Scope of the work To develop: • high speed ( ~5 x 10 5 / cm ²s) • high granularity

R&D on Fast Gas Detector Yu. Zanevsky, S. Chernenko, O.Fateev, V. Golovatjuk, L. Smykov, V. Zrjuev, (LHE JINR, Dubna). Scope of the work To develop: • high speed ( ~5 x 10 5 / cm ²s) • high granularity • low mass Gas Detector.

Download Presentation

Scope of the work To develop: • high speed ( ~5 x 10 5 / cm ²s) • high granularity

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. R&D on Fast Gas DetectorYu. Zanevsky, S. Chernenko, O.Fateev, V. Golovatjuk, L. Smykov, V. Zrjuev,(LHE JINR, Dubna) Scope of the work To develop: • high speed ( ~5 x 10 5 / cm²s) • high granularity • low mass Gas Detector In this R&D participate also: GSI (Darmstadt), INFN (Frascati),NC PHEP (Minsk), University (Muenster) CBM Coll. Meeting GSI, February 11-13, 2004

  2. Electron microscope picture of a GEM foil Electron microscope view of a cross-section through one hole GEM Cu / KAPTON / Cu - 5/50/5 mkm Pitch – 140 mkm Hole – 70 mkm Center – 45 mkm C. Altunbas et al. Nucl .Instr. Meth. A 490 (2002), 177-203 CBM Coll. Meeting GSI, February 11-13, 2004

  3. Gas Electron Multiplier (GEM) ЛВЭ ЛВЭ Drift gap – 8 mm Transfer gap – 2 mm Induction gap – 2 mm F.Sauli, Nucl. Instr. Meth. A 461 (2001), 47-54 CBM Coll. Meeting GSI, February 11-13, 2004

  4. Schematic view of double GEM assembly _____________________________________________ DRIFT space 8 mm GEM-1 2 mm GEM-2 2 mm PAD plane CBM Coll. Meeting GSI, February 11-13, 2004

  5. TEST of DOUBLE GEM DETECTOR Xe/C02 80/20 ΔVGEM1 = 450 V ΔVGEM2 = 450 V Fe-55 VD = 3600 V V1U = 1900 V V1D = 1450 V V2U = 950 V V2D = 500 V 8mm 2mm 2mm CBM Coll. Meeting GSI, February 11-13, 2004

  6. Counting plateau _____________________________________________ Ug2=400v CBM Coll. Meeting GSI, February 11-13, 2004

  7. Counting plateau _____________________________________________ Ug2=450v CBM Coll. Meeting GSI, February 11-13, 2004

  8. Rate capability of double GEM detector _____________________________________________ Ug1=400V Ug2=400V CBM Coll. Meeting GSI, February 11-13, 2004

  9. Test signal from PAD ____________________________________________________ t = 4 ns CBM Coll. Meeting GSI, February 11-13, 2004

  10. Signals from PAD of double GEM detector ___________________________________________________ t = 8 ns t = 11 ns Ug1=Ug2=400V CBM Coll. Meeting GSI, February 11-13, 2004

  11. CONCLUSIONS AND TO DO_____________________________________________ Double GEM detector (10 x 10 cm²) is constructed and tested in laboratory conditions with - good efficiency, - high count rate ( ~107 1/cm2 sec ), - low budget material (~ 5% Xo ). We intend to - study the triple GEM detector, - optimize PAD readout to get spatial resolution ~ 0,3-0,5 mm, - decrease an energy in discharge. CBM Coll. Meeting GSI, February 11-13, 2004