An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. XXX CONGRESSO NAZIONALE SICP VERONA 8-10 MAGGIO 2008 SOSTITUZIONE ARTICOLARE DELLA METATARSO-FALANGEA INDICAZIONI E ALTERNATIVE CHIRURGICHE P. RONCONI- F. CANCILLERI - E. ARATI

  2. Numerosi sono stati i modelli protesici per la sostituzione articolare metatarsofalangea ed in particolare della prima articolazione

  3. Diversi i materiali usati: leghe in acciaio , titanio, polietilene, siliconici di varia natura ecc.

  4. Il trattamento chirurgico segue protocolli standard che sono condizionati dallo stato evolutivo della malattia ( F. Malerba, F. De Marchi 1995)

  5. Si possono distinguere in Tecniche : 1-Conservative 2-Demolitive 3- Artroplastiche con interposizione

  6. 3- Artroplastiche con interposizione: A- Spaziatori permanenti B- Spaziatori temporanei C- Spaziatori riassorbibili D- Protesi articolari E- Emi-Impianti

  7. Gli emi-Impianti ( Si comportano come spaziatori permanenti mantenendo una buona articolarità pur presente una degenerazione cartilaginea in sede di testa metatarsale ) Follow-up di oltre 20 anni con 95% di ottimi risultati (Townley)

  8. Tecnica personale: Osteotomia decompressiva ed emi-impianto Perchè osteotomia ed emi-impianto?

  9. Nell’alluce rigido o nell’alluce valgo rigido si assiste a: 1- Ipermetria metatarsale (Spesso) 2- Alterazione dell’asse di rotazione della I MF 3- Elevazione dinamica del I metatarso che determina la triade:

  10. Pinch Callus Bomp dorsale Alluce “ Autostop”

  11. CONSEGUENZE Effetto negativo sull’asse di rotazione della I MF che porta a rigidita’ fino al blocco articolare ,conseguente deambulazione varizzante e sovraccarico funzionale delle teste metatarsali vicine

  12. Alterazione del rapporto Retro-avampodalico

  13. Per questi motivi abbiamo apportato una modifica alla tecnica chirurgica del “puro “ emi-impianto eseguendo una osteotomia obliqua con 4 gradi di liberta’ P. Ronconi e coll. -.Weil Osteotomyof the first metatarsal ( Modified by Ronconi) for the correction of Hallux Rigidus) Abstract 2° Congress EFFAS , Basilea 1996 ;33 P. Ronconi e coll. . Distal oblique osteotomy of the first metatarsal for the correction of hallux limitus and rigidus . J. Foot Surg. , 2000; 39:154-160

  14. Possibilita’ di spostamento spaziale della testa metatarsale con osteotomia obliqua (4 gradi di libertà: abbassamento,arretramento,lateralizzazione e rotazione)

  15. PROCEDURA CHIRURGICA • SHAVING ARTICOLARE

  16. PROCEDURA CHIRURGICA • DISALLINEAMENTO ARTICOLARE • TESTA MT ELEVATA • RIGIDITA’ ARTICOLARE

  17. PROCEDURACHIRURGICA • OSTEOTOMIA OBLIQUA CON 4 GRADI DI LIBERTA’

  18. PROCEDURA CHIRURGICA • VALUTAZIONE ARTICOLARITA’ MF DOPO OSTEOTOMIA

  19. PROCEDURA CHIRURGICA OSTEOSINTESI

  20. PROCEDURA CHIRURGICA • OSTEOTOMIA ECONOMICA BASE FALANGE

  21. PROCEDURACHIRURGICA • MISURA PERIMETRALE PER ALLOGGIAMENTO EMI-IMPIANTO

  22. PROCEDURACHIRURGICA APPLICAZIONE FILO GUIDA E FRESATURA

  23. PROCEDURA CHIRURGICA • APPLICAZIONE EMICOPPA DI PROVA E VALUTAZIONE ARTICOLARITA’ • RIMOZIONE EMICOPPA DI PROVA

  24. PROCEDURA CHIRURGICA • ALLOGGIAMENTO EMIPROTESI

  25. PROCEDURA CHIRURGICA • VALUTAZIONE NUOVA ARTICOLARITA’ • INSERIMENTO INTRA-ARTICOLARE FATTORI DI CRESCITA

  26. CASISTICA DAL 23/03/2007 AL 30/12/2007: N. CASI:12 (F:11 -M: 1) RANGE ETA’: 45-75 GRADO II-III: 6 GRADO III: 6 PREGRESS. INTERV.: 2 VALGO-RIGIDO: 6 SOLO EMIMPIANTO: 3 OSTEOTOMIE MT LAT.: 5 CORREZIONE RETROPIEDE: 1

  27. Alluce rigido con rapporto retro-avampodalico alterato

  28. Controllo 27-03-2008

  29. Valgo rigido op 3-10-07 Controllo 5-3-2008

  30. Valgo rigido op 3-10-07 Controllo 5-3-02008

  31. Varo iatrogeno

  32. Varo iatrogeno

  33. CONTROINDICAZIONI • ARTROPATIE INFIAMMATORIE • GRAVE ARTROSI SESAMOIDEA • INFEZIONI • FALLIMENTI NELLE ARTRODESI

  34. Risultati Con lo score Koenig modificato : Considerando il breve periodo di riferimento della casistica si è proceduto ad una valutazione clinico – obiettiva preliminare esaminando alcuni parametri di riferimento A-Grado di soddisfazione del paziente B- Sintomatologia dolorosa C- Limitazione attività lavorativa D- Deambulazione E- Uso di calzature F- Rdx di controllo

  35. Koenig score modificato - 9 casi (risultato Ottimo): No dolore Buona funzione MTP1 ( Range > 30 ) Marcia normale Non segni di scollamento e o mobilizzazione protesi - 2 casi ( risultato Buono): Sono quelli con assenza di dolore , soddisfatti ma con funzionalità ridotta ( Range <= 30 ° ) - 1 caso ( risultato scarso) Con dolenzia alla deambulazione

  36. Conclusioni • Questa metodica per la sua versatilita’ di impiego puo’ essere usata in tutti quei casi dove bisogna : • 1- Abbassare la testa metatarsale ( ricentramento articolare) • 2- Arretrare la testa metatarsale ( Nelle ipermetrie) • 3- Migliorare il rapporto retro-avampodalico • 4- Aprire o chiudere l’IMA ( osteotomia di apertura o di chiusura) • 5- Migliorare l’orientamento della testa metatarsale (Sfrutta il 4° grado di libertà (la rotazione) • 6- Aumentare il range of motion MPJ1 • 7-Preservare il Bone Stock articolare che in caso di insuccesso consente di poter ricorrere ad un impianto protesico o ad una artrodesi

  37. Conclusioni • INFINE DESIDERIAMO EVIDENZIARE CHE LA TECNICA NON E’ • DIFFICOLTOSA E CHE LA CURVA DI APPRENDIMENTO E’ ABBASTANZA BREVE : DUE TRE IMPIANTI

  38. GRAZIE