Hospital Central Gas Supply Systems. Simplex MMR. - Small cottage hospitals, veterinaries, dentists, third source of supply etc. - Suitable when automatic change over is not a demand - Connections for 3 high pressure hoses - Gaslarm C44 - 27-30 m3/h - CE-marked according to EN737-3.
E N D
Simplex MMR - Small cottage hospitals, veterinaries, dentists, third source of supply etc. - Suitable when automatic change over is not a demand - Connections for 3 high pressure hoses - Gaslarm C44 - 27-30 m3/h - CE-marked according to EN737-3
Manifold MC25 • - Small to intermediate sized hospitals, Large hospitals for N20 • - (Medical Breathing) O2, Air, N2O, CO2, N2 and Argon. • - 25 Nm3/h (O2), 17 Nm3/h (N2O) • - Gas Cylinders/ Cylinder Bundles
Manifold MC25 - 2-stage control - Semiautomatic Manifold - Service without interruption of the gas flow - Gas Alarm C44 - Slave panels: Gas Alarm C44, Connect from Relays - CE-marked according to: EN737-3
Manifold MM90 Auto & Semiauto - Intermediate to large sized hospitals - (Medical Breathing) O2, Air, N20 - 90 m3/h (O2) - Gas Cylinders/ Cylinder Bundles - CE-marked according to: EN737-3
Manifold MM90 Auto - LOX backup - Automatic Change of Operating side, Automatic Manifold - Service without interruption of the gas flow
Manifold MM90 Semiauto - LOX-backup - Manual Change of Operating side, Semiautomatic Manifold - Service without interruption of the gas flow
Stabilizer MC80 - For all medical gases - Inlet from LOX-tank and from Manifold - Service and repair without interrupting the flow - Sometimes one for every building - Normal operation, use only one regulator, one for backup - 80 Nm3/h (with dP2<0,3 bar) - Adjustable outlet pressure (P2=3-7 bar) - Inlet and outlet 22 mm (Int.) - CE-marked according to: EN737-3
Stabilizer MC150 - Same basic design and outer appearance as MC80 Stabilizer - Service and repair without interrupting the flow - Suitable for double LOX- systems - Normal operation, use only one regulator - 150 Nm3/h (with dP2<0,3 bar) - Variable outlet pressure, (P2=3-7 bar) - Inlet and outlet 35 mm (Int.) - CE-marked according to: EN737-3
Gas Alarm C44 - Gas alarm intended for Manifolds (MM90, MC25 and Simplex MMR) and Pressure Watch - Backup battery (30 min) - Mute (15 min) /Test button - Alarm signal according to EN475. - Optical and audible signal - Adjustable audible signal - 4 Channels = 4 alarm points - EMC Approved - CE-marked according to EN737-3, SIS HB370, EN60601
Gas Alarm C44 IN-SIGNAL: - Pressure switches, contact gauges, relays or any other type of switch (e.g. light switch) OUT-SIGNAL: - Connection by relays 1. Can be connected to a PC (PLC). Using the PC as a slave panel 2. To another Gas Alarm C44
4-20 mA Alarm System -Can send the signal a long distance - Connect the transmitters directly to PLC (PC). - For local alarm; connect PLC to Gas Alarm C44 - 4-20 mA is the signal that most used in hospitals for other alarms - Specially designed for usage with high pressure oxygen - Accuracy 1% of FS better accuracy than Pressure Switches - Can be fitted to all products (MM90, MC25, Simplex MMR, Line regulators, Pressure Watch) - Pressure port G1/4” - 0-16 bar, 0-25 bar and 0-250 bar versions - CE-marked
High Pressure Hoses - 100% steel. - Gas-specific connection to all kind of cylinders - Length: 1250 or 2000 mm - Product life 5 years - Maximum allowed operating pressure 230 bar - Pressure tested at 345 bar - Safety wire - O2, N20, Air, CO2, Nitrogen - CE-marked according to: ISO 2196, EN13221
Medical Piping System - Safety Valve for pipe system - Evacuates if the pressure exceeds 6,8 bar - Evacuates 130 m3/h - 2 models, one is intended to be mounted immediately after Simplex MMR - CE-marked according to EN737-3
Medical Piping System - Shut-off Valves - Safety and service reasons - Service free - Can be locked - Degreased for oxygen service - PN 40 class - DN10, 15, 25, 32 and 40
Emergency Shut-Off Valve Box - For safety and service reasons - Usually outside every ward. In some wards outside every room. - Exposed installation / Recessed installation - Pipes turning - 1-5 valves - Sealed front - Pressure and leak tested - Service free valves - CE-marked according to EN737-3
Gas Outlets Nordic (MC70 and MINI) - Exposed / Recessed /Bed head (Panel) Installation - Service valve - Quick Coupling - Gas specific (MINI parts can be mixed up) - O2, N20, Air, Vacuum, Gas exhaust, Instrumental Air, N2, CO2 - CE-marked according to EN737-3, EN737-1, ISO9170-1, SS8752430
Gas Outlets Afnor - Exposed / Recessed /Bed head (Panel) Installation - Service valve - Quick Coupling - Gas specific - O2, N20, Air, Air 8 bar, Vacuum, N2, CO2 - CE-marked according to EN737-3, EN737-1, NFS 90.116
Gas Outlets DIN • - Exposed / Recessed /Bed head (Panel) Installation • - Service valve • - Quick Coupling • - Gas specific • - O2, N20, Air, Air 8 bar, Vacuum, N2, CO2 • - CE-marked according to EN737-3, EN737-1