300 likes | 636 Views
OPHIR-SPIRICON INC. The True Measure of Laser Performance™. What’s New for 2009. How do I Measure MY Laser?. Power / Energy (Continuous or Pulsed) Temporal Profile (for pulsed lasers) Beam Profile Beam Variations Over Time Beam Wander Size and Shape Power and Energy.
E N D
OPHIR-SPIRICON INC.The True Measure of Laser Performance™ What’s New for 2009
How do I Measure MY Laser? • Power / Energy (Continuous or Pulsed) • Temporal Profile (for pulsed lasers) • Beam Profile • Beam Variations Over Time • Beam Wander • Size and Shape • Power and Energy
What Can We Provide You? • Ophir-Spiricon Offers Instruments for Measuring • Power- from Picowatts to Kilowatts • Energy- from Pico Joules to Hundreds of Joules • Temporal Profile- from sub µs to ms • Wavelength- from 157 nm to 20um • Laser Beam Profiling • Any laser • Any Wavelength ( from soft X-ray to THz) • Any power (from sub nW to over 150 kW) • Any size beam (from micron to meters)
What’s NEW in Power/Energy for 2009? • PULSAR- Multi Channel High Speed USB II Interface • Up to 25,000 Hz on ALL Channels Simultaneously • Now supports ALL SmartHeads • Ideal for Multi-Head Applications
What’s NEW in Power/Energy for 2009? • Vega- NEW COLOR Hand-Held Display • Bright 320X240 Color TFT Display • Optimize your display for various laser glasses • ILLUMINATED KEYS • Easy to use in dim light • New Ergonomic Design
What’s NEW in Power/Energy for 2009? • 100 mm Diameter Pyroelectric Head • 96 mm Clear Aperture for extra large beams • Supplied with removable diffuser for higher powers and energies • Comes with broadband coating
What’s NEW in Power/Energy for 2009? • PE50 Pyroelectric with new diffuser • Rep rates to 3000Hz • TEN TIMES the previous damage limit. • 40J/cm for 1ms pulses • 1J/cm for <100ns pulses
What’s NEW in Power/Energy for 2009? • New High Damage Threshold Coating for Long Pulse Lasers. • FIVE TIMES the previous limit. • 50 J/cm2 for 2ms pulses • 250 J/cm2 for 10ms pulses
What’s NEW in Power/Energy for 2009? • Energy Head specially made for IPL applications • Can be used with and without gels • Easy clean design
What’s NEW in Power/Energy for 2009? • 250W Long Pulse Power Head • Large (33 mm) Aperture • Up to 600J Total Energy • High Energy Density • >400 J/cm2 for >2ms pulses
What’s NEW in Power/Energy for 2009? • 300W Low-Profile Long-Pulse Head • ONLY 20 mm Thick • High Power Density Coating • Up to 150 J/cm2 for 20 ms pulses
What’s NEW in Power/Energy for 2009? • 500W FAN-COOLED Head for Long Pulse Lasers • 65 mm aperture for larger beams • 600J Total Energy • High Energy Density • 200 J/cm2 for 10 ms pulses
What’s NEW in Power/Energy for 2009? • 100/500W Convection-Cooled Head • 75W continuous, up to 500W intermittent. • 65 mm aperture for large beams • Can be used with IPL Sources up to 600 J! • 30 J/cm2 for 10ms pulses
What’s NEW in Power/Energy for 2009? • 1,500 Watt Long-Pulse RP Head • Measures CW Power & PULSE ENERGY • Also Measures Temporal Pulse shape! • Patented “RP” Technology
BEAM PROFILING • The QUANTITATIVE way To Characterize Your Laser • NO Guesswork! • All characteristics of your beam • ISO Beam Widths-No arguments • Easy to use • No operator error!
Laser Profiling Equipment for Lab Use • Compact • USB-II AND FireWire! • From 190-1100 nm and 1450-1625 nm • Can even measure focused spots! • Any Wavelength-all you do is change detector arrays
Laser Profiling Equipment for Lab Use • PYROCAM III • IR to THz Wavelengths • Patented Pyroelectric uncooled detector • Stable, robust, easy to use • FireWire interface
Laser Profiling Equipment for Lab Use • Accessories • Wide range for almost every application • Range extenders for UV • Beam Expanders and reducers • Attenuation kits
What’s NEW in Profiling for 2009? • BEAMGAGE • A whole NEW way of looking at your beam • Totally New Software • Supported by Microsoft VISTA
NEW BeamGage Profiling Software for 2009 • New Functionality • Ability to Test your Beam Calculations with Theoretical Beams! • Better 3D!
What’s NEW in Profiling for 2009? • New Beam Creator lets you see how a Theoretical Beam should appear. • Can be used to ‘calibrate’ beam widths • Will Revolutionize the Science of Spatial Beam Profiling!
What’s NEW in Profiling for 2009? • LBS-300 Integrated Focused Spot SYSTEM • Measures focused spots as small as 60 um • UP to 400 W total power • Works with short focal length lenses! • Image your FOCUSED SPOT!
What’s NEW in Profiling for 2009? • LARGE Format Profiling Camera • 24 mm X 36 mm Array • 11.2 Mpixels • FireWire Interface • 190 nm to 1100 nm range • Directly Image Large Beams!
What’s NEW in Profiling for 2009? • BeamCube Integrated Beam Characterization SYSTEM • Measures spatial profile, focal spots, temporal pulse shape and power all in one unit! • UP to 150 W total power • Know your Beam Totally!
What’s NEW in Profiling for 2009? • M2-200s • FAST new Smaller M2 system • Industrial design-even for continuous use • M2 in as little as 45 seconds! • TRUE ISO 11146!
What’s NEW in Profiling for 2009? • SP 503/620 USB-II MiniCameras • Built-in Pulse Sync operation • Small footprint • High density Pixels • Lower cost
Industrial Beam Profiling Equipment • For 400-1100 nm Lasers • Power up to 4 kW • Integrated systems • Some measure power and temporal profile as well as Beam Profile
Industrial Beam Profiling Equipment • Now for high power CO2 as well as Near IR applications • Up to 48 mm diameter beams • Up to 8 kW continuous power • Can be permanently installed for on-line beam monitoring • Totally transparent to the process
SUMMARY • New Technology Makes Diagnostics Easier • Results in: • More Reliable Operation • Better Beam Quality • Less Waste • Higher Profits
For More Information… • Contact your local representative • Find us on the web: • www.ophir-spiricon.com THANK YOU FOR WATCHING