the operating cost of air source heat pumps, such methods can be tried: when leaving home during the day, you can use low temperature heating; and when returning home, it is necessary to raise the temperature in time to enjoy a comfortable and warm home life. What to Do If Air Source Heat Pump Not in Use in Winter and Summer? In areas below 0℃ in winter, if you are not at home for a short period of time (3 to 5 days), the heat pump unit can be shut down but not the power. Now air source heat pump floor heating units have their own anti-freezing protection function, with automatic shutdown to achieve anti-freezing. The correct anti-freezing measures should be: When no one is at home for a short period of time (less than a week), the unit temperature can be set to the lowest. During this period, air source heat pumps will operate at the lowest temperature. When there is no one in the house for a long time, the water in the floor heating system can be released completely. However, it should be noted that before this operation, please give full consideration to other indoor https://www.sprsunheatpump.com
Professional Heat Pump Manufacturer since 1999 pipelines such as water pipes which will never freeze. When not used in summer, the unit can be shut down when no one is at home for a long time; the power supply can be disconnected and the water in the waterway system can be drained. However, for safety reasons, in the long-term non-residential situation, the power supply must be cut off after the system is drained. How to Drain Away the Water when Cleaning the Filter Net? Close the cold water inlet valve, open the filling valve, turn on the sanitory hot water faucet, and the water can be drained away. Reverse operation can recharge water. Reasons for Low Floor Heating Temperature The heat dissipation of the radiators is insufficient, and this easily occurs in the homes of users who replace radiators and change them to a smaller size, which results in the heat emitted by the radiators not enough to make up for the heat loss of the room. Because the wall is wet, the gasification of the moisture content absorbs a lot of heat, so the room temperature can not go up so quickly. https://www.sprsunheatpump.com
Professional Heat Pump Manufacturer since 1999 The air source heat pump system is turned on and off from time to time. If the system is shut down when the heat is not yet evenly distributed throughout the room, the heat dissipated in the early stage would also be absorbed by the outside because of the heat transfer between households, so it cannot always reach the required temperature. WEBSITE: https://www.sprsunheatpump.com TEL: 0086-20-82181867 PHONE: 0086-18933985223 SKYPE: sprsun.sprsun EMAIL: inquiry@sprsun.com ADD: No.15 Tangxi Road, Yinsha Industrial Park, Xintang, Zengcheng District, Guangzhou,511338, China https://www.sprsunheatpump.com